device that receives energy of the x-ray beam, forms image of body part |
|
Definition
|
|
Term
T/F: In fluoro, the radiation is always coming from the bottom. |
|
Definition
|
|
Term
a film or other base material containing a processed imaged of an anatomic part of a patient as produced by action of x-rays on an IR |
|
Definition
|
|
Term
T/F: Contrast is the degree of black you can see. |
|
Definition
False: Optical density is the degree of black you can see. |
|
|
Term
__________ controls the energy and penetrating ability of the x-ray beam. |
|
Definition
Kilovoltage (kVp) (kVp) = strength |
|
|
Term
__________ is a measure of the x-ray tube current. |
|
Definition
|
|
Term
Exposure time (s) is expressed in __________. |
|
Definition
|
|
Term
mAs is a result of __________ multiplied by __________. |
|
Definition
milliamperage, seconds (mAs) = amount |
|
|
Term
T/F: All patients must be assumed to have communicable diseases. |
|
Definition
|
|
Term
Wash your hands __________ and __________ each patient! |
|
Definition
|
|
Term
Treat all bodily fluids as if they were __________. |
|
Definition
|
|
Term
What is the number 1 rule for markers? |
|
Definition
Always mark the correct side of the body |
|
|
Term
the central or principal beam of rays |
|
Definition
|
|
Term
The central ray (CR) should always be centered to the __________ _________. |
|
Definition
|
|
Term
The general goal of central rays is to place the CR at __________ angles to the structure being examined. |
|
Definition
|
|
Term
the distance from the anode or source of x-rays to the image receptor (IR) |
|
Definition
Source-to-Image Receptor Distance (SID) |
|
|
Term
T/F: The greater the source-to-image receptor distance (SID), the greater the body part is magnified. |
|
Definition
False: The greater the SID, the LESS the body part is magnified. |
|
|
Term
Source to Skin distance (SSD) should not be less than _____" and NEVER less than _____". |
|
Definition
|
|
Term
The 2 standard SIDs are _____" and _____". |
|
Definition
|
|
Term
__________ restricts the area of the x-ray beam. |
|
Definition
|
|
Term
T/F: Collimation minimizes the amount of radiation to the patient by reducing scatter. |
|
Definition
|
|
Term
T/F: Collimation reduces detail and contrast. |
|
Definition
False: Collimation IMPROVES detail and contrast. |
|
|
Term
Types of Image REceptor -IR |
|
Definition
Cassette with film Image Place (Computed Radiography) Solid-State Detectors- Direct Digital Radiography (DR) Portable digital radiography Flouroscopic screen |
|
|
Term
|
Definition
|
|
Term
|
Definition
wipes clean able to reuse |
|
|
Term
Solid State Detectors (DR) |
|
Definition
not physical cassette, automatically sends to computer |
|
|
Term
|
Definition
image is transmitted wirelessly onto portable |
|
|
Term
|
Definition
live xray - example upper GI |
|
|
Term
|
Definition
aka SI- one part imaged on top of another |
|
|
Term
|
Definition
each anatomic structure is compared to adjacent structure to ensure that structure is present and properly shown |
|
|
Term
|
Definition
the difference in density |
|
|
Term
|
Definition
the ability to visualize small structures |
|
|
Term
|
Definition
all radiographs have some degree of magnification because all body parts are 3 dimensional |
|
|
Term
|
Definition
body part is analyzed to insure every is aligned, and anatomical |
|
|
Term
__ is a Minor surgical procedure that doesn't require a rigid sterile technique |
|
Definition
|
|
Term
Two types of muslce contractions |
|
Definition
Voluntary and involuntary |
|
|
Term
Identification on Radiographs |
|
Definition
Pt name and Id # Date R and L marker Institution Name |
|
|
Term
#1 rule for all markers is too________ |
|
Definition
Always mark the correct side of body |
|
|
Term
3 general types of position used with Image Receptor Placement |
|
Definition
Diagonal Longitudinal Transverse |
|
|
Term
The CR is always _____ to IR |
|
Definition
|
|
Term
Goal of CR placement is at a ____angle |
|
Definition
|
|
Term
The _____the SID the _______ the body part is magnified |
|
Definition
|
|
Term
T?F Many experts regard collmination as the most important aspect of producing and optimal image |
|
Definition
|
|
Term
Gonadal Sheilding guidelines |
|
Definition
Always use in less patient refuses or clinical objective of exam is not compromised |
|
|
Term
You will decrease exposure technique with the following |
|
Definition
old age pneumothorax atrophy |
|
|
Term
You will increase exposure technique with the following |
|
Definition
pneumonia enlarged heart Ascities |
|
|
Term
DR technique is more sensitive to scattering t/f |
|
Definition
|
|
Term
DR technique collmination is very important t/f |
|
Definition
|
|
Term
In DR technique side not being used should be covered T/F |
|
Definition
|
|
Term
In DR technique the kV is not as critical T/F |
|
Definition
|
|
Term
|
Definition
Automatic Exposure Control |
|
|
Term
AEC -detectors that are chosen for a specific body part will terminate the exposure when reach sufficient amount of radiation |
|
Definition
|
|
Term
|
Definition
Kvp and mAs are selected by radiographer and detectors are not used |
|
|
Term
T/F Obese patients will IR size will look smaller on a obese pt. |
|
Definition
T- decreased source SSD ( source skin distance) |
|
|
Term
Exposure factors when imaging with obese pt |
|
Definition
need to increase exposure focal spot bucky and grid to reduce scatter |
|
|
Term
Imaging challenges with obese pt |
|
Definition
finding landmarks IR sizes Orientation Collmination |
|
|
Term
|
Definition
|
|
Term
|
Definition
|
|