Term
|
Definition
An ________ ________ _____ is placed on a floor plan to indicate that an elevation of the wall (or walls) is drawn somewhere in the set. The number on top of the line indicates the unique sequential number of the elevation drawing, and the number below the line indicates the sheet on which the drawing is placed. |
|
|
Term
|
Definition
A _____ _______ _____ is used to indicate where a section is cut through a portion of the construction. These can be used vertically or horizontally on plans, elevations, or even other sections to indicate that the drawing referred to shows a view that is 90° to the plane in which the mark is made. |
|
|
Term
|
Definition
A _____ _______ ____ is used to show that a detail of the portion circle is drawin. Unlike the section reference mark, this symbol indicates that the detail is drawin in the same plane of the circled part of the plan, rather than being view 90° to the cut line. |
|
|
Term
A) the reflected ceiling plan The reflected ceiling plan should show slab-to-slab partitions as well as ceiling high partitions. Although this information is usually indicated on wall-section details and sometimes on interior elevations, the reflected ceiling plan is the one place where it is all shown at once in an obvious manner. |
|
Definition
The full extent of slab-to-slab partitions on a project is best shown on A) the reflected ceiling plan B) the interior elevations C) wall section details D) the finish plan |
|
|
Term
C) interior designer The interior designer is ultimately responsible for coordinating the drawings of the various consultants |
|
Definition
Who is responsible for verifying that recessed downlights do not interfere with ductwork shown on the mechanical plans. A)mechanical engineer B) electrical engineer C) interior designer D) architect |
|
|
Term
D) both the interior designer and the mechanical engineer Although the mechanical engineer designs and locates the ductwork along with the supply-air diffusers and return-air grilles, the portions of the mechanical system that are exposed on the ceiling, like the return air grilles, should be shown on the interior design drawings. |
|
Definition
The locations of return air grilles are shown on the drawings provided by A) the architect B) the interior designer C) the mechanical engineer D) both the interior designer and the mechanical engineer |
|
|
Term
D) mechanical consultant An underfloor raceway sustem uses metal enclosures buried in the concrete floor slab. The selection would obviously involve the electrical consultant and the architect because this is part of the architectural work. The structural engineer would also be involved because the size, spacing, and configuration of thesystem affects the thicknes of the slab and its reinforcing. |
|
Definition
Who would be LEAST involved in the selection of an underfloor raceway system? A) electrical consultant B) structural engineer C) architect D) mechanical consultant |
|
|
Term
C) Contractor The contractor is the person typically responsible for submitting the plans and specifications to the building department, along with the application for permit. |
|
Definition
In most situations, the application for a building permit is made by the A) building owner B) client C) contractor D) interior designer |
|
|
Term
C) window schedule Because windows are part of the architectural work in a building, a window schedule would not be found on interior drawings. |
|
Definition
What type of schedule would be LEAST likely to be found in a set of interior design drawings? A) finish schedule B) millwork schedule C) window schedule D) equipment schedule |
|
|
Term
C) power plan Sometimes outlets are shown on the furniture plan and on the partition plan in small residential projects, but they would always be found on the power plan. |
|
Definition