Term
EQc7.1
Thermal Comfort
Design
intent? |
|
Definition
Thermal Comfort: Design
Provide a comfortable thermal environment that supports the productivity and well-being of building occupants |
|
|
Term
EQc7.1
Thermal Comfort: Design
Requirements? |
|
Definition
EQc7.1 Thermal Comfort: Design
Design HVAC systems and building envelope to meet ASHRAE 55-2004 (Thermal Comfort Conditions for Human Occupancy)
Demonstrate design compliance with Section 6.1.1 Documentation |
|
|
Term
EQc7.1
Thermal Comfort: Design
Strategies? |
|
Definition
EQc7.1 Thermal Comfort: Design
Establish comfort criteria per ASHRAE Standard 55-2004 that support the desired quality and occupant satisfaction with building performance.
Design building envelope and systems with the capability to deliver performance to the criteria under expected environmental and use conditions.
Evaluate air temp, radiant temp, air speed, relative humidity in an integrated fashion.
Coordinate criteria with EQp1, EQc1, EQc2 |
|
|
Term
EQc7.1
Thermal Comfort: Design
What is the Predicted Mean Vote (PMV) comfort model? |
|
Definition
From ASHRAE 55-2004
incorporates heat balance principles to relate personal + environmental thermal comfort factors based on a sensation scale that shows 7 levels from
+3 (hot) to -3 (cold) |
|
|
Term
EQc7.1
Thermal Comfort: Design
What are the 3 basic approaches to providing thermal comfort in a project space? |
|
Definition
Active Conditioning (mechanical systems)
Passive Systems (natural ventilation)
Mixed-mode - combination |
|
|
Term
EQc7.2
Thermal Comfort: Verification
Intent? |
|
Definition
EQc7.2
Thermal Comfort: Verification
Provide for the assessment of building thermal comfort over time. |
|
|
Term
EQc7.2 Thermal Comfort: Verification
Requirements? |
|
Definition
Implement thermal comfort survey of building occupants in 6-18 mos after occupancy.
Assessment to be anonymous
Agree to develop plan of action if more than 20% of responses are dissatisfied.
Plan of action to include measurement of relevant environmental variables in problem areas in accordance with ASHRAE 55-2004 |
|
|
Term
EQc7.2 Thermal Comfort: Verification
Strategies? |
|
Definition
Identify key areas of focus for occupant survey.
Anticipate provisions for analysis of environmental variables should the survey identify problems.
Provide occupants with a survey to gauge satisfaction; have them identify their location in the building by zone or voluntarily by exact location.
Corrective actions: control adjustments (setpoints, schedules, operating modes), diffuser airflow adjustments and solar control. |
|
|
Term
EQc8.1 Daylight and Views
Daylight 75% of spaces
intent? |
|
Definition
Provide building occupants with a connection between indoor spaces and the outdoors through the introduction of daylight and views into the regularly occupied areas of the building. |
|
|
Term
EQc8.1 Daylight and Views
Daylight 75% of Spaces
Requirements? |
|
Definition
Option 1: Glazing Factor Calculation
Min 2 % Glazing Factor in 75% of all spaces
Glazing Factor = Window Area x Window x Actual Tvis x Window
Floor Area Geometry Min. Tvis Ht Factor
Option 2: Daylight Simulation Model
Min Daylight Illumination level of 25 footcandles in 75% of all spaces.
Clear sky conditions at noon, on equinox at 30" above floor
Option 3: Daylight Measurements
Demonstrate through records of indoor light measurements that Min Daylight Illumination level of 25 footcandles has been achieved in 75% of all spaces.
Conduct measurements on a 10' x 10' grid. |
|
|
Term
EQc8.1 Daylight and Views
Daylight 75% of Spaces
Strategies?
|
|
Definition
- Maximize interior daylighting
- Building Orientation - long along N-S direction
- Shallow Floor Plates
- Increased Building Perimeter
- Exterior and interior shading devices to reduce glare - light shelves, fins, louvers, adjustable blinds
- Courtyards, atriums, clerestory windows, skylights
- High performance glazing
- Automatic photocell based controls
|
|
|
Term
EQc8.1 Daylight 75%
Heights for Vision Glazing and Daylight Glazing? |
|
Definition
Daylight Glazing: above 7'-6" high this is the most effective height for distributing daylight deep into the interior space
Vision Glazing: 2'-6" - 7'-6"
These areas are primarily used for viewing and lighting interior spaces closest to the building perimeter
Windows below 2'-6" do not contribute to daylighting and are excluded from these calculations. |
|
|
Term
EQc8.1
Daylighting 75%
Which areas are excluded from calculations of regularly occupied spaces? |
|
Definition
Support spaces:
Hallways
Foyers
Storage areas
Mech rooms
Restrooms |
|
|
Term
EQc8.1
Daylighting 75%
Name common glare control strategies |
|
Definition
Fixed Exterior Shading Devices
Light shelf, interior or exterior
Interior Blinds or shades
Fritted Glazing
Drapes
Electronic Blackout shading
Interior / Exterior fins or louvers |
|
|
Term
EQc8.1 Daylighting 75%
In a Daylight Simulation Model:
Grid at what height?
