Term
Req For: EQ Credit 8.1 & 8.2 |
|
Definition
do the following for min 75% reg occ'd areas: 1. min daylight factor 2% OR 1. daylight reducation & glare control devices 2. min 25 foot candles from computer simulation model 3. |
|
|
Term
|
Definition
1. direct line of sight thru vision glazing (2-6 to 7-6) 2. plan view - area in sight lines from perimeter vision glazing 3. section view - 42 in aff to perimeter vision glazing |
|
|
Term
|
Definition
1. ASHRAE 62.1-2004 2. natrually vent meet section 5.1 3. min outdoor air ventilation rate in 62.1-2004 4. if 62.1 can't be met, document what makes it impossible with min 10 cfm/person |
|
|
Term
Req for: EQ prereq 2 - Option A |
|
Definition
1 building prohibits smoking 2. exterior designated smoking areas min 25 ft from 1. entries, 2. outdoor air intakes, 3. operable windows |
|
|
Term
Req for: EQ prereq 2 - Option B |
|
Definition
1. no migration of ETS 2. designated smoking rooms that: a. remove ETS from bldg b. directly exhausted to outdoors c. deck-to-deck partitions d. negative pressure compared to other spaces e. average 5 PA f. min 1 PA with doors closed |
|
|
Term
|
Definition
1. trap dirt at entries 2. deck to deck partitions 3. separate outside exhausting - min 0.5 cu.ft./minute/sq.ft 4. no air recirculation 5. negaive pressure compared to other areas 6. containment drainse plumbed for hazardous liquid waste 7. new air filtration media before occupancy 8. min MERV 13 |
|
|
Term
Req For: EQ Credit 3 - Case B |
|
Definition
Case B = 75% area or more of total bldg continuous metering equipment for: 1. lighting systems & controls 2. cnstant & variable motor loads 3. VFD operation 4. chiller efficiency 5. cooling load 6. air & water economizer cycles 7. heat recover cycles 8. ai distribution static pressures 9. ventilation air volumes 10. boiler efficiencies 11. building related energy systemsn & equip 12. water riser & outdoor irrigation systems AND develop a M&V plan that follows option B,C, or D of IPMVP |
|
|
Term
|
Definition
Enhanced CX: 1. CA independent of design & const firms 2. CA involved prior to DD phase 3. review energy related systems contractor submittals 4. manual with info on re-cxing energy related systems 5. contract for training for operations and maint staff - incl plan to resolve issues 8-10 mo. after final acceptance. |
|
|
Term
Req for: EA Credit 3 - Case A |
|
Definition
area is less than 75% of total bldg: 1. install sub-metering equipment for energy use 2. lease with energy costs paid by tenant/not in base rent |
|
|
Term
Req for: EA Credit 1.3 - Option B |
|
Definition
Optimize energy perf - HVAC: 1. ASHRAE 90.1-2004 2. reduc design energy cost compared to cost budget in 90.1 3. 15% better perf = 1 point 4. 30% better perf = 2 pnts |
|
|
Term
Req for: EA Credit 1.3 - Option A |
|
Definition
Optimize Energy Performance, HVAC: (one or both of following:) 1. "equip efficiency" - meet E-Benchmark in HVAC system efficiecy requirements 2. "Zoning & control": a. all solar exposure has sepaate control zone b. separately zone interior spaces c. private off & special occs have sensory controls for HVAC response on demand |
|
|
Term
|
Definition
Optimize Energy Performance, Lighting Power: 1. ASHRAE 90.1-2004 2. reduce light power density under 90.1 3. space by space method 4. whole bldg allowance applied to entire tenant space 5. 15% reduction = 1 pnt 6. 35% reducation = 2 pnts |
|
|
Term
Req For: SS Credit 1 - Option F |
|
Definition
Light Pollution Reduction: 1. lower light levels and rations than in IESNA Recommended Practice Manual 2. shield exterior lights with 1000 lumens+ 3. lights with 3500 lumens+ meet FULL CUTOFF IESA CLASSIFICATION 4. max candela of interior lighting falls in property 5. anylight with distance of 2.5 x mounting ht from property boundary shielded so that light doesn't cross boundary |
