Term
Which of the following is NOT a concern related to activity and dimensional requirements of programming? A.Accessibility B. Color Preference C. # of Ocuupants D. Social Interation |
|
Definition
ANSWER B. COLOR PREFERENCE |
|
|
Term
The initial budget should be provided to the client during which of the following phases? A.Preliminary Design B. Initial Review C. Programming D. final Design |
|
Definition
ANSWER A PRELIMINARY DESIGN |
|
|
Term
The concept of open office planning originated in the early 1960s in what country? A. France B. Germany C.Italy D.US |
|
Definition
|
|
Term
Behavioural Mapping is best defined as... A.the method by which the designer programs his/her work B.the method of observing how the space is used C.the psychographics of the client D. the method of quantifying human behaviour |
|
Definition
ANSWER C psychographics of client |
|
|
Term
Overlapping circles representing Social Zone, Private Zone, and Service Zones are utilized during which phase of the project? A.Circulation Planning B.Programming C.Space Planning D.Construction Documentation |
|
Definition
|
|
Term
The primary activity centers of a basic kitchen are... A.Plumbing/Elec/Arch. Zones B.Receiving/Storage, Clean-Up, Food Prep, Cooking C.Sink, stove, refrig, counter D.straight line, gallery, L-shape, island |
|
Definition
ANSWER B RECEIVING/STORAGE, CLEAN-UP, FOOD PREP, COOKING |
|
|
Term
The program does not include: A. A statement of the design problem B. A list of the kinds of spaces & relationships C. Specific Needs for Equip, Storage & their relationships D. a list of recommended finishes & furnishings |
|
Definition
ANSWER D a list of recommended finishes & furnishings |
|
|
Term
Simple declarative sentances that concisely describe the ID's principle ideas behind a proposed design - funct.& aesthetic, are part of? A.Comparative Analysis B.Concept Statement C.Critical Review D.Scope of services |
|
Definition
ANSWER B CONCEPT STATEMENT |
|
|
Term
A Person will tolerate closer presence of a stranger...A.side-to-side B. Face-to-Face C. of the opposite sex D. of the same sex |
|
Definition
|
|
Term
A schematic or bubble diagram is...A. Always drawn to scale B.Shows the exact proportion & placement of walls & doors C.Roughly shows the relative size and adjacencies of each activity area D. the first step in the programming process |
|
Definition
|
|
Term
Ergonomics is concerned with... A. Designing to meet the needs of Body Mechanics B.the measurement of body dims C.the engineering aspect of furniture design D. the effect of spatial realities on social groups |
|
Definition
ANSWER A DESIGNING TO MEET THE NEEDS OF THE BODY |
|
|
Term
The most useful tool for analyzing interrelationships between required spatial areas is a... A. Hierarchical Organization Chart B.Functional Adjacency Diagram C.Programming Matrix D. User Needs Analysis |
|
Definition
ANSWER C PROGRAMMING MATRIX |
|
|
Term
To minimize chatting between visitors & receptionist in a small office reception area, the ideal separation between guest and receptionist's work area... A. 3' B. 4' C. 9' D. 24' |
|
Definition
ANSWER C 9' (outer social zone) |
|
|
Term
Ther person most qual. to develop an open office plan for a mid-size corp...A.office mngr w/intimate knowledge of office workings B. facilities mngr who knows existing equip. C.indep.prof.space planner w/out ties to corp. d. in house staff with knowled |
|
Definition
ANSWER C. independent design professional |
|
|
Term
Conclusions developed from a preliminary data collection must include diagrams of typical workplace layouts and...A. actual floor plan B. the scope & purpose of the proj. C.a listing of unnecessary equip. D. An estimate of workplace cost |
|
Definition
ANSWER B. - scope & purpose of proj. |
|
|
Term
A space planner may take advantage of the services of a manufacturer or office supply distributor, but only after... |
|
Definition
a specific system has been selected |
|
|
Term
Hard-line drawings and elevations alone may NOT be sufficient for contractors to estimate the cost of the project. They also need... A. AXO drawings B. Schedules C. Specifications D. Working Drawings |
|
Definition
|
|
Term
Producing hardline drawings for furniture arrangements, colour & material selection is accomplished in which stage of the design process? a. Preliminary Design B. Design Development C. Presentation D. Construction Drawings |
|
Definition
ANSWER B DESIGN DEVELOPMENT |
|
|
Term
Orthographic & Axonometric Projections have what characteristic in common? |
|
Definition
ANSWER - the projections are true dimensions of space |
|
|
Term
From a maintenance standpoint, a poor choice for a commercial bar top would be... A.Epoxy B. Marble C. Plastic Laminate D. Wood |
|
Definition
|
|
Term
In estimating drapery width, a 150% fullness is equal to ___ times the rod width. 1.5, 2, 2.5, 3 |
|
Definition
ANSWER 2.5 Drapery fullness is given as the amount in addition to the rod width - 100% fullness is actually twice the rod width, 225% is 3.25x rod width |
|
|
Term
What is typically installed over masonry walls, window sills, and lintels as a permanent moisture barrier? A.Caulking B. Galvanized Copper C. Flashing D. a reveal |
|
Definition
|
|
Term
To isolate a high noise area from a quiet area, the floor plans and ceiling in that area should A.free of rigid contact with building struc. B.have both aborptive & reflective surfaces C.have 12"STC battens D. be double laminated in a cross pattern |
|
Definition
ANSWER A free of rigid contact with structure |
|
|
Term
ID must support central HVAC requirements for air returns. This can be done by? |