Grid at what spacing?
Date / time criteria?
Minimum footcandles? |
|
Definition
Daylight Simulation Model:
Grid at 30" high (desk height)
Grid at 2'x2' spacing
Clear sky conditions at Noon on equinox for project's geographic location
25 footcandles Minimum for 75% of regularly occupied spaces
|
|
|
Term
EQ c 8.1 Daylighting 75%
Exemplary Performance Credit? |
|
Definition
1 credit for exemplary performance under ID if project achieves 95% daylighting |
|
|
Term
EQc8.1 Daylighting 75%
How can this credit be approached so that 100% of each room does not have to meet the 2% daylight factor or the 25 footcandle reqt? |
|
Definition
The portion of the room that satisfies the reqt can be listed as such (Open Office-Daylight) and counted towards the percentage
The portion of the room not meeting the reqt (Open Office-Non-Daylight) would not count towards the compliant area total but would be considered as part of the total area calculations. |
|
|
Term
EQc8.1 Daylighting 75%
For the glazing factor calculation method (Option1), which data is required? |
|
Definition
Occupied space area (sf)
Area of each type of glazing (sidelighting vision, sidelighting daylight, flat skylight, sawtooth, vertical monitor) in sf
Tvis - Visible Light Transmittance for each glazing type (from manf)
|
|
|
Term
EQc8.2 Views for 90% of spaces
intent? |
|
Definition
EQc8.2 Views for 90% of spaces
Provide the building occupants with a connection between indoor and outdoors spaces through the introduction of daylight and views into the regularly occupied areas of the building |
|
|
Term
EQc8.2 Views for 90% of Spaces
Reqts? |
|
Definition
Achieve direct line of sight to the outdoors via vision glazing (2'-6" - 7'-6" AFF) in 90% of regularly occupied spaces:
Plan View: area is within sight lines drawn from perimeter vision glazing
Section view: direct sight line (42" AFF)can be drawn from the area to perimeter vision glazing
Line of sight may be drawn through interior glazing
Movable furniture and partitions are not included in scope of calculation
For private offices, the entire sf can count if 75% of area has direct sight line
For multi-occupant spaces, actual sf with direct line of sight counts |
|
|
Term
EQc8.2 Views for 90% of all Spaces
Strategies? |
|
Definition
Lower partition heights
interior glazing |
|
|
Term
EQc8.2
Views for 90% of Spaces
Exemplary Performance? |
|
Definition
This credit may be eligible for one credit under ID however there is no prescribed threshold
Projects will be evaluated on a case by case basis. |
|
|
Term
ID credits
Name 2 main types |
|
Definition
1. EXEMPLARY PERFORMANCE: Greatly exceeding the reqts of existing LEED credits = doubling credit reqts or next increment
2. Innovation strategies not addressed by existing LEED credits: comprehensive approach, have significant measurable environmental benefits. |
|
|
Term
IDc2
LEED AP
Submitted when?
Data reqd? |
|
Definition
Construction Submittal
Name of LEED AP
Name of LEED AP's company
Brief Description of LEED AP's project role(s)
Copy of LEED AP certificate |
|
|
Term
EQp1
Minimum IAQ Performance
Intent? |
|
Definition
EQp1: Minimum IAQ Performance
Establish minimum IAQ performance to enhance indoor air quality in buildings thus contributing to the comfort + well-being of the occupants |
|
|
Term
EQp1
Minimum IAQ performance
Reference Standard |
|
Definition
ASHRAE 62.1-2004
Sections 4-7
Chapter 5 for naturally ventilated buildings |
|
|
Term
EQp1
Minimum IAQ Performance
Strategies |
|
Definition
Active Mech system - meet ASHRAE 62.1-2004 sect 6 Ventilation rate procedure
Passive
Mixed |
|
|
Term
EQp2
Environmental Tobacco Smoke (ETS) Control
Intent? |
|
Definition
Minimize exposure of occupants, surfaces & ventilation air distribution systems to tobacco smoke. |
|
|
Term
|
Definition
In all cases: Locate designated smoking areas 25' from entries, outdoor air intake & operable windows
Option 1: Prohibit Smoking
Option 2: Prohibit smoking except in designated areas.
