Term
Recirc
Describe recirculation flow. |
|
Definition
-57.6 Mlbm/hr. -42% driving. -58% driven. |
|
|
Term
Recirc
Describe the recirculation loops. |
|
Definition
-2 loops. -1 external pump. -5 risers. -10 jet pumps (2 per riser). |
|
|
Term
Recirc
Describe the recirc pump MGs and power supplies. |
|
Definition
-Buss 11 - 11 recirc pump. -Buss 12 - 12 recirc pump. -Mechanical stop at 20%. |
|
|
Term
Recirc
Describe the recirc pump limits. |
|
Definition
-Pump speed limited to 30% speed until: -Discharge valve full open. -FW flow > or equal to 20% (15 sec time delay). |
|
|
Term
Recirc
Describe the function of the restriction bushing. |
|
Definition
Limits shaft leakage to 70gpm even if both seals fail. |
|
|
Term
Recirc
Describe the motor alarms setpoints. |
|
Definition
-Drive motor: 230F. -Pump motor: 293F. |
|
|
Term
Recirc
Describe the seal flow and leak rate. |
|
Definition
-Lower seal gets 3gpm from CRD. -Upper seal controls leakage to 3/4 gpm. |
|
|
Term
Recirc
Describe the MG set cooling mechanism. |
|
Definition
Cooled by AC lube oil which is cooled by service water. |
|
|
Term
Recirc
Describe the pump cooling medium, rates, and alarms. |
|
Definition
-RBCCW. -Low cooling water 58gpm. -High RBCCW temp 120F. -High seal cavity temp 160F. |
|
|
Term
Recirc
Describe the AC lube oil pumps rated flow and power supplies. |
|
Definition
-MCC-132/122. -614gpm at 75psig. |
|
|
Term
Recirc
Describe the DC lube oil pump rated flow and power supply. |
|
Definition
-Powered by D-313. -10gpm at 25 psig. |
|
|
Term
Recirc
Describe the lube oil standby features and setpoints. |
|
Definition
-27psig: standby AC oil pump starts. -27psig for 6 seconds: MG drive motor trip and scoop tube lock. -20psig: DC oil pump stops, drive motor start permissive. -14.3 psig: DC oil pump starts. -10 psig: Low drive motor/generator bearing oil press alarm. |
|
|
Term
Recirc
Describe the temp alarms associate with the MG sets. |
|
Definition
-55F low oil temp. -190F high oil temp. -210F MG drive motor trip, scoop tube lock. |
|
|
Term
Recirc
Describe the recirc system suction valve interlocks and power supplies. |
|
Definition
-Must be open to start pump. -If <90% will trip drive breaker. -Powered by MCC-133B/143B. |
|
|
Term
Recirc
Describe the recirc system discharge valves interlocks and power supplies. |
|
Definition
-Must be closed to start pump. -Must be >20-25% open w/in 66 seconds of pump start or drive motor breaker trip. -Pump speed <30% if not full open. -MCC-133B/143B. |
|
|
Term
Recirc
Describe the recirc drive motor breaker trips. |
|
Definition
-Set at -47". -LPCI loop select logic. -Hi-Hi lube oil tem 210F. -Low lube oil pressure <27psig w/ 6 second time delay. -Suction valve <90%. -Discharge valve <20-25% at 66secs. -2R-to-1R auto transfer. -Recirc MG gen lockout. -Drive motor bus U/V. -Local switch to TRIP. -Control to STOP. |
|
|
Term
Recirc
Describe the MG set field breaker trips. |
|
Definition
-Recirc MG gen lockout. -Generator loss of field. -Low-low Rx water level -47" for 7.3secs. -High Rx press 1135psig. -Manual ATWS. |
|
|
Term
Recirc
Describe what will give a recirc runback. |
|
Definition
-Steam flow > 55.4%and both pumps running and feed or condensate pumps trip runback to 50% reset at 50.7% steam flow. -Manual pull to runback to 50%. -FW flow <20% for 15 sec to 30%. -Disch not full open to 30%. |
|
|
Term
Recirc
Describe the pump seal flow. |
|
Definition
|
|
Term
Recirc
Describe the recirc system design basis. |
|
Definition
-Maintain system pressure boundary and flowpath for LPCI. -Drive flow for circulation of Rx water. -Vary the recirc flow. -Flowpath for RHR shutdown cooling. |
|
|
Term
Recirc
Describe the jet pump height and reason. |
|
Definition
2/3 core height keeps fuel covered during LOCA. |
|
|
Term
Recirc
Describe recirc flow (driving/driven). |
|
Definition
-42% driving (pumps). -58% driven (jet pumps). |
|
|
Term
Recirc
Describe recirc pump hi vibration setpoint. |
|
Definition
3 mils after 5 sec time delay. |
|
|
Term
Recirc
Describe the low recirc cooling water flow setpoint. |
|
Definition
|
|
Term
Recirc
Describe the floating throttle function. |
|
Definition
Minimizes spray onto motor if seal failure occurs. |
|
|