Term
| ANY FIRE EQUIPMENT DEALER, LICENSED PURSUANT TO SECTION 633.304, WHO DOES NOT WANT TO ENGAGE IN SERVICING, INSPECTING, RECHARGING, REPAIRING OR INSTALLING HALON EQUIPMENT MUST FILE WHAT? |
|
Definition
| MUST FILE AN AFFIDAVIT ON FORM DFS-K3-1482 "FIRE EQUIPMENT DEALER HALON EXEMPTION AFFIDAVIT" |
|
|
Term
| WHAT IS THE MINIMUM EQUIPMENT AND FACILITIES REQUIRED PER CLASS OF LICENSE FOR A LICENSE? |
|
Definition
| HYDROSTATIC TEST EQUIPMENT FOR HIGH PRESSURE TESTING AND CALIBRATED CYLINDER |
|
|
Term
| WHAT MAINTENANCE AND REQUIREMENTS ARE REQUIRED FOR THE MINIMUM EQUIPMENT AND FACILITIES REQUIRED FOR "A" LICENSE? |
|
Definition
MAINTAINED IN COMPLIANCE WITH THE REQUIREMENTS OF COMPRESSED GAS ASSOCIATION INC, PUBLICATION CGA C-1, THE EDITION AS ADOPTED IN RULE CHAPTER 69A-3
AND
FAC DOT CERTIFICATION LETTER POSTED ON OR NEAR THE TEST APPARATUS IDENTIFYING A CURRENT RETESTER IDENTIFICATION NUMBER ISSUED TO FACILITY |
|
|
Term
| WHAT MINIMUM EQUIPMENT AND FACILITIES ARE REQUIRED FOR "D" LICENSE? |
|
Definition
- CABLE CRIMPING TOOL fOR PRE ENGINEERED SYSTEMS
- COCKING LEVER FOR PRE ENGINEERED SYSTEMS
- PIPE VISE, DIES, REAMER, ETC
|
|
|
Term
| WHAT MINIMUM EQUIPMENT IS NEEDED FOR LICENSE CLASS "A, B, C"? |
|
Definition
| STOCK OF SUPPLIES FOR EXTINGUISHERS AND OR PREENGINEERED SYSTEMS BEING INSTALLED AND SERVICES IN ACCORDANCE WITH THE MANUFACTURERS SPECIFICATION |
|
|
Term
| HOW MANY DAYS DO YOU HAVE TO REFLECT CHANGES TO LICENSE AND PERMIT WHEN THERE IS A CHANGE OF RESIDENCE, PRINCIPAL BUSINESS LOCATION, OR NAME? |
|
Definition
|
|
Term
| WHAT MUST PERMITTEES HAVE ON THEM AT ALL TIMES WHILE ENGAGING IN THE SERVICING, RECHARGING, REPAIRING, TESTING, INSPECTION, OR INSTALLING OF FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS? |
|
Definition
| PERMITTEES MUST HAVE A VALID AND SUBSISTING PERMIT |
|
|
Term
| WHAT SERVICES MAY BE PERFORMED BY A PERMITTEE? |
|
Definition
| A PERMITEE MAY PERFORM ONLY THOSE SERVICES AUTHORIZED UNDER THE LICENSEE EMPLOYING SUCH PERMITEE. |
|
|
Term
| A PERMIT SHALL BE VALID SOLELY FOR USE BY WHO? |
|
Definition
| FOR USE BY THE HOLDER THEREOF IN HIS OR HER EMPLOYMENT BY THE LICENSEE UNDER WHOSE LICENSE THE PERMIT WAS ISSUED. |
|
|
Term
| WHAT IS THE CHARGE FOR THE COURSE FOR PORTABLE FIRE EXTINGUISHER LICENSES AND PERMITS. |
|
Definition