Locate smoking rooms to contain, capture & remove ETS from building. No recirculating air to other spaces; impermeable deck to deck partitions; create negative pressure with adjacent spaces
Option 3: Residential: Prohibit smoking in common areas.
Minimize ETS transfer between units by sealing all penetrations in ceilings & floors. Weatherstrip all doors; demonstrate acceptable sealing with blower door test.
|
|
|
Term
EQc1
Outdoor Air Delivery Monitoring
intent? |
|
Definition
Provide capacity for ventilation system monitoring to help sustain occupant comfort & well-being. |
|
|
Term
EQc1
Outdoor Air Delivery Monitoring
reqts? |
|
Definition
Install CO2 & airflow monitoring eqpt & feedback info to HVAC system of building automation system to trigger corrective action or trigger alarms so occupants can correct
at +/- 10% of design minimums
for ASHRAE 62.1 2004 |
|
|
Term
EQc1
Outdoor Air Delivery Monitoring
How is this measured?
Which type of rooms are measured and how?
|
|
Definition
Dense locations = 25 people/ 1000sf -- mount CO2 monitors between 3'-6' AFF in
Non-dense = less than 25 people/ 1000sf = provide a direct outdoor airflow measurement device and compare against design minimums (ASHRAE 62.1-2004)
Naturally ventilated spaces - use CO2 monitors mounted between 3'-6' AFF |
|
|
Term
EQc2
Increased Ventilation
intent? |
|
Definition
Provide additional outdoor air ventilation to improve occupant comfort, well-being and productivity |
|
|
Term
EQc2
Increased Ventilation
referenced standards |
|
Definition
ASHRAE 62.1-2004 - go 30% above reqts
Carbon Trust Good Practice Guide 237
CIBSE Applications Manual 10:2005 - Natural Ventilation in non-domestic buildings |
|
|
Term
EQc2
Increased Ventilation
Where does this credit make the most sense and why? |
|
Definition
Makes the most sense in mild climates.
Increases HVAC size and cost in hot humid or cold climates
Natural ventilation also makes more sense in mild climates
There's more cost for operable windows & louvers but occupants are happier. |
|
|
Term
EQc2
Increased ventilation
% above ASHRAE 62.1-2004?
based on how many cfm/person?
what is the breathing zone? |
|
Definition
30% above ASHRAE 62.1-2004
Based on benefits of 25 cfm/person
Breathing zone = 3'-6' AFF |
|
|
Term
EQc3.1
Construction IAQ Management Plan
During Construction
Intent? |
|
Definition
Reduce Indoor Air Quality Problems resulting from Construction / Renovation Process in order to help sustain the comfort and well-being of construction workers and building occupants. |
|
|
Term
EQc3.1
Construction IAQ Management Plan:
During Construction
Reqts? |
|
Definition
Develop & implement an IAQ mgmt plan:
During construction, meet or exceed control measures of SMACNA IAQ guidelines for buildings under construction, 1995, ch 3.
Protect stored on-site or installed absorptive materials from moisture damage.
If permanently installed air handlers are used during construction, use MERV 8 filters at all return air grilles (ASHRAE 52.2-1999)
Replace all filters prior to occupancy. |
|
|
Term
EQc3.1
Construction IAQ Management Plan
During Construction
Referenced Standards |
|
Definition
SMACNA IAQ guidelines for Occupied Buildings Under Construction
ANSI/ASHRAE 52.2- 1999 - Method of Testing General Ventilation Air Cleaning Devices for Removal Efficiency by Particle Size
(MERV values) |
|
|
Term
EQc3.2
Construction IAQ Management Plan
Before Occupancy
intent? |
|
Definition
Reduce indoor air quality problems resulting from the construction/ renovation process in order to help sustain the comfort and well-being of construction workers and building occupants. |
|
|
Term
EQc3.2
Construction IAQ Management Plan
Before Occupancy
Reqts? |
|
Definition
Option 1: FLUSHOUT
After construction, prior to occupancy, all finishes installed - total air volume of 14,000cuft of outdoor air per sf of floor area while maintaining indoor temp of 60% and humidity of 60%
OR FOR EARLIER OCCUPANCY, provide a minimum of 3500cuft of outdoor air per sf of floor air. Once occupied, provide 0.30cfm/sf of outside air or the design minimum outside air rate determined in EQp1. Flushout shall begin 3 hours prior to occupancy. Continue until 14000 has been delivered
OPTION 2 - AIR QUALITY TESTING
After construction ends and prior to occupancy, test using EPA standards, during normal occupied hours
One sample location per 25,000 sf taken in breathing zone ( 3'-6' AFF)over 4 hour period. |
|
|