IF CCW, fix CCW
Motor Winding - maximize CAN Ventilation near that RCP. Available CFCUs in high speed.
Loss of seal injection AND < 2.5 gpm leakoff on any RCP - restore seal injection or raise VCT press >30 – 50 psi (prevents flashing in the line, even if there is cooling to TBHX)
Leakoff < .8 gpm or slowly approaching 6 AND temps are stable or lowering - ensure injection ≥ 9 gpm, commence orderly S/D, stop RCP w/in 8 hrs.
#2 Seal leakage by RCDT leak rate
Ensure injection > 9 gpm
Leakoff .5 - 1.1 gpm - continue operation
>1.1 - orderly S/D and stop RCP w/in 8 hrs
Total leak off from #1 & #2 seals
> 8 gpm - Attachment 2 (stopping RCPs)
Between 6 and 8 and temps not stable-Attachment 2
Between 6 and 8 and temps stable - orderly S/D within 8 hrs after rising > 6 gpm
Thermal Barrier HX
Isolate and find w/ CC130s
|