| THE CHARGE FOR THE COURSE IS $150.00 |
|
|
Term
| EACH APPLICANT MUST RECEIVE AND AVERAGE SCORE OF ____% ON DAILY EXAMINATIONS TO BE QUALIFIED TO SIT FOR THE CERTIFICATION EXAMINATION FOR PORTABLE FIRE EXTINGUISHER LICENSES AND PERMITS. |
|
Definition
|
|
Term
| HOW MANY HOURS IS THE CERTIFICATION COURSE OF INSTRUCTION AT THE FLORIDA STATE FIRE COLLEGE? |
|
Definition
| 40 HOUR CERTIFICATION COURSE |
|
|
Term
| WHAT IS THE PASSING SCORE FOR THE STATE CERTIFICATION EXAM? |
|
Definition
|
|
Term
| IF ANYONE FAILS TO COMPLETE A CERTIFICATION COURSE SHALL BE RESCHEDULED AT NO FEWER THAN? |
|
Definition
| NO FEWER THAN 30 DAY INTERVALS |
|
|
Term
| ANYONE FAILING THE EXAM WILL BE PERMITTED TO TAKE THE EXAM AT NO FEWER THAN, HOW MANY DAYS? |
|
Definition
|
|
Term
| ALL LICENSED FIRE EQUIPMENT DEALERS ARE REQUIRED TO COMPLETE WHAT HOURS AND WHAT SUBJECT FOR REQUIRED CONTINUING EDUCATION FOR LICENSE RENEWAL? |
|
Definition
- 1 HOUR OF BUSINESS PRACTICES CLASSES
- 1 HOUR OF WORKERS COMPENSATION CLASS
- 14 HOURS OF TECHNICAL CONTENT
|
|
|
Term
| HOW LONG DO LICENSED FIRE EQUIPMENT DEALERS HAVE TO COMPLETE THE CONTINUING EDUCATION CLASSES? |
|
Definition
|
|
Term
| WHAT IS THE EXCEPTION FOR CONTINUING EDUCATION COURSE REQUIREMENTS FOR A LICENSEE WHO RECEIVES AN INITIAL LICENSE ISSUED FOR 1 YEAR OR LESS? |
|
Definition
| SHALL BE REQUIRED TO COMPLETE 50% OF THE REQUIRED HOURS FOR A BIENNIAL LICENSE. |
|
|
Term
| WHAT IS THE EXCEPTION FOR CONTINUING EDUCATION COURSE REQUIREMENTS FOR A LICENSEE WHO RECEIVES AN INITIAL LICENSE ISSUED FOR 1 YEAR OR LESS? |
|
Definition
| SHALL BE REQUIRED TO COMPLETE 50% OF THE REQUIRED HOURS FOR A BIENNIAL LICENSE. |
|
|
Term
| ALL CURRENT LICENSE HOLDERS AND PERMIT HOLDERS, REGARDLESS OF ANY PREVIOUS CONTINUING EDUCATION DUE DATE, MUST PROVIDE PROOF OF WHAT EDUCATION? |
|
Definition
| MUST PROVIDE PROOF OF SIXTEEN HOURS OF CONTINUING EDUCATION FOR RENEWAL ON DECEMBER 31, 2011 AND EVERY TWO YEAR PERIOD THEREAFTER. |
|
|
Term
| WITH IN HOW MANY DAYS OF CONCLUSION OF EACH APPROVED CONTINUING EDUCATION COURSE THE ORGANIZATIONS SHALL INFORM THE REGULATORY LICENSE SECTIONS |
|
Definition
|
|
Term
| WHAT MATERIAL SHALL A 6 YEAR MAINTENANCE TAG DECAL BE? |
|
Definition
| THE DECAL SHALL EITHER BE METALLIZED OR OF AN EQUALLY DURABLE MATERIAL. |
|
|
Term
