Shared Flashcard Set

Details

Training Bulletins
Training Bulletines
50
Bartending
Professional
07/24/2014

Additional Bartending Flashcards

 


 

Cards

Term
According to TB #97 what are the 3 ways a person can escalate or de-escalate a potential confrontation?
Definition

Actions

Demeanor

Attitude

Term
According the TB#97 what is the "key" to dealing with people?
Definition
PROPER communication
Term
TB#97 says that _______ is the "most meaningful way" in which we communicate with the public?
Definition
Non-Verbal or body language
Term
TB #97 says the message that we send to others is often  __________% content, __________ Voice and ___________ NON VERBAL
Definition

7-10%

 

33-40%

 

50-60%

Term

TB #97

Nonverbal communication is often unplannes and can have more impact that verbal communication. It is not only reliable but can show _____?

Definition
attitude
Term

TB #97

What are the five categories of non-verbal communication?

Definition

Voice signals

Body signals

Object signals (outward appearance)

Space Signals (personal space)

Time Signals (being on time)

 

Term

TB #97

It has been shown that an intimate distance reserved for only loved ones is between ____ while a personal distance for good friends is ______.

Definition

6-18"

 

18"-4'

Term

TB 97

 

The Social distance for acquaintances is between _________

Definition
4-12'
Term

TB 97

The Public distance for strangers is ______?

Definition
12 feet
Term
According to the TB 94 Asbestos handout any open flame for lighting and decour shall not be installes in any area within ____ Feet of any combustible material.
Definition
5 feet
Term
According to the handout on TB#94 what is the definition of Asbestos Containing Material??
Definition
Any material containing .1 percent or more dry weight asbestos.
Term

According to the handout on TB#94 the

PRIMARY PURPOSE of a _______ is to maintain a negative atmosphere in the containment area.

Definition
Negative Air Machine
Term
According to the handout on TB#94 the reapplication of an approved fire protective coating is called a ?
Definition
Respray
Term

According to the handout on TB#94 what is the minimum amount of asbestos removal requiring a permit?

 

Who is exempt from this project permit?

Definition

100 square feet of ACM

 

Any residential structure of 4 Units or less

Term
According to the handout on TB#94 how long is a asbestos abatement permit good for?
Definition
180 days.
Term
According to the handout on TB#94 who collects the fees for a asbestos permit and where?
Definition

collected by FD sucka!!

 

Engineering unit

Term
According to the handout on TB#94 how many PLOT PLANS showing the size undergoing abatement are required and what size shall they be?
Definition

3 copies

8 1/2 x 11"

Term
According to the handout on TB#94 how many days prior to the abatement do you need to obtain the permit?
Definition
10 calendar days
Term
According to the handout on TB#94 what is the asbestos permit fee?
Definition
flat rate fee of $300 plus 9 cents per square foot over 1,000 square feet.
Term

According to the handout on TB#94 how many completed copies of the SCAQMD forms shall be submited to the fire department?

A seperate letter shall be mailed by the contractor to the FD within _____ hours of the completion of the project.

Definition

3

48 hours

Term
According to the handout on TB#94 where shall the contractor keep the abatement plans upon completion? How often shall they be updated?
Definition

3 ring binder in the FIRE CONTROL ROOM, SECURITY DESK or an approved location.

 

Updated DAILY

Term
According to the handout on TB#94 any plastics used in the abatement process need a MSDS. Tape and Plexiglass viewing ports are an exception unless ???
Definition

The ports are larger then 4 sq ft

and

total aggregate area of < 40 sq ft.

Term

According to the handout on TB#94 how many clearly marked exits shall be maintained from each floor during the process?

 

How do you identify a COVERED EXIT?

Definition

2

 

Outlined in RED Duct tape and a cutting device kept adjacent to the door also surrouned in a square of RED duct tape.

Term
According to the handout on TB#94 what is required in a multi-story building when >25% of the floor area is undergoing abatement?
Definition

1) Permitted on a floor by floor basis provided NO 2 consecutive floors are undergoing abatement.  A maximum of EVERY OTHER FLOOR, up to a total of 3 floors out of 5 is permitted.

2) a minimum of 5 clean BUFFER floors must seperate each group fromt he next floor group.

Term
According to the handout on TB#94 what is the maximum total floor space allowed to be under active abatement in a single story house?
Definition
maximum of 50%
Term
According to the handout on TB#94 in multistory/single story buildings what size ASBESTOS ABATEMENT sign must be placed in the Fire Control Room next to the Annunciator Pannel?
Definition
20"x14" RED,BLACK,WHITE
Term

According to the handout on TB#94 in multistory buildings what size sign for the

FLOORS INVOLVED must be placed in the Fire Control Room next to the Annunicatory panel.

