Term
OGS
Describe the function of OGS. |
|
Definition
-Allow for decay of radionuclides (Xenon/Krypton) prior to release. -Remove particulates and iodine from off gas stream. -Long term hold up for unusually high rad levels or event. -Controlled release of decayed off-gas. |
|
|
Term
OGS
Describe the compressor cycling pressures and alarms. |
|
Definition
-Loads at 5"Hg vac. -Unloads at 10.2" Hg vac. -High vac alarm at 2" Hg vac. -Low vac alarm at 13.2" Hg vac. -Controls 42"(30min) hold up line pressure (10.4 - 12.5 psia). |
|
|
Term
OGS
Describe the compressor suction filter purpose and alarms. |
|
Definition
-Remove particulate and iodine. -10" H2O. |
|
|
Term
OGS
Describe the compressor low oil pressure trip setpoint. |
|
Definition
-18psig. -Bypassed for 15secs on s/u. |
|
|
Term
OGS
Describe the compressor temp alarms/trips. |
|
Definition
-Discharge temp of 150F causes alarm. -2nd stage discharge temp of 375F causes alarm and compressor trip. |
|
|
Term
OGS
Describe compressor sealing air. |
|
Definition
-Normally supplied by plant air system. -Backed up by sealing air compressors. |
|
|
Term
OGS
Describe sealing air compressor low pressure alarm setpoint. |
|
Definition
|
|
Term
OGS
Describe the sealing air compressor inner high pressure setpoint. |
|
Definition
|
|
Term
OGS
Describe the full tank alarms and interlocks. |
|
Definition
-280psig get alarm on C-07. -285psig get alarm on C-252 and compressor trips. -310psig get alarm on C-252 and white light on C-07. |
|
|
Term
OGS
Describe tank storage requirements and timers. |
|
Definition
-Normally fill for 12 hours. -Placed in store cannot discharge for time of timer (set at 12 hours). -Normally let sit for 36 hours and set discharge rate at 12 hours. |
|
|
Term
OGS
Describe function of radioactive liquid drainage system. |
|
Definition
Collects, stores and transfers for disposal the liquid leakage and moisture condensation from components in OG system. |
|
|
Term
OGS
Describe the compressor power supplies. |
|
Definition
|
|
Term
OGS
Describe OG storage tank interlocks. |
|
Definition
-Prevent simultaneous opening of both fill and discharge valves on same tank. -Prevent opening of discharge on tank until 12 timer is up. |
|
|
Term
OGS
Describe the compressor trips. |
|
Definition
-2nd stage temp at 375F. -Compressor oil pressure < 18psig. -Motor overload. -Hydrogen analyzer INOP or >4% H2 with desuperheater condenser outlet (AO-7557A/B) open. |
|
|
Term
OGS
Describe the chiller trips. |
|
Definition
-Freon compressor suction < 10psig or discharge > 250psig. -Oil pressure < 11psig. -Chilled water < 35F. -Motor overload. |
|
|
Term
OGS
Describe the aux compressor trips. |
|
Definition
-Sealing air compressor discharge temp > 115F. -Motor overload. |
|
|
Term
OGS
Describe teh off gas discharge solenoid valve trips. |
|
Definition
Off gas temp discharge station < 32F. |
|
|