| THE RECORD TAG FOR 6 YEAR MAINTENANCE SHALL CONTAIN WHAT INFORMATION? |
|
Definition
- YEAR AND MONTH THAT THE 6 YEAR MAINTENANCE WAS PERFORMED AND THE NAME OF THE AGENCY PERFORMING THE MAITENANCE
|
|
|
Term
| WHAT SHALL BE REMOVED FROM AN EXTINGUISHER PRIOR TO A CURRENT TAG OR LABEL IS PLACED ON THE EXTINGUISHER? |
|
Definition
| ALL TAGS, LABELS AND DECALS REQUIRED BY THE STATE FIRE MARSHAL WHICH ARE OUT OF DATE. |
|
|
Term
| APPROVED STANDARD SERVICE TAGS, PRESSURE SENSITIVE LABELS OR DECALS SHALL BEAR WHAT INFORMATION? |
|
Definition
- "DO NOT REMOVE"
- SERIAL NUMBER OF EXTINGUISHER
- NAME OF PERSON WHO PERFORMED THE SERVICE ON THE EXTINGUISHER
- PERMIT NUMBER OF THE PERSON WHO SERVICED THE EXTINGUISHER
- INDICATE THE TYPE OF SERVICE PERFORMED
- INDICATE THE TYPE OF EXTINGUISHER INVOLVED
- INDICATE THE MONTH AND THE YEAR THAT THE SERVICE WAS PERFORMED BY MEANS OF PERFORATION SO THAT ONLY THE SPECIFIC MONTH IS INDICATED
|
|
|
Term
| THE SIZE OF THE STANDARD SERVICE TAGS, PRESSURE SENSITIVE LABELS OR DECALS SHALL BE A MINIMUM SIZE OF NO LESS THAN WHAT? |
|
Definition
| NO LESS THAN 2 1/2" AND NO GREATER THAN 3" BY NO LESS THAN 5 1/4" AND GREATER THAN 5 3/4" |
|
|
Term
| WHAT SHALL BE PROVIDED FOR AN EXTINGUISHER EACH TIME AN EXTINGUISHER IS OPENED FOR ANY TYPE OF INTERNAL SERVICE OR FOR ANY OTHER PURPOSE? |
|
Definition
| A NEW VERIFICATION SERVICE COLLAR |
|
|
Term
| WHEN AND AFTER WHAT SHALL TAMPER INDICATORS OR SEALS BE REPLACED? |
|
Definition
| EACH YEAR AND AFTER EACH RECHARGE OF A PORTABLE FIRE EXTINGUISHER |
|
|
Term
|
Definition
| STANDARD ON CARBON DIOXIDE EXTINGUISHING SYSTEMS |
|
|
Term
| WHAT IS NFPA 12 A STANDARD ON? |
|
Definition
| STANDARD ON HALON 1302 FIRE EXTINGUISHING SYSTEMS |
|
|
Term
|
Definition
| DRY CHEMICAL EXTINGUISHING SYSTEMS |
|
|
Term
| NFPA 17A IS STANDARD FOR? |
|
Definition
| WET CHEMICAL EXTINGUISHING SYSTEMS |
|
|
Term
| NFPA 96 1998 EDITION IS STANDARD FOR? |
|
Definition
| STANDARD FOR VENTILATION CONTROL AND FIRE PROTECTION OF COMMERCIAL COOKING |
|
|
Term
| NFPA 2001 IS STANDARD FOR? |
|
Definition
| STANDARD ON CLEAN AGENT FIRE EXTINGUISHING SYSTEMS |
|
|
Term
|
Definition
| STANDARD FOR DIPPING AND COATING PROCESSES USING FLAMMABLE OR COMBUSTIBLE LIQUIDS |
|
|
Term
| WHEN A PRE ENGINEERED SYSTEM IS INSTALLED HOW MANY COPIES OF THE INSPECTION REPORT SHALL THERE BE AND WHO RECEIVES THE COPIES? |
