Term
Cond Feed
Describe the signifigant levels in the hotwells. |
|
Definition
Actual -At +90" hi-hi alarm. -At +33" hi alarm. -Ref Zero at +26". -At +19" low alarm. -Actual bottom at 0". Indicated -0" is 26" actual. -At +6" reject opens. -At +3" make up opens. -Has -15" to +15" range. Recorder alarms -At +7" high alarm. -At -7" low alarm. |
|
|
Term
Cond Feed
Describe the power supply to cond and feed pumps. |
|
Definition
-11 cond pump bus 13. -12 cond pump bus 14. -11 RFP 11 bus. -12 RFP 12 bus. -Both have breaker control power of D111/D211. |
|
|
Term
Cond Feed
Describe minimum flow requirements. |
|
Definition
-Per pump. -Cond pumps: 2500gpm. -SJAE intercondensor: 3000gpm. -RFP: 3300gpm. |
|
|
Term
Cond Feed
Describe where cond pumps discharge to. |
|
Definition
-Air ejector intercondensors (also to recombiners). -Steam packing exhauster. -Cond demin system to feed water heaters to RFP. |
|
|
Term
Cond Feed
Describe the temperature of feed water to Rx. |
|
Definition
Heated up by heaters to roughly 380F. |
|
|
Term
Cond Feed
Describe where cond pump min flow returns to. |
|
Definition
Recirc flow goes to HP condenser above the tubes. |
|
|
Term
Cond Feed
Describe cond pump starting limits. |
|
Definition
-2 starts allowed from ambient temp. -1 start allowed from op temp. -Motor assumed to have returned to normal temp after 60 minutes for idle or 30 minutes running. |
|
|
Term
Cond Feed
Describe cond pump low flow protection. |
|
Definition
Shuts recirc and reject when header pressure is less than 230psig. |
|
|
Term
Cond Feed
Describe cond pump recirc valve failure. |
|
Definition
Fail close on loss of air/power. |
|
|
Term
Cond Feed
Describe what supplies hood spray. |
|
Definition
|
|
Term
Cond Feed
Describe the RFP starting/trips requirements and which are interlocks. |
|
Definition
-11 pump trips on 70psig suction pressure for 10 sec. -12 pump trips on 70psig suction pressure for 15 sec. -Feed pumps trip at +48" Rx level. -Motor fault. -11 pump trips on 1200gpm low flow for 10 sec. -12 pump trips on 1200gpm low flow for 15 sec. -4 psig lube oil pressure (interlock). -Feedwater shutoff valves in drywell open (interlock). |
|
|
Term
Cond Feed
Describe where RFP min flow returns. |
|
Definition
|
|
Term
Cond Feed
Describe RFP recirc flow valve failure. |
|
Definition
-Loss of Y-90 casue valves to close. -Loss of Y-20 will not change position. -Loss of air causes valves to fail open. |
|
|
Term
Cond Feed
Describe RFP Aux oil pump. |
|
Definition
-Used during s/u and s/d. -Auto starts when shaft driven oil pump pressure is < or equal to 6psig or flow less or equal to 6 gpm. -Must be manually secured. |
|
|
Term
Cond Feed
Describe what cools the RFP oil cooler. |
|
Definition
|
|
Term
Cond Feed
Describe the feedwater heaters. |
|
Definition
-2 strings. -5 one half capacity heaters arranged with 3 low pressure heaters upstream of RFPs. -Raise temp 280F above hotwell temp. -Water passes through tubes and heated by turbine extraction steam. -Cascaded to next lower pressure heater. -Low pressure heaters drain to high pressure condenser. -Dump valves and drain valves provided to maintain levels in each heater. |
|
|
Term
Cond Feed
Describe dump and drain valve failure. |
|
Definition
-Dump valves fail open on loss of air. -Drain valves fail closed on loss of air. |
|
|
Term
Cond Feed
Describe the spill valves. |
|
Definition
-Spill valves on extraction lines interlocked to OPEN on turbine trip, high heater level, or inlet/outlet block valve closed. -Fail open on loss of air/power. |
|
|
Term
Cond Feed
Describe where steam packing exhauster drains and exhausts. |
|
Definition
-Non condensables to 1 3/4 minute hold up line. -Condensater to turbine building equipment drain sump. |
|
|