Term
CCW Purpose:
Definition
Provide reliable cooling for potentially Rad Safety and NSR loads during all operational modes and a DBA. Closed loop system provides an additional barrier  to prevent direct release of radioactivity to Delaware River.
Term
CCW Design Basis:
Definition
  1. Transfer heat from SR/NSR loads to SW during normal operations and DBAs. CCW pressure is < SW pressure. CCW design pressure is 150 psig @ 200 F, except in Containment- RCP thermal barrier 650F and 2485 psig.
  2. ESF System: 2 independent parallel trains consisting of one Pp and one HX. Each train Powered by Class 1E and Diesel. Each train capable of bringing the plant to cold Shutdown following postulated LOCA, Concurrent with LOP and DBA earthquake
  3. Sized such that SW at 90F, will make CCW <99F at all times.
  4. Provided with Design features to detect leakage
  5. RCP thermal barrier Leak detection isolation
  6. CCW Surge Tank relief valve can hold postulate RCP thermal Barrier leak to CCW
  7. Relief valves provided to CCW HX to prevent overpressurization due to thermal expansion
  8. Containment Auto isolation Valves
  9. Designed for Shutdown Concurrent with MCR evacuation (operation from HSD Panels)
Term

CCW Surge Tank:

 

Purpose and Specs

Definition

Provides NPSH to CCW Pps, Accommodates volume of RCS entering the CCW for 3.5 minutes following a RCP thermal barrier rupture, Accommodates System Surges and Provides means for chemical mixing.

  1. 2000 gallons max, normal 50% full, 2 level detectors
  2. Internal Baffle at 37.5%
  3. Make Up Water provided by DR (via DR107) or alternate source-PWST, fill valves are CC145/146
  4. Vented to Aux Bldg Exhaust Filter Inlet Header via CC149, CC149 auto closes on RMS 17 a/b high rad or failed monitor alarm
  5. Tank Relief Valve CC147, set point 100 psig, passes > 285 gpm to  contaminated floor drains and then WHUT.
Term

CCW Pps:

 

Purpose and Specs

Definition

Circulate hot CCE thru CCW HX, cooled by SW. The cooled CCW is then supplied to all heat loads.

3 pps-

  • 21 in 21 HX Room powered by A 4 KV VB,
  • 22/23 in 22 HX Room powered by B and C 4 KV VB respectively
  • Centrifugal PP max- 4600 gpm @ 200 psig, min 1100 gpm 
  • Suction Header relief valve CC138, setpoint 150 psig
  •  Normal Operation is two Pps running and one in auto standby.

Auto Starts:

Low Header Pressure, <70psig

SEC Mode 2 blackout auto sequencer

 

Auto Trips:

Vital Bus Overload

Vital Bus Diff

SEC Trip Signal

Mtr Overcurrent

 

SEC:

Mode I, if in auto will remain in auto

 

Mode II, III, IV take to manual and Pp will restart as needed.

Term

CCW HX:

 

Purpose

Definition
Modes 4,5,6 transfers heat from RHR HX to SW. Normal Ops (Modes 1,2,3) transfers heat from NSR loads, Accident cool RHR HX and seal coolers of SR Pps.
Term
CCW Safety Related Loads
Definition
  • RHR HX
  • RHR Mechanical Seal HX
  • SI PP Mechanical Seal HX
  • Charging Pp (23) lube oil cooler/speed changer
Term
CCW Non-Safety Related Loads
Definition
  • SFP Cooling HX
  • LTDN HX
  • Seal Water HX
  • Waste Gas Compressor
  • Excess LTDN HX
  • Sample System HX
  • Pass Racks
  • SGBD RMS
  • RCPs- Upper Motor Cooler/ Lower Motor Cooler/ Thermal Barrier HX
Term
CCW Sources of Inleakage:
Definition
    System Pressure is greater than CCW pressure
  1. RCP Thermal Barrier
  2. Excess LTDN HX
  3. LTDN HX
  4. RHR HX
  5. Mechanical Seals of Running Pps

 

Term

CC149 CC Surge Tank Vent Valve

Interlocks

Definition

Auto Close on Hi Rad from R17A/B or RMS failure

 

Close on Loss of Control Air and

 

Loss of Power (28/125 V DC)

Term
CC-131 RCP Thermal Barrier Discharge Flow Interlocks
Definition

Containment Isolation Vlv

 

Auto Close if flow is > 175gpm for > 4 seconds (for leak isolation, normal flow is 160 gpm), this will mannually override the auto functions of this valve.

 

Term
CC215 and CC113 Excess LTDN HX Interlocks
Definition

CC215(inlet to HX), CC113 (Outlet from HX) 

 

Auto Close on: 

Loss of Air

Loss of 28/125V DC

Containment Phase A

Term
CC71 LTDN HX Temperature Control Interlocks
Definition

Safety Related  AOV

"Auto" maintains 100F CVCS LTDN

"Manual" adjust temperature by pressing increase/decrease bezels in MRC

CV7 closes and CC71 will close (CV7 closed limit swithch de-energizes the CC71 solenoid)

Term
SEC Mode Responses for the CCW System:
Definition

Mode I: Pps in auto and manual will be blocked until reset by SEC. What you have is what you get. After Reset, the third pp may come on as needed.

 

Mode II: All pps stopped and restarted in required sequence

 

Mode III: All pps stopped, SW122 closed and PPs do not restart.

 

Mode IV: Trip CCW Pp, affected SW122 closes and pps shift from auto to manual operation. Pps do not auto restart.