|
|
Term
Req For: SS Credit 1 - Option D |
|
Definition
Heat Island Effect, Non-Roof: 1. bldg provides shad (or will in 5 years) 2. use light-colored/high albedo materials 3. min SRI 30 or 30% open grid pavement for site's non-roof imperv surfaces OR min 50% parking spaces underground or covered OR open-grid pavement systems (less than 50% impervious) for 50% of parking area |
|
|
Term
Req For: SS Credit 1 - Option C |
|
Definition
Stormwater Management, Treatment: 1. remove 80% TSS 2. remove 40% TP |
|
|
Term
Req For: SS Credit 1 - Option B |
|
Definition
Stormwater Management, Rate & Quantity: 1. "blding with less or eq 50% imperviousness" - implement stormwater management plan eq or less to 1.5/24 hr rate & quantity discharge OR 2. "greater than 50% imperviousness" - implement stormwater management plan reducing 1.5/24 hr rate and quantity discharge by 25% annual stormwater load falling on site |
|
|
Term
|
Definition
Certified Wood: 1. Min 50% new wood certified with FSC principles and criteria 2. applies to Furniture (div 12) |
|
|
Term
|
Definition
Rapidly Renewable Materials: 5% of total value of all blding materials from plants that are harvested within 10 year or shorter cycle |
|
|
Term
Ref Standard For: SS Credit 1 - Option C |
|
Definition
Site Selection - Stormwater Management, Treatment: Sources of Non-Point Pollution in Coastal Waters - Jan 93 |
|
|
Term
ASHRAE 55-2004 is referenced by what? |
|
Definition
EQ 7.1 Thermal Comfort, Compliance |
|
|
Term
ASHRAE 90.1-2004 is referenced by what? |
|
Definition
EA Prereq 2 Minimum Energy Performance AND EA 1.3 Optimize Energy Performance, HVAC |
|
|
Term
E-Benchmark is referenced by what? |
|
Definition
EA 1.3 Optimize Energy Performance, HVAC |
|
|
Term
ASHRAE 90.1-1999 (Energy Standard for Bldgs Except Low-Rise Res) is referenced by what? |
|
Definition
SS 1 Site Selection, Option K - On-site Renewable Energy |
|
|
Term
HERS Testing, Cal Low Rise Res is referenced by what? |
|
Definition
|
|
Term
Ref Standard For: SS Credit 1 - Option K |
|
Definition
Site Selection, On-Site Renewable Energy: ASHRAE 90.1-1999 (Energy Standard except low-rise res) |
|
|
Term
ASHRAE 52.2-1999 is referenced by what? |
|
Definition
EQ 3.1 Construction IAQ Man Plan, During Construction AND EQ 5 Indoor Chemical & Pollutant Source Control |
|
|
Term
Ref Standard For: EQ Credit 6.2 |
|
Definition
Controllability of Systems, Temperature & Ventilation: ASHRAE 62.1-2004 |
|
|
Term
Ref Standard For: EQ Credit 5 |
|
Definition
Indoor Chemical & Pollutant Source Control: ASHRAE 52.2-1999 (Methods for Testing Clean Air by Particle Size) |
|
|
Term
Ref Standard For: Eq Credit 3.1 |
|
Definition
Construction IAQ Man Plan, During Construction: 1. SMACNA Quidelines for Occuipied Bldgs 2. ANSRAE 52.2-1999 3. EPA Compendium (5 design approaches) |
|
|
Term
Ref Standard For: EQ Credit 2 |
|
Definition
1. ASHRAE 62.1-2004 2. Good Practice Guide 3. CIBSE Applications Manual 10-2005 |
|
|
Term
Ref Standard For: EA Prereq 2 |
|
Definition
Minimum Energy Performance: ASHRAE 90.1-2004 |
|
|
Term
CIBSE Applications Manual 10, 2005 is referenced by what? |
|
Definition
EQ 2 Increased Ventilation |
|
|
Term
Ref Standard For: EQ Prereq 1 |
|
Definition
Minimum IAQ Performance: ASHRAE 62.1-2004 |
|
|
Term
Ref Standard For: EQ Prereq 2 |
|
Definition
ETS Control: 1. ASTM 779-03 (Fan Blower Test) 2. HERS Testing (Cal Low Rise Res) |
|
|
Term
Ref Standard For: EQ Credit 3.2 |
|
Definition
