Term
Rad Waste

Describe the containment isolation valves and what happens on signal.
Definition
-The drywell equipment drain sum and drywell floor drain sump pump suction valves are containment isolation valves.
-Shut on group II.
-This will also trip the pumps.
Term
Rad Waste

Describe the pumps with essential power supplies.
Definition
-Rx building floor drain sump pumps: MCC-133/143.
-RHR room ECCS pumps: MCC-133/143.
Term
Rad Waste

Describe the drywell equipment drain sump recirc.
Definition
-If temp gets to 140F pump starts and recircs through a heat exchanger.
-HX cooled by RBCCW.
Term
Rad Waste

Describe the drywell floor drain sump and equipment drain sump level alarms.
Definition
2'6".
Term
Rad Waste

Describe where the condensate drip tank discharges to.
Definition
-Goes to the condenser if < or equal to 1umho conductivity and discharge pressure >10#.
-If not it goes to rad waste.
Term
Rad Waste

Describe the ECCS area sump pumps alarm and starts.
Definition
-Alarm at 4".
-2 pumps start at 6" and stops at 4".
-Other 2 pumps start at 8" and stops at 4".