|
Definition
Providing the doors with undercuts |
|
|
Term
Most indoor light for working/reading is waht percentage of the daylight (outdoor) level? |
|
Definition
|
|
Term
Sound travel through a medium (wall, air, ducts, pipes, etc.) occurs because of... |
|
Definition
|
|
Term
A primary consideration when determining the amount of wattage use for lighting is... A. the type of fixture spec'd B.amount of heat generated by the specific wattage C. the colour rendition achieved by various wattage levels D. the spacing of fixtu |
|
Definition
|
|
Term
The preferred location of luminaries to light an office desk are... A to the side or directly over the desk chair B. 2ft in front of desk C. 6ft on either side of desk D. 6ft on center throught clg |
|
Definition
ANSWER to the side or directly over the desk chair |
|
|
Term
The spacing of sprinkler heads in the clg is determined by what criteria? A. type of constr. B. relative fire hazard classification of bldg C. # of occupants of the bldg related to total sqft D. # and location of fire hydrants near bldg |
|
Definition
ANSWER B relative fire hazard |
|
|
Term
Manuf. Fibres can be divided into 2 categories. Which fibres are in the same category A.Rayon/Nylon/Saran B.Acetate/Acrylic/Olefin C.Polyester/Triacetate/Nylon D. Olefin/Acrylic/Vinyl |
|
Definition
ANSWER D. OLEFIN/ACRYLIC/VINYL |
|
|
Term
To reduce the abrasion of fabric when pulled tightly over corners of upholstery, do what... A.add tufting B.specify only nylon C. use a softer under cushion material D.underline thin upholstery material |
|
Definition
|
|
Term
Which wall finish is the most ecologically sustainable? A. wd panelling from timber harvested from agroforest B. Wd panelling from a readily available local species C. Type II cellulose wallcovering over gyp bd D.Local stone tile installed w/metal fa |
|
Definition
ANSWER D local stone tile with metal fasteners |
|
|
Term
What is the minimum anti-static guideline for carpet in an office where personal computers are used? |
|
Definition
ANSWER 3.0kv @ 20% RH & 70E F |
|
|
Term
The twerm "stick building" refers to what? |
|
Definition
ANSWER the construction of a building piece-by-piece on site |
|
|
Term
If every watt of electricity used in production of electrical light generate 3.4 BTUs of heat per hour, What is the resulting heat generating efficiency of lighting? |
|
Definition
|
|
Term
The costly mistake of adding receptacles after the walls have been finished could have been avoided if proper use had been made of the ___ phase of the design process. A.Bidding B.Scheduling C.Specifications D.Supervision |
|
Definition
|
|
Term
CHT/EXH/JB are abbreviations which can be found on the : A. elec plans b. RCP C. working dwgs D.Cabinetry Details |
|
Definition
ANSWER B.
CHT = ?, EXH = Exhaust, Jb = Junction Box |
|
|
Term
Which of the following budget methods would be most appropriate in determining costs for a hotel guest room tower in the programming phase? A. Sq.ftage B. Functional Unit C. Parameter D. Qty. Take-off |
|
Definition
ANSWER B. Functional unit |
|
|
Term
the space planning of a project involves, mech, acoust., and lighting consultants. Who is responsible for coordinating their work? A.professional space planner, B.Staff facilities Manager C.Office Manager D. Special Projects Person |
|
Definition
ANSWER B. Staff Facilities Manager |
|
|
Term
Once the decision has been made to employ a professional space planner, the success of the project is based upon the: A. Selection of company coordinator B. Team Leader C. Thorough Analysis of Company's Requirements D. Mutual Trust in sharing info |
|
Definition
|
|
Term
Data collection to determine space and equipment needs in a mid-large company is not accurately colleced: A. from office mngr, B. 1-1 employee interviews C. from 2-3 typ. work groups D. w/standardized questionnaires answered by all employees |
|
Definition
ANSWER from 2-3 typical work groups |
|
|
Term
A client uses construction docs for a coffee kiosk to construct identical kiosks in additional locations w/out designer's consent. WHICH is FALSE? a.designer may be liable for mat. flaws for all kiosks b. client is legally bound to pay equivalent design |
|
Definition
ANSWER - the client in not legally bound to pay an equivalent design fee for each kiosk. In order to protect themselves, the ID should make sure that the contract and the drawings note the copyrighting of the design. |
|
|
Term
The "scope of services" should be defined in |
|
Definition
|
|
Term
At least two egress doorsways are required when the occupancy load is more than ____ and the travel distance to the egress exceeds _____. |
|
Definition
ANSWER 50 occupants, 75 feet |
|
|
Term
Per the egress code what is the minimum distance in feet between closed inner and outer doors in an entry foyer |
|
Definition
ANSWER 7' (4' clear req., + 3' of door width in open position |
|
|
Term
an exit light on a red wall should be: A. REd B. white on red C. white on black d. the greatest degree of color contrast |
|
Definition
ANSWER D greatest degree of color contrast |
|
|
Term
what does the Robinson-Patman Act, enforced by the Federal Trade Commision do? |
|
Definition
ANSWER B regulates safety & accessibility |
|
|
Term
While completing a finish schedule, a design assistant transposes 2 digits in a wall covering item number. The wrong wall covering is the same color palate as the original and looks terrific installed. The client is not happy and wants his original choice |
|
Definition
ANSWER A - enclose samples with specs (some controversy over this answer) |
|
|