Construciton IAQ Man Plan, Before Occ: EPA Compedium |
|
|
Term
ASTM E408-71 is referenced by what? |
|
Definition
SS 1, Option E Site Selection, Heat Island Effect, Roof |
|
|
Term
Sources of Non-Point Pollution in Coastal Waters, Jan-93 is referenced by what? |
|
Definition
SS 1, option C Site Selection, Stormwater Man, Treatment |
|
|
Term
IPMVP is referenced by what? |
|
Definition
EA 3 Energy Use, Measurement & Payment Accountability |
|
|
Term
Ref Standard For: EA Credit 1.3 |
|
Definition
Optimize Energy Performance, HVAC: 1. E-Benchmark 2. ASHRAE 90.1-2004 |
|
|
Term
ASHRAE 62.1-2004 references what? |
|
Definition
1. EQ Prereq 1 Min IAQ Performance 2. EQ 6.2 Controllability fo systems, temp/vent 3. EQ 2 increased ventilation 4. EQ outdoor air deliv monitoring |
|
|
Term
Ref Standard For: SS Credit 1 - Option J |
|
Definition
Site Selection, Water Use Reduction 20%: EPAct of 1992 |
|
|
Term
Ref Standard For: SS Credit 1 - Option E |
|
Definition
Site Selection, Heat Island Effect, Roof: 1. ASTM 1980-01 (Calculating Solar Reflectance) 2. ASTM E408-71 (Testing Normal Emmittance) 3. ASTM E903-96 (Solar Absorptance) 4. EPA Energy Star Roofing Guidelines |
|
|
Term
Good Practice Guide is referenced by what? |
|
Definition
EQ 2 Increased Ventilation |
|
|
Term
CRS Green-e Certification Program is referenced by what? |
|
Definition
|
|
Term
EPAct of 1992 is referenced by what? |
|
Definition
SS 1 - Option J Site Selection, Water Use Reduction 20% AND WE 1.1 & 1.2 |
|
|
Term
FSC Principles and Criteria is referenced by what? |
|
Definition
|
|
Term
SCAQMD Rule #1168 is referenced by what? |
|
Definition
EQ 4.1 Low-Emitting Materials - Adesives/Sealants |
|
|
Term
Ref Standard For: SS Credit 1 - Option F |
|
Definition
Site Selection, Light Pollutio Reduction: IESNA Recommended Practice Manual |
|
|
Term
Ref Standard For: EQ Credit 4.3 |
|
Definition
Low-Emitting Materials, Carpet Systems: CRI Green Label Plus |
|
|
Term
SMACNA IAQ Guidelines are referenced by what? |
|
Definition
EQ 3.1 Construction IAQ Man Plan, During Construction |
|
|
Term
SCAQMD Rule 1113 is referenced by what? |
|
Definition
EQ 4.2 Low-Emitting Materials, Paints and Coatings |
|
|
Term
Ref Standard For: MR Credit 4.1 & 4.2 |
|
Definition
Recycled Content 10% & 20%: FTC Guide for Marketing Claims |
|
|
Term
ASTM E1980-01 is referenced by what? |
|
Definition
SS 1, Option E Site Selection, Heat Island Effect, Roof |
|
|
Term
Ref Standard For: EA Credit 4 |
|
Definition
Green Power; CRS Green-e Program |
|
|
Term
ASTM 779-03 is referenced by what? |
|
Definition
|
|
Term
Ref Standard For: EQ Credit 1 |
|
Definition
Outdoor Air Delivry Monitoring: ASHRAE 62.1-2004 |
|
|
Term
ASTM E1903-97 Phase II ESA is referenced by what? |
|
Definition
SS 1, Option A Site Selection Brownfield Redevelopment |
|
|
Term
FTC Guides for use of Environmental Marketing Claims is referenced by what? |
|
Definition
MR 4.1 & 4.2 Recycled Content, 10% & 20% (post + pre-consumer) |
|
|
Term
Ref Standard For: EA Credit 3 |
|
Definition
Energy Use, Measurement & Payment Accountability: IPMVP |
|
|
Term
Green Seal 36 (GC-36) is referenced by what? |
|
Definition
EQ Credit 4.1 Low-Emitting Materials, Adhesives and Sealants |
|
|
Term
EPA Brownfields Definition is referenced by what? |
|
Definition
SS 1 - Option A Site Selection, Brownfield Redevelopment |
|
|
Term
Green Seal Standard GS-11 is referenced by what? |
|
Definition
EQ 4.2 Low-Emit Matls - Paints and Coatings |
|
|
Term
ASTM E903-96 is referenced by what? |
|
Definition
SS Credit 1 - Option E Site Selection - Heat Island Effect, Roof |
|
|
Term
CRI Green Label Plus Testing Program is referenced by what? |
|
Definition
