Term
|
Definition
Site Selection: 1. template |
|
|
Term
|
Definition
DD & CC: 1. template 2. density calcs with area plan & location OR 3. area plan with bldg location, res zone and 10 services hghlighted |
|
|
Term
Sub Req For: SS Credit 3.1 |
|
Definition
Alt Transit - Public Transit Access: 1. Template 2. area drawin or map with bldg, rail statins and bus lines highlighted 3. distance between all of them and scale inclued |
|
|
Term
Sub Req For: SS Credit 3.2 |
|
Definition
Alt Transit: Bike Stor & change rms: 1. template - "distance to stor and showrs from entrance of bldg and no of tenants to meet 5% provided for |
|
|
Term
Sub Req For: SS Credit 3.3 |
|
Definition
Alt Transit - Parking Avail: 1. designer or other party 2. relevant sections of local zoning regs for occ group, zone and priority parking 3. template with lease that indicates parking guarantees |
|
|
Term
Sub Req For: WE Credit 1.1 & 1.2 |
|
Definition
Water Use Reducion, 20% & 30%: 1. template by MEP engineer based on EPAct of 1992 2. spreadsheet calcs for fixtures according to occ |
|
|
Term
|
Definition
Fund Cx: 1. template by cx authority & tenant 2. narrative and diagrams for HVAC system, shared parts of HVAC, scope of work, changes to overall system for tenant space |
|
|
Term
|
Definition
Min Energy Perf; 1. template by eng or arch 2. compliance with 90.1-2004 or local (most stringent) 3. if local codes used, demonstrate that local is more stringent |
|
|
Term
|
Definition
CFC Reduction in HVAC&R Equip: 1. template by eng 2. no cfcs in project scope of work |
|
|
Term
Sub Req For: EA Credit 1.1 |
|
Definition
Optimize Energy Performance, Lighting Power: 1. template by eng 2. lightin power density reduced below ASHRAE 3. lighting compliance doc in 90.1 2004 user manual 4. calculation to show % reduction in lighting power |
|
|
Term
Sub Req For: EA Credit 1.2 |
|
Definition
Optimize Energy Performance, Lightin Controls: 1. template by eng AND 2. narrative describing light controls 3. plan of light control zones, devices and lights controlled 4. shedule of light controls with model, type, etc |
|
|
Term
Sub Req For: EA Credit 1.3 - Option A |
|
Definition
Opt Energy Perf, HVAC: 1. templateby eng or arch 2. narrative of HVAC systems for tenant and bldg 3. HVAC equip schedule and plan to show HVAC in space |
|
|
Term
Sub Req For: EA Credit 1.3 - Option B |
|
Definition
Opt Energy Perf, HVAC: 1. template by eng or arch 2. copy of energy cost budget compliance form 3. narrative of HVAC system for tenant and bldg 4. HVAC Equip schedule and plans with HVAC in space |
|
|
Term
Sub Req For: EA Credit 1.4 |
|
Definition
Opt Energy Perf Equip and Appliances: 1. tempate 2. narrative of equip 3. equip schedule with rated power and which ones are EnergyStar Rated |
|
|
Term
|
Definition
Enhanced Cx: 1. template by owner and independant CA 2. 1 and 2 were executed 3. 3 and 4 are in place with a contract |
|
|
Term
Sub Req For: EA Credit 3 - projects with less than 75% total bldg area |
|
Definition
Energy Use, Measurement and Payment Accountability: 1. template by eng 2. description of metering equip installed 3. copy of lease to show energy costs paid by tenant |
|
|
Term
Sub Req For: EA Credit 3 - projects with more than 75% total bldg area |
|
Definition
Energy Use, Measurement and Payment Accountability: 1. template by eng 2. declare following IPMVP 3. copy of M&V plan with executive summary |
|
|
Term
|
Definition
Green Power: 1. template by owner 2. copy 2 yr utility purchase contract |
|
|
Term
|
Definition
Stor and Collection of Recyclables: 1 template 2. plan showing collction/storage area OR 3. letter from landlord outlining bldg's recycling program |
|
|
Term
Sub Req For: MR Credit 1.1 |
|
Definition