|
Definition
- TWO COPIES
- ONE COPY SHALL BE SIGNED BY AND DELIVERED TO OWNER OR REPRESENTATIVE OF THE OWNER
- ONE COPY SHALL BE RETAINED IN THE FIRE EQUIPMENT DEALERS FILES
|
|
|
Term
| HOW LONG SHOULD THE FIRE EQUIPMENT DEALER RETAIN FILES AFTER A PRE ENGINEERED SYSTEM? |
|
Definition
| FOR A PERIOD OF NOT LESS THAN 3 YEARS AFTER THE LAST INSPECTION |
|
|
Term
| ALL PRE ENGINEERED SYSTEMS REQUIRE WHAT ITEMS ON THE INSPECTION REPORT CONCERNING THE LOCATION OF SYSTEM |
|
Definition
- LOCATION OF SYSTEM
- BUSINESS NAME OF FACILITY
- STREET ADDRESS INCLUDING CITY STATE AND ZIP
- PHONE NUMBER
- NAME OF OWNER OR MANAGER
|
|
|
Term
| WHAT 15 ITEMS ARE REQUIRED TO BE ON THE INSPECTION REPORT |
|
Definition
- LOCATION OF SYSTEM (BUSINESS LOCATION)
- WHETHER THE REPORT IS FOR ANNUAL, SEMI ANNUAL, RECHARGE, NEW INSTALLATION OR RENOVATION
- WHERE THE SYSTEM IS LOCATED IN THE FACILITY
- TYPE OF SYSTEM, MANUFACTURER, MODEL NUMBER, SIZE OF BOTTLES
- METHOD, STYLE AND DEGREE OF ACTUATION
- REFERENCE TO DRAWING NUMBER OR PAGE NUMBER AND DATE OF MANUFACTURERS MANUAL
- DATE OF LAST HYDROSTATIC TEST
- DATE OF LAST RECHARG
- SERIAL NUMBER
- WHETHER A FUEL SHUT OFF IS GAS OR ELECTRIC AND SIZE
- A DRAWING OF A NEW INSTALLATION, A FIRST INSPECTION, OR CHANGES
- RESPONSES TO 3 QUESTIONS REQUIRED BY NFPA
- COMMENTS SECTION
- STATEMENT OF THE PERMITTEE
- THE PERMITTEES NAME, SIGNATURE, PERMIT NUMBER, DATE AND TIME OF INSPECTION AND CUSTOMERS SIGNATURE
|
|
|
Term
| WHAT 5 ITEMS ARE REQUIRED IN THE INSPECTION REPORT FOR A NEW INSTALLATION, FIRST INSPECTION OR WHENEVER CHANGES ARE MADE? |
|
Definition
- SIZES OF HOOD, PLENUM, AND DUCTS
- SIZES, TYPES AND LOCATIONS OF COOKING APPLIANCES
- POSITIONS OF ALL NOZZLES, IDENTIFICATION OF NOZZLES, THEIR DISTANCES FROM THE HAZARDS THAT THEY PROTECT
- POSITIONS OF ALL DETECTORS
- DIAGRAM OF THE ENTIRE PIPING INSTALLATION
|
|
|
Term
| WHAT ARE THE 3 QUESTIONS REQUIRED IN AN INSPECTION REPORT? |
|
Definition
- WERE THE INSPECTION AND MAINTENANCE PERFORMED IN ACCORDANCE WITH THE PRESENTLY ADOPTED ADDITIONS OF NFPA?
- WAS THE SYSTEM TAGGED IN ACCORDANCE WITH RULE 69A-21.303 FAC?
- WERE THE INSPECTION AND MAINTENANCE PERFORMED IN ACCORDANCE WITH THE MANUFACTURERS MANUAL AND THE MANUFACTURERS SPECIFICATION?
