Shared Flashcard Set

Details

Reactor Recirculation System (Recirc)
BWR Systems
25
Other
Not Applicable
05/28/2012

Additional Other Flashcards

 


 

Cards

Term
Recirc

Describe recirculation flow.
Definition
-57.6 Mlbm/hr.
-42% driving.
-58% driven.
Term
Recirc

Describe the recirculation loops.
Definition
-2 loops.
-1 external pump.
-5 risers.
-10 jet pumps (2 per riser).
Term
Recirc

Describe the recirc pump MGs and power supplies.
Definition
-Buss 11 - 11 recirc pump.
-Buss 12 - 12 recirc pump.
-Mechanical stop at 20%.
Term
Recirc

Describe the recirc pump limits.
Definition
-Pump speed limited to 30% speed until:
-Discharge valve full open.
-FW flow > or equal to 20% (15 sec time delay).
Term
Recirc

Describe the function of the restriction bushing.
Definition
Limits shaft leakage to 70gpm even if both seals fail.
Term
Recirc

Describe the motor alarms setpoints.
Definition
-Drive motor: 230F.
-Pump motor: 293F.
Term
Recirc

Describe the seal flow and leak rate.
Definition
-Lower seal gets 3gpm from CRD.
-Upper seal controls leakage to 3/4 gpm.
Term
Recirc

Describe the MG set cooling mechanism.
Definition
Cooled by AC lube oil which is cooled by service water.
Term
Recirc

Describe the pump cooling medium, rates, and alarms.
Definition
-RBCCW.
-Low cooling water 58gpm.
-High RBCCW temp 120F.
-High seal cavity temp 160F.
Term
Recirc

Describe the AC lube oil pumps rated flow and power supplies.
Definition
-MCC-132/122.
-614gpm at 75psig.
Term
Recirc

Describe the DC lube oil pump rated flow and power supply.
Definition
-Powered by D-313.
-10gpm at 25 psig.
Term
Recirc

Describe the lube oil standby features and setpoints.
Definition
-27psig: standby AC oil pump starts.
-27psig for 6 seconds: MG drive motor trip and scoop tube lock.
-20psig: DC oil pump stops, drive motor start permissive.
-14.3 psig: DC oil pump starts.
-10 psig: Low drive motor/generator bearing oil press alarm.
Term
Recirc

Describe the temp alarms associate with the MG sets.
Definition
-55F low oil temp.
-190F high oil temp.
-210F MG drive motor trip, scoop tube lock.
Term
Recirc

Describe the recirc system suction valve interlocks and power supplies.
Definition
-Must be open to start pump.
-If <90% will trip drive breaker.
-Powered by MCC-133B/143B.
Term
Recirc

Describe the recirc system discharge valves interlocks and power supplies.
Definition
-Must be closed to start pump.
-Must be >20-25% open w/in 66 seconds of pump start or drive motor breaker trip.
-Pump speed <30% if not full open.
-MCC-133B/143B.
Term
Recirc

Describe the recirc drive motor breaker trips.
Definition
-Set at -47".
-LPCI loop select logic.
-Hi-Hi lube oil tem 210F.
-Low lube oil pressure <27psig w/ 6 second time delay.
-Suction valve <90%.
-Discharge valve <20-25% at 66secs.
-2R-to-1R auto transfer.
-Recirc MG gen lockout.
-Drive motor bus U/V.
-Local switch to TRIP.
-Control to STOP.
Term
Recirc

Describe the MG set field breaker trips.
Definition
-Recirc MG gen lockout.
-Generator loss of field.
-Low-low Rx water level -47" for 7.3secs.
-High Rx press 1135psig.
-Manual ATWS.
Term
Recirc

Describe what will give a recirc runback.
Definition
-Steam flow > 55.4%and both pumps running and feed or condensate pumps trip runback to 50% reset at 50.7% steam flow.
-Manual pull to runback to 50%.
-FW flow <20% for 15 sec to 30%.
-Disch not full open to 30%.
Term
Recirc

Describe the pump seal flow.
Definition
3-5 gpm from CRD.
Term
Recirc

Describe the recirc system design basis.
Definition
-Maintain system pressure boundary and flowpath for LPCI.
-Drive flow for circulation of Rx water.
-Vary the recirc flow.
-Flowpath for RHR shutdown cooling.
Term
Recirc

Describe the jet pump height and reason.
Definition
2/3 core height keeps fuel covered during LOCA.
Term
Recirc

Describe recirc flow (driving/driven).
Definition
-42% driving (pumps).
-58% driven (jet pumps).
Term
Recirc

Describe recirc pump hi vibration setpoint.
Definition
3 mils after 5 sec time delay.
Term
Recirc

Describe the low recirc cooling water flow setpoint.
Definition
58gpm.
Term
Recirc

Describe the floating throttle function.
Definition
Minimizes spray onto motor if seal failure occurs.
Supporting users have an ad free experience!