Definition
12"x12" with 3"high and 1/2" wide lettering on a contrasting background
Term
According to the handout on TB#94 where to the Asbestos Abatement and Floors Involved signs get posted other then the Fire Control Room?
Definition

1) Each landing in each stairwell which leads to any floor undergoing abatement.

2) Begining 2 floors below the affected floor

3) On the floor above the affected floor.

Term

According to the handout on TB#94 what is the mimimum size fire extinguisher allowed? 

 

Where shall they be placed?

What are the distances?

What is the Exception to this?

 

Definition

1) 4A/60BC

2) Each Electrical Panel & Each corner of the work area

(5 ft of external entry from work area, 5Ft external area from clean room.Maximum travel distance of 75Ft)

3) area is less than 1,000 square feet

Term
According to the handout on TB#94 a minimum of ____ TELEPHONES shall be provided for contacting emergency personnel in containment areas >1000sq ft. SHALL be located in the CLEAN  ROOM
Definition
1
Term
According to the handout on TB#94 how many LINEAL feet from the clean room shall the telephone be.
Definition
100
Term
According to the handout on TB#94 all sprinkler heads shall remain active, however they may be covered with a ______ or LESSS plastic bag.
Definition
.003
Term
According to the handout on TB#94 all existing fire alarm boxes and communications remain in place. If covered in plastic it must be surrounded in a RED duct type square with the cutting device also in a RED square. They shall be clearly marked with a sign _________
Definition
3" high and 1/2" wide on a contrasting background
Term
According to the handout on TB#94 if a fire and life safety system has been dissconnected it requires acceptance from the Fire Department and _______ upon RENCONNECTION.
Definition
Building and Safety
Term
According to the handout on TB#94 what is required by BUILDING AND SAFETY if the containment area impedes normal operation of elevators.
Definition
an additional TEMPORARY elevator recall smoke detector. Tested by the LAFD
Term

According to the handout on TB#94 how many protective suits are required?

What size shall they be?

How is the box they're kept in identified?

Definition

5

XLG

RED BOX identified with WHITE 3" letters stating FIRE DEPARTMENT USE ONLY

Term
According to the handout on TB#94 an area thatis contaminated shall be visible from a VIEWING PORT from an UNcontaminated area. What size are the ports?
Definition
18 inches x 18 inches
Term
According to the handout on TB#94 a sign reading NEGATIVE AIR MASTER SHUTT-OFF is over the switch or switches in a noncontaminated room with a sign of what size?
Definition
3" high and 1/2" wide
Term
According to the handout on TB#94 the permit for the negative air equipment is provided by?
Definition
Department of Building and Safety
Term
According to the handout on TB#94 all bagged asbestos shall be removed and disposed of ______________? or 24-Hour period if work is continuous.
Definition
at the end of each working day
Term

According to the handout on TB#94 

How many days after receipt of the final clearance shall the RESPRAY be completed?

Definition
15 days
Term

According to the handout on TB#94

All asbestos abatement projects REGARDLESS OF SIZE require a 

Definition

on site supervisor designated as a

SAFETY COORDINATOR

Term

According to the handout on TB#94

If the Asbestos project is 1,000 sq ft or more a member is required for __________ if the

fire protective coating or structural members are removed.

 

Definition
Fire Safety Watch
Term

According to the handout on TB#94

How often must the Fire watch inspect every area of the work site?

Definition
minimum of 30 minutes after cessation of work.
Term

According to the handout on TB#94 if there is functioning fire detection system the F.W. may be discontinued ___________.

If there is no functioning fire detection system the F.W. shall be maintained on a ______

Definition

30 minutes after completion of each work day.

 

24 hour basis

Term

According to the handout on TB#94

Any work requiring use of an open flame shall require a FIRE WATCH standing by with a ________ size extinguisher.

Definition
4A/60BC
Term

According to the handout on TB#94

Smoking is NOT PERMITTED in a asbestos abatement are or within ____ feet of the area.

Definition
25 feet
Term

According to the handout on TB#94

All PARADE FLOAT decorations that are _______ in thickness or less shall be flame retardent.

Definition
1/8 inch thickness
Term

According to the handout on TB#94

PARADE FLOATS

OPEN FLAME=prohibited unless approved by?

Smoke producing devices must be _______ type.

ALL FLOATS must have a ______ extinguisher readily accessible by the OPERATOR

 

Definition

Fire Chief in writing

NON heating

2A/10BC

Supporting users have an ad free experience!