Term
Diving Umbilicals,Common components: |
|
Definition
-Gas supply hose -Communication wire -Pneumofathometer -Lifeline |
|
|
Term
Diving Umbilicals,Optional components: |
|
Definition
-Hot water supply -Video cable -Power cable for lighting etc. -Just about anything |
|
|
Term
|
Definition
-Industry standard – taping -Twisted assembly -Whipped and/or tie wrapped -Sheathed |
|
|
Term
|
Definition
-Visual inspection *Hose fitting *Communication connectors *Tape and/or whipping -Rinse with fresh water -Blow through -Test communications -Coil and hang up |
|
|
Term
|
Definition
-Internal wash/rinse -Pressure test *1½ to 2 times working pressure -External inspection *Fitting *Communication connectors *carabineer |
|
|
Term
O. Reg 629/94 The diving supervisor for a diving operation shall ensure that any breathing mixture supply line used in surface supplied diving... |
|
Definition
-is adequate; -has an internal diameter sufficient to permit adequate flow rates and pressures; -is protected in a way that ensures against damage at the dive site; and -is protected against kinking |
|
|
Term
Presently three types of diving hose available for diving use: |
|
Definition
-Gates -Aqualite -Barfell Hose |
|
|
Term
|
Definition
-Air, Oxygen, HeO2 compatible -No chemical off gassing -Kink resistant |
|
|
Term
|
Definition
-Black synthetic rubber tube -Reinforced with 2 fiber braids -Rubber treated to prevent blisters -Abrasion & oil resistant cover *Resists most chemicals and solvents found in contaminated water -Temperature range: - 40°F - 200°F -Length change @ working pressure 2-4% -3 diameters available 3/8” 1125 psi max. working pressure 1/2” 1000 psi max. working pressure 3/4” 750 psi max. working pressure Safety factor 4:1 -Negatively buoyant except ¾” diameter hose -Standard maximum length 1000’ -No splicing of gas hose |
|
|
Term
Aqualite Features: By Jacques cable systems. |
|
Definition
-Tube and cover extruded in Aquathane, a specially compounded – polyurethane -Temperature range of -40° - 60° C -Does not deteriorate with age, remains flexible -Available in; 1/8”, 1/4”, 3/8” & 1/2” diameters -Maximum working pressure; -3/8” – 500 psi -1/2” – 350 psi -Safety factor 4:1 – burst pressure 2000 psi -Best advantage over Gates; -Buoyant in Salt and Fresh water |
|
|
Term
Barfell Diving Hose are not to be used: |
|
Definition
NOT TO BE USED IN CLIMATES WHERE TEMPERATURES MAY BE BELOW 0° C (32°F). |
|
|
Term
Barfell Diving Hose features: |
|
Definition
-Cover and tube – extruded PVC -Polyester filament reinforcementEO Trailer connectors Marsh Marine Direct wire Banana Plugs -Internal diameter 10mm -External diameter 16.8 mm -Burst pressure is 1524 psi @ 68°F -Recommend 4:1 Safety factor -This hose will break in freezing temperatures. |
|
|
Term
Pneumofathometer Hose should be: |
|
Definition
-Should be of a different colour -Rated to 250 psi -Flexible -Be able to take standard fittings -Should be of a continuous length, but maybe spliced |
|
|
Term
Hot Water Hose should be: |
|
Definition
-Should be kink resistant -Heat compatible -Can be added to or spliced -½” minimum internal diameter -Approximately 350 psi water pressure |
|
|
Term
Breathing hose and Pneumo hose should be: |
|
Definition
-Hose barb (2” – 2 ½”) Barbed fitting -Re-useable or swaged *JIC or 9/16” x 18 Oxygen fitting *JIC preferred by Ministry for breathing air *All fitting should be brass or stainless steel |
|
|
Term
Hot Water Hose Fitting features: |
|
Definition
-Quick connect on diver’s end -NPT male on topside end -All fittings should be brass or stainless steel |
|
|
Term
Communication Wire features: |
|
Definition
-4 conductor – min. 18 gauge -Stainless steel braided reinforcement -Polyethylene water block -Most common is PVC covered |
|
|
Term
