Term
|
Definition
accordion load, flat load, horshoe load oakland uses a flat load. |
|
|
Term
|
Definition
used for attack lines attached to a pump discharge. these are out cross lays. |
|
|
Term
|
Definition
for supply or attack line line often ends with apaters, hose strap, hydret wrench and spanner attached |
|
|
Term
upon reaching the fire area how many feet of working line should be available? |
|
Definition
|
|
Term
50 ft of hose line OUTSIDE of a builing will reach ___A.____ floors, and ____B.___ floor when taken inside via stairwell. |
|
Definition
|
|
Term
Crew members on a hoseline go in this order? |
|
Definition
1)nozzleperson on nozzle 2)officer a few feet behind 3)second FF halfway to coupling 4)engineer at the engine. |
|
|
Term
When advancing an uncharged hose over a ladder how far apart should the FF be? |
|
Definition
|
|
Term
what are two tools that are used to shut off the h2o when you need to extend a hoseline? |
|
Definition
hose clamps, break apart nozzle |
|
|
Term
Name three types of hose lays? |
|
Definition
forward lay, reverse lay, split lay |
|
|
Term
why might crews employ a split lay? |
|
Definition
the fire and water are in two different directions, such as on two different streets, thus needing to split the lay between two engines |
|
|
Term
This hose appliance connects two or more hoselines into one line with either a clapper or gate valve if only one line is connected? |
|
Definition
|
|
Term
This hose appliance divides one hoseline into two or more? |
|
Definition
A Wye (wye lines may be same size or smaller) |
|
|
Term
What denotes and Inservice roll vs. and out of service roll |
|
Definition
a roll that is in service will have th male coupling at the center of the roll. |
|
|
Term
what is the forward lay, and why is it the preffered method? |
|
Definition
engine stops first at water source to drop off supply line and then advances to fire location. preferred b/c attack engibe is close to fire for additional hoselines/ euiptment, and only one engine is need for water supply. |
|
|
Term
|
Definition
supply line is dropped off at fire location and the engine laying hose towards the water source |
|
|
Term
When laying a line up a stair well how should hose be flaked? |
|
Definition
up the outside of the stair well and around the outer corners of each bend . nozzle at fire door, first 50' flaked out on stairway above fire floor with 1st coupling on ssame landing as nozzle. |
|
|
Term
If you are lead off, what do you do after you have hooked up the hydrant? |
|
Definition
find the engineer, help flake out preconnected line, bring 1st coupling to nozzle, and bring some tools and back up nozzleperson. |
|
|
Term
|
Definition
remove air from hose/nozzle check for adequate operating pressure |
|
|
Term
what is the minimum flow pressure in the OFD for interior attack? |
|
Definition
|
|
Term
what is the purpose of ears? |
|
Definition
to assist with hose deployment. the first loop should give you 50 feet of hose and a nozzle |
|
|
Term
what is the difference between a back uop line and a second line? |
|
Definition
back up line is used to protect crews in the fire, if all is well this line will be charged but not flowing. a second line is actively flowing water to suppress the fire |
|
|
Term
what GPM does the akron assault 4714 nozzle deliver? what about the 4824? |
|
Definition
4714=150 gpm @ 50 psi
4824= 250 gpm @50 psi |
|
|
Term
how do we remove/prevent kinks? |
|
Definition
flaking out the hose properly prior to calling for water- feeding hoseline at corners "boxing out the corners", checking for kinks as you follow a hoseline into a structure |
|
|
Term
when would we use a 2 1/2" or greater hoseline? |
|
Definition
A dvanced fire D efensive operarions U nable to locate L arge compartment T tons of water needed s standpipe operations |
|
|
Term
when do we use the high rise/ hotel packs? |
|
Definition
|
|
Term
what is the realtionship between hose diameter and friction loss? |
|
Definition
the greater the diameter the less friction loss. |
|
|
Term
what is the purpose of the four way? |
|
Definition
to convert hydrant pressure to engine pressure or "to increase the water pressure without interrupting the water supply" |
|
|
Term
name the 4-ways in the OFD? |
|
Definition
blake, legere, akron and hummet. acronym BLAH |
|
|
Term
what are the advantages of low pressure nozzles? |
|
Definition
less nozzle reaction, reduced engine and nozzle pressures cause hose to be less stiff/ easier to maneuver, droplets tend to be larger than those on the existing smooth bore nozzle. |
|
|
Term
what do you wnat with you at the fire door? |
|
Definition
nozzle and the first coupling |
|
|
Term
what can the lead off person do to assist the nozzle? |
|
Definition
clear the hose bed, bring the irons, and flake out hose/ bring more hose. |
|
|
Term
|
Definition
the first person who goes through it |
|
|
Term
how do you hoist a hose with rope? |
|
Definition
i person attaches rope on fire floor, throws rope bag down to peron with nozzle. nozzle is the hoisted up to firefloor with hose, hose is secured with larks foot/ clove hitch |
|
|
Term
what knot do you use when hoisting the nozzle with rope? |
|
Definition
figure eight on a bight, throgh the handle and around the nozzle |
|
|
Term
when will the lead off person typically need assistance? |
|
Definition
if the hydrant has a locking cap. |
|
|
Term
what can the nozzle person easily do to assist the lead off person? |
|
Definition
|
|
Term
|
Definition
a short fold of hose or a reverse fold used when the coupling ends up where a fold should be, or when the coupling is too far forward. |
|
|
Term
moving a line of hose forward is called? |
|
Definition
|
|
Term
what are the steps the lead off person will take? |
|
Definition
don SCBA-step down check for traffic-grab 4-way, tools, hose strap-wrap hydrant, yell "lay line" while behind hose-remove hose strap, open hydrant cap, connect 4 way, flake out hose,-"water!" charge line - grab tools check for kinks |
|
|
Term
when an officer tells you to proceed to a given location what should you do? |
|
Definition
repeat the order back to the officer and tell your back up person, proceed with a purpose. |
|
|
Term
what are the two types of nozzle theory? |
|
Definition
direct attack method/ indirect method (cheif layman theory) |
|
|
Term
what conditions must be in place for the indirect attack method to work? |
|
Definition
building must be reasonably enclosed, fire must already have generated a great amount of heat prior to attack. |
|
|
Term
what is the indirect method nozzle theory? |
|
Definition
inject fog into hottest part of fire, the overhead, and allow time for creation of steam to extinguish fire. |
|
|
Term
where is water applied in the direct attack method? |
|
Definition
at the base of the material at the flame feul interface? |
|
|
Term
would the indirect methos work on a building that was already vented? |
|
Definition
|
|
Term
what are the two most important factors affecting fire extinguishment? |
|
Definition
rate of flow and water distribution. |
|
|