Term
2 countries where RGPs were popular |
|
Definition
|
|
Term
RGP flexure increases when... |
|
Definition
peripheral cornea is steep, high Dk |
|
|
Term
one complication if a px who has been wearing PMMA is refitted with Hydrogels |
|
Definition
Corneal Exhaustion syndrome |
|
|
Term
3 & 9 O clock staining seen in RGPs that are too flat/steep? |
|
Definition
|
|
Term
RGP classification: Group 1 - 4 |
|
Definition
1: MMA -Si - F 2: MMA +si - F 3: MMA + s + f 4: MMA - S + F |
|
|
Term
Advantages of Aspheric RGPs |
|
Definition
more tear exchange, less flare as no distinct zones, increased lens binding, mask up to 2Dc of corneal astig in asian, -3Dc in caucasians |
|
|
Term
0.1mm change in BC of RGP = ___ change in power |
|
Definition
|
|
Term
|
Definition
corneal astig >0.40mm (2Dc) |
|
|
Term
in RGP alignment fit, the tear lens should be ____D? |
|
Definition
|
|
Term
what % of water do RGP materials absorb? |
|
Definition
|
|
Term
|
Definition
|
|
Term
Silicone and fluorine in RGP polymer give what characteristics? |
|
Definition
Si: more oxygen permeability, poor wettability, protein deposits F: good oxygen permeability, wets well, deposit resistance |
|
|
Term
Problems with Silicone Acrylate GP lenses 3 |
|
Definition
protein deposits, 3&9 o clock staining, pappilary conjunctivitis |
|
|
Term
Fluorosilicone acrylates: problems |
|
Definition
lens binding, lipid deposits in some px |
|
|
Term
Fluorosilicone acrylates: advantages |
|
Definition
good oxygen permeability, good deposit resistance --> low CLPC, wettable |
|
|
Term
what material to use to solve 3-9oclock staining and CLPC? |
|
Definition
CAB cellulose acetate butylate |
|
|
Term
|
Definition
|
|
Term
why is edge clearance needed? 3 reasons |
|
Definition
tear exchange, more comfortable and less distortion, aid removal |
|
|
Term
Increasing diameter of RGP will |
|
Definition
increase comfort as edge slips under lid, but lens may extend beyond limbus in blinks |
|
|
Term
problems with high Dk lenses? 2 |
|
Definition
|
|
Term
7.85:7.80 / 8.65: 8.80 / 10.00:9.30 how many curve design is this lens? what does 7.85 refer to? what does 8.80 refer to? |
|
Definition
tricurve; BC 7.85; 8.80 is diameter of curve 1 |
|
|
Term
what manufacture method gives good blink induced movement? |
|
Definition
|
|
Term
Push up 0 - 100. which is tight? which is loose |
|
Definition
|
|
Term
3 method for measuring oxygen transmissibility of a lens. which is most accurate for high Dk lenses |
|
Definition
coulometric, polarographic; coulometric |
|
|
Term
3 in vivo methods of measuring wetting angle |
|
Definition
sessile drop, wilhermy plate, captive bubble. |
|
|
Term
FDA classification: Grp 1 -4 means Watercontent/ionic? |
|
Definition
1: non ionic, low water 2: non ionic, high water 3: ionic, low water 4: ionic, high water |
|
|
Term
Adv and disadv of ionic vs nonionic materials |
|
Definition
ionic: more wettable, more protein deposits |
|
|
Term
rank lens manufacture methods )spin cast, lathe cut, cast moulded) according to lens movement on eye - most movement to least: |
|
Definition
lathe cut > spin cast > cast moulded |
|
|