List different Communication Connectors: |
|
Definition
-EO -Trailer connectors -Marsh Marine -Direct wire -Banana Plugs |
|
|
Term
Maintenance Daily Visual inspection Breakdown: |
|
Definition
-Hose fitting -Communication connectors -Tape and/or whipping |
|
|
Term
Maintenance Yearly: External inspection |
|
Definition
-Fitting -Communication connectors -carabineer |
|
|
Term
Gates 33HB Reinforced with |
|
Definition
Reinforced with 2 fiber braids |
|
|
Term
Gates 33HB is ______ _______ to prevent blisters |
|
Definition
|
|
Term
Gates 33HB has a ________ & ___ resistant cover |
|
Definition
|
|
Term
Gates 33HB, Resists most... |
|
Definition
chemicals and solvents found in contaminated water |
|
|
Term
Gates 33HB, Temperature range: |
|
Definition
|
|
Term
Gates 33HB, Length change @ working pressure |
|
Definition
|
|
Term
Gates 33HB, 3 diameters available: |
|
Definition
3/8” 1125 psi max. working pressure 1/2” 1000 psi max. working pressure 3/4” 750 psi max. working pressure |
|
|
Term
Gates 33HB is __________ _______ except _” diameter hose |
|
Definition
Negatively, buoyant, except ¾” diameter hose |
|
|
Term
Gates 33HB, Standard maximum length: |
|
Definition
|
|
Term
Aqualite, Tube and cover extruded in: |
|
Definition
Aquathane, a specially compounded – polyurethane |
|
|
Term
Aqualite, Temperature range of |
|
Definition
|
|
Term
|
Definition
deteriorate with age, remains flexible |
|
|
Term
|
Definition
1/8”, 1/4”, 3/8” & 1/2” diameters |
|
|
Term
Aqualite, Maximum working pressure; |
|
Definition
3/8” – 500 psi 1/2” – 350 psi |
|
|
Term
|
Definition
4:1 – burst pressure 2000 psi |
|
|
Term
Gates 33HB, Safety factor |
|
Definition
|
|
Term
Aqualite, Best advantage over Gates; |
|
Definition
Buoyant in Salt and Fresh water |
|
|
Term
Barfell Diving Hose, Cover and tube has: |
|
Definition
|
|
Term
Barfell Diving Hose, _________ filament reinforcement |
|
Definition
|
|
Term
Barfell Diving Hose, Internal diameter |
|
Definition
|
|
Term
Barfell Diving Hose, External diameter |
|
Definition
|
|
Term
Barfell Diving Hose, Burst pressure is: |
|
Definition
|
|
Term
Barfell Diving Hose, Recommend _:_ Safety factor |
|
Definition
|
|
Term
Pneumofathometer Hose; should be a different ______ |
|
Definition
|
|
Term
Pneumofathometer Hose; should be a rated to ___ psi |
|
Definition
|
|
Term
Pneumofathometer Hose; should be a ________ hose |
|
Definition
|
|
Term
Pneumofathometer Hose; should be a able to take: |
|
Definition
|
|
Term
Pneumofathometer Hose; should be of a _________ length, but maybe _______ |
|
Definition
Should be of a continuous length, but maybe spliced |
|
|
Term
Hot Water Hose, should be ____ resistant |
|
Definition
|
|
Term
Hot Water Hose, should be ____ compatible |
|
Definition
|
|
Term
Hot Water Hose, can be _____ to or ______ |
|
Definition
Can be added to or spliced |
|
|
Term
Hot Water Hose, _" minimum internal diameter |
|
Definition
½” minimum internal diameter |
|
|
Term
Hot Water Hose, Approximately ___ psi water pressure |
|
Definition
|
|
Term
Breathing hose and Pneumo hose barb _" - __" barbed fitting |
|
Definition
|
|
Term
Breathing hose and Pneumo hose fittings should be _____ or __________ _____ |
|
Definition
All fitting should be brass or stainless steel |
|
|
Term
Hot Water Hose Fitting, Quick connect on: |
|
Definition
Quick connect on diver’s end |
|
|
Term
Hot Water hose fittings should be _____ or __________ _____ |
|
Definition
All fittings should be brass or stainless steel |
|
|
Term
Communication Wire, 4 conductor – min. __ guage |
|
Definition
|
|
Term
Communication Wire, __________ _____ braided reinforcement |
|
Definition
Stainless steel braided reinforcement |
|
|
Term
Communication Wire, ____________ water block |
|
Definition
|
|
Term
Communication Wire, Most common is ___ covered |
|