Shared Flashcard Set

Details

Primary Containment (Pri Con)
BWR Systems
7
Other
Not Applicable
06/11/2012

Additional Other Flashcards

 


 

Cards

Term
Pri Con

Describe the designed pressures, temperatures, and leakage.
Definition
-Internal pressure of 56psig.
-External pressure of 2 psig.
-Temperature of 281 d-F.
-Leakage of 1.2% by weight & .5% by volume in 24 hours.
Term
Pri Con

Discuss atmoshpere inerting.
Definition
During power operation the drywell and TORUS inerted to <4% oxygen using nitrogen gas.
Term
Pri Con

Describe the torus-to-drywell vacuum breakers.
Definition
-8, 18" check valves.
-Air operation for testing.
-Full open at .5psid.
Term
Pri Con

Describe the torus water temp limits.
Definition
-Normal limit is < or equal to 90F and > or equal to 65F.
-Allowed up to 99F for testing but cannot be > 90F >24 hours after testing.
->120F must depress <200psig w/in 12 hours.
Term
Pri Con

Describe SPOTMOS.
Definition
-2 divisions.
-8 RTDs.
-Powered by Y-70 and Y-80.
Term
Pri Con

Describe drywell atmospheric cooling.
Definition
-4 fans in drywell with 16 dampers.
-Cooled by RBCCW.
-Maintain <135F for normal equipment ops.
-Designed to lower air temp <105F w/in 8-10 minutes post shutdown.
Term
Pri Con

Describe the TORUS size basis.
Definition
-Designed to absorb energy from DBA-LOCA without exceeding 170F.
-Assumes minimum level and max temp of 125F.
Supporting users have an ad free experience!