|
|
|
Term
| WHAT IS THE STATEMENT REQUIRED IN THE INSPECTION REPORT? |
|
Definition
| A STATEMENT THAT THE PERMITTEE CERTIFIES THAT HE PERSONALLY INSPECTED THE SYSTEM AND FOUND THE CONDITIONS TO BE AS INDICATED ON THE REPORT. |
|
|
Term
| WHAT DOES "BOARD" MEAN ACCORDING TO NFPA 33? |
|
Definition
| THE FLORIDA FIRE SAFETY BOARD |
|
|
Term
| WHAT DOES THE NFPA 633 DEFINE AS A CONTRACTOR 1? |
|
Definition
| MEANS A CONTRACTOR WHOSE BUSINESS INCLUDES THE EXECUTION OF CONTRACTS REQUIRING THE ABILITY TO LAY OUT, FABRICATE, INSTALL, INSPECT, ALTER, REPAIR, AND SERVICE ALL TYPES OF FIRE PROTECTIONS SYSTEMS, EXCLUDING PRE ENGINEERED SYSTEMS |
|
|
Term
| FIRE EQUIPMENT DEALER CLASS "A" MEANS? |
|
Definition
A LICENSED FIRE EQUIPMENT DEALER WHOSE BUSINESS IS LIMITED TO SERVICING, RECHARGING, REPAIRING, INSTALLATION, OR INSPECTING ALL TYPES OF FIRE EXTINGUISHERS AND CONDUCTING HYDROSTATIC TESTS ON ALL TYPES OF FIRE EXTINGUISHERS
- HYDRO AND RECHARGE ALL EXTINGUISHERS INCLUDING CARBON DIOXIDE
|
|
|
Term
WHAT DOES FIRE EQUIPMENT DEALER CLASS "B" MEANS
|
|
Definition
A LICENSED FIRE EQUIPMENT DEALER WHOSE BUSINESS IS LIMITED TO SERVICING, RECHARGING, REPAIRING, INSTALLING, OR INSPECTION ALL TYPES OF FIRE EXTINGUISHERS, INCLUDING RECHARGING CARBON DIOXIDE UNITS AND CONDUCTING HYDROSTATIC TEST ON ALL TYPES OF FIRE EXTINGUISHERS EXCEPT CARBON DIOXIDE
- YES RECHARGE CARBON DIOXIDE
- NO HYDRO CARBON DIOXIDE
- YES EVERYTHING ELSE
|
|
|
Term
| WHAT DOES FIRE EQUIPMENT CLASS "C" MEAN? |
|
Definition
MEANS A LICENSED FIRE EQUIPMENT DEALER WHOSE BUSINESS IS LIMITED TO SERVICING RECHARGING REPAIRING INSTALLING OR INSPECTING ALL TYPES OF FIRE EXTINGUISHERS EXCEPT RECHARGING CARBON DIOXIDE UNITS AND CONDUCTING HYDROSTATIC TESTS ON ALL TYPES OF FIRE EXTINGUISHERS EXCEPT CARBON DIOXIDE
- NO RECHARGE CARBON DIOXIDE
- NO HYDRO CARBON DIOXIDE
- YES ALL OTHERS
|
|
|
Term
| FIRE EQUIPMENT DEALER CLASS D MEANS? |
|
Definition
| A LICENSED FIRE EQUIPMENT DEALER THAT SERVICES ALL TYPES OF PRE ENGINEERED FIRE SYSTEMS |
|
|
Term
| WHAT DO THE TERM "FIRE EXTINGUISHER" MEAN ACCORDING TO NFPA 633 |
|
Definition
- IS PORTABLE AND CAN BE CARRIED OR IS ON WHEELS
- IS MANUALLY OPERATED
- MAY USE A VARIETY OF EXTINGUISHING AGENTS THAT ARE UNDER PRESSURE
- IS RECHARGEABLE OR NON RECHARGEABLE
- IS INSTALLED, SERVICED, REPAIRED, RECHARGED, INSPECTED, AND HYDROTESTED
- IS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY
|
|
|
Term
| PRE ENGINEERED SYSTEM USES ____ VARIETY OF EXTINGUISHING AGENTS? |
|
Definition
|
|
Term
| IF THE STATE FIRE MARSHAL FINDS THAT 1 OR MORE GROUNDS EXIST FOR THE SUSPENSION, REVOCATION, OR REFUSAL TO ISSUE, RENEW, OR CONTINUE ANY LICENSE, CERTIFICATE, OR PERMIT ISSUED THE STATE FIRE MARSHALL MAY WHAT TWO ALTERNATIVES? |
|
Definition
- AN ADMINISTRATION FINE NOT TO EXCEED 1,000 FOR EACH VIOLATION NOT TO EXCEED 10,000
- PROBATION FOR A PERIOD NOT TO EXCEED 2 YEARS
|
|
|
Term
| HOW LONG DOES THE CERTIFICATE HOLDER OR PERMITTEE HAVE TO PAY THE STATE FIRE MARSHALL AND IMPOSED FINE? |
|
Definition
|
|