Tenant Space, Long Term Commitment: 1. template by owner 2. ownership or lease for min 10 yrs |
|
|
Term
Sub Req For: MR Credit 1.2 & 1.3 |
|
Definition
Building Reuse, maintain 40% or 60% interior non-structural components: 1. template 2. list retained elements |
|
|
Term
Sub Req For: MR Credit 2.1 & 2.2 |
|
Definition
Construction Waste Man, Divert 50% or 75% from landfill; 1. template 2. tabulate total waste, amounts diverted and where they were sent |
|
|
Term
Sub Req For: MR Credit 3.1 & 3.2 |
|
Definition
Resource Reuse, 5% or 10%: 1. template 2. list each material, costs and total costs |
|
|
Term
Sub Req For: Mr Credit 3.3 |
|
Definition
Resource Reuse, 30% Furniture: 1. template 2. list of reused furniture, replacement value |
|
|
Term
Sub Req For: MR Credit 4.1 & 4.2 |
|
Definition
Recycled Content, 10% or 20% (post = 1/2 pre): 1. template 2. list recyled content products 3. costs and % of post and pre 4. total cost of all materials for project (exclude mech or elec) |
|
|
Term
Sub Req For: MR Credit 4.1 & 4.2 |
|
Definition
Recycled Content, 10% or 20% (post = 1/2 pre): 1. template 2. list recyled content products 3. costs and % of post and pre 4. total cost of all materials for project (exclude mech or elec) |
|
|
Term
Sub Req For: MR Credit 4.1 & 4.2 |
|
Definition
Recycled Content, 10% or 20% (post = 1/2 pre): 1. template 2. list recyled content products 3. costs and % of post and pre 4. total cost of all materials for project (exclude mech or elec) |
|
|
Term
Sub Req For: MR Credit 4.1 & 4.2 |
|
Definition
Recycled Content, 10% or 20% (post = 1/2 pre): 1. template 2. list recyled content products 3. costs and % of post and pre 4. total cost of all materials for project (exclude mech or elec) |
|
|
Term
Sub Req For: MR Credit 4.1 & 4.2 |
|
Definition
Recycled Content, 10% or 20% (post = 1/2 pre): 1. template 2. list recyled content products 3. costs and % of post and pre 4. total cost of all materials for project (exclude mech or elec) |
|
|
Term
Sub Req For: MR Credit 5.1 |
|
Definition
Regional Mat'ls, 20% Manuf Regionally: 1. template 2. calcs for % regional materials 3. cost, % regional, distancefrom project to manuf 4. total cost of all project materials |
|
|
Term
Sub Req For: MR Credit 5.2 |
|
Definition
Regional Mat'ls, 10% Extracted and Manufactured Regionally: 1. template 2. calcs for % regionally extracted & Manuf materials 3. cost, % regional, distance from project to extraction and manufacture places 4. total cost of all project materials |
|
|
Term
|
Definition
Rapidly Renewable Materials: 1. template 2. calcs for % rapidly renwble products 3. cost, % of rapdily renewable parts 4. total cost of all project materials |
|
|
Term
|
Definition
Certified Wood: 1. template 2. list FSC-certified materials used 3. calcs for % FSC-cert materials, cost 4. total cost for all project materials 5. vendor's/manuf's FSC chain of custody certificate number |
|
|
Term
|
Definition
Min IAQ Perf: 1. template 2. calc summaries for oa vent rates, occ category, occ density, zoning. 3. existing bldgs - eng letter with info on mech equip |
|
|
Term
|
Definition
ETS Control: 1. template by tenant |
|
|
Term
|
Definition
Outdoor Air Delivery Monitoring: 1. template 2. summarize install, design and controls/zones for co or oa monitoring sys's |
|
|
Term
|
Definition
Increased Ventilation: a=mechanically ventilated b=naturally ventilated for a: 1. template by mech eng declaring 30% above ashrae 62.1-2004 2. calcs demonstrating this for B: 1. template by mech eng 2. defend why nat vent is a viable strategy for project 3. follow design recommendations by CIBSE. 4. diagrams and calcs based on CIBSE or analytical model |
|
|
Term
Sub Req For: EQ Credite 3.1 |
|
Definition
Constr IAQ Man Plan, During Constr: 1. template by gen contractor declaring IAQ plan during constr is implemented and list each air filter used at what phase 2. 18 photographs-6 on 3 difernt construction times - identify each smacna approach in each one 3. declare 5 approaches of smacna iaq guidelines - give a brief smmary of the approach you took to meet these. |
|
|
Term
Sub Req For: EQ Credit 3.2 OPTION A |
|
Definition
Constr IAQ Man Plan, Before Occ: 1. template 2. dates of flush outs 3. calcs o total air volumes and min vent volumes 4. copy of iaq test results |
|
|
Term
Sub Req For: EQ Credit 3.2 - OPTION Bq |
|
Definition
Constr IAQ Man Plan, Before Occ: 1. template by environmental consultant 2. compliance with testing and meeting below max concentration limits 3. copy of iaq test results. identify epa testing method used |
|
|
Term
Sub Req For: EQ Credit 4.1 |
|
Definition
low emit mat'ls - adhsives and sealants: 1. template 2. list adhesives used and prove they meet reqs 3. state VOC level, standard, mat'l classification, VOC limit |
|
|
Term
Sub Req For: EQ Credit 4.2 |
|
Definition
low emit mat'ls - paint and coatings: 1. template 2. list all paints used 3. state VOC level, standard,mat'l classification, VOC limit |
|
|
Term
Sub Req For: EQ Credit 4.3 |
|
Definition
low emit mat'ls - carpet sys's: 1. template 2. list all carpet sys's in space 3. state compliance |
|
|
Term
Sub Req For: EQ Credit 4.3 |
|
Definition
low emit mat'ls - carpet sys's: 1. template 2. list all carpet sys's in space 3. state compliance |
|
|
Term
Sub Req For: EQ Credit 4.4 |
|
Definition
low emit mat'ls - comp wod and lam adhesives: 1. template 2. list all comp wood products used 3. state that they contain no ureaformaldehyde resins 4. list all laminate adhesives 5. state they contain no u-formaldehyde 6. document that all core lam adhesive products contain none either |
|
|
Term
Sub Req For: EQ Credit 4.5 - OPTION A |
|
Definition
low - emit mat'ls - sys furn and seating: 1. template 2. list all syst furn/seating and give manuf, item, period of manufacture, compliance, EPA ETV test period 3. copy of certification with start/end dates. peiod covered must begin before and go thru actual manufactruing dates of product |
|
|
Term
Sub Req For: EQ Credit 4.5 - OPTON B |
|
Definition
low emit mat'ls -syst furn and seating: 1. template 2. listing with manufactureere, description, manufacture period, compliance and EPA ETV test perid |
|
|
Term
|
Definition
indoor chem and pollutant source control: 1. template 2. declare all of the reqs have been met |
|
|
Term
Sub Req For: EQ Credit 6.1 |
|
Definition
controllability of systemsn - lghting: 1. template by architect |
|
|
Term
Sub Req For: EQ Credit 6.2 |
|
Definition
controllability of systems - temperature and ventilation: 1. template by architect 2. declare temp and vent controls are provided |
|
|
Term
Sub Req For: EQ Credit 7.1 |
|
Definition
thermal comfort - compliance: 1. template by eng 2. compliance with ASHRAE 55-2004 3. section 6.1.1. too |
|
|
Term
Sub Req For: EQ Credit 7.2 |
|
Definition
thermal comfort - monitoring: 1. template by eng 2. identify comfort criteria, strat to ensure performance, descrip of monitoring system, process for corrective action |
|
|
Term
Sub Req For: EQ Credit 8.1 and 8.2 |
|
Definition
daylight and views - 75% or 90% of spaces: 1. template 2. area calcs for daylight zones 3. summarize daylight factor prediction calculations |
|
|
Term
Sub Req For: EQ Credit 8.3 |
|
Definition
daylight and views, views for 90% of seated space: 1. template 2. floor plans, sections highlighting ares with direct lin of sight 3. show partitions and perimeter windows when showig 42 in aff view |
|
|
Term
Sub Req For: ID Credit 1.1-1.4 |
|
Definition
Innovation in design: 1. proposals in templates online 2. include intent, reqs, subs and approaches |
|
|