EQ 4.3 Low-Emit Matls, Carpet Systems |
|
|
Term
Req For: ID Credit 1.1 thur 1.4 |
|
Definition
Innovation in Design: identify the following: 1. intent 2. requirments 3. submittals 4. strategies (design approach) |
|
|
Term
|
Definition
LEED Accredited Professional: min 1 participant of team has passed LEED AP Exam |
|
|
Term
EPA Compendium is referenced by what? |
|
Definition
EQ 3.1 & EQ 3.2 Construction IAQ Man Plan, During Construction & Before Occupancy |
|
|
Term
Green Seal Standard GS-03 is referenced by what? |
|
Definition
EQ 4.2 Low-Emit Matls - Paints/Coatings |
|
|
Term
IESNA Recommended Practice Manual is referenced by what? |
|
Definition
SS 1 - Option F Site Selection, Light Pollution Reduction |
|
|
Term
Ref Standard For: MR Credit 7 |
|
Definition
Certified Wood: FSC Principles and Criteria |
|
|
Term
Ref Standard For: EQ Credit 7.1 |
|
Definition
Thermal Comfort, Compliance: ASHRAE 55-2004 |
|
|
Term
Ref Standard For: EQ Credit 4.5 |
|
Definition
Low-Emit Mat'ls, Sys Furniture/Seating: 1. Greenguard Certification Program 2. EPA ETV (Test Protocol to Measure VOC Emissions) |
|
|
Term
EPA ETV Testing Protocol is referenced by what? |
|
Definition
EQ Credit 4.5 Low-Emit Mat'ls - Sys Furn/Seating |
|
|
Term
EPA Energy Star Roofing Guidelines are referenced by what? |
|
Definition
SS 1 - Option E Site Selection, Heat Island Effect-Roof |
|
|
Term
Ref Standard For: SS Credit 1 - Option A |
|
Definition
Site Selection - Brownfield Redevelopment: 1. ASTM E1903-97 Phase II ESA 2. EPA Brownfields Definition |
|
|
Term
Ref Standard For: EQ Credit 4.2 |
|
Definition
Low-Emit Mat'ls, Paints/Coatings: 1. GS-11 2. GS-03 3. SCAQMD Rule 1113 |
|
|
Term
Ref Standard For: EQ Credit 4.1 |
|
Definition
Low-Emit Mat'ls, Adhesives/Sealants: 1. SCAQMD Rule 1168 2. GC-36 |
|
|
Term
Greenguard Certification Program is referenced by what? |
|
Definition
EQ 4.5 Low-Emit Mat'ls, Sys Furn/Seating |
|
|
Term
|
Definition
Green Power: 1. 50% electricity from renewable sources 2. min 2 year contract 3. Source defined by: 1. Green-e certified power marketer 2. Green-e accredited utility program 3. Green-e Tradable renewable certificates 4. supply meeting Green-e renewable power def |
|
|
Term
|
Definition
Low-Emit Mat'ls - Paints/Coatings: 1. GS-11 2. GS-03 3.SCAQMD Rule 1113 |
|
|
Term
|
Definition
Low-Emit Mat'ls - Adhesives/Sealants: 1. SCAQMD Rule 1168 2. GC-36 |
|
|
Term
Req For: EQ Credit 2 - for Mechanically Ventilated Spaces |
|
Definition
Increased Ventilation: 1. min 30% increase of outdoor air vent over ASHRAE 62.1-2004 AND 1. meet CIBSE Applications Manual 10-2005 recommendations OR 2. analytic model to show that 90% of occupied spaces naturally ventilate |
|
|
Term
|
Definition
Outdoor Air Delivery Monitoring: 1. permanent monitoring systems for vent system 2. mech vent for densely occupied spaces (25 people/1000 s.f. or more) - CO2 Sensor in each densely occupie space 3. other mech vented spaces - measure outdoor airflow and get within 15% of design min outdoor air rate 4. for nat vent spaces - CO2 sensor within each nat vented space |
|
|
Term
To meet EQ Prereq 2 Option B, how must the smoking room perform? |
|
Definition
1. test differential air pressure 2. measure 15 minutes total -1 measurement every 10 seconds 3. test configured for worst case conditions of transport air to adjacent spaces |
|
|
Term
|
Definition
Construction IAQ Man Plan, During Construction: 1. IAQ Man Plan for Construction and Pre-Occ Phases 2. SMACNA IAQ Guidelines 3. Protect absorptive materials from moisture 4. MERV 8 minimum 5. Replace filtration prior to occupance 6. Coordinate with EQ 3.2 & 5 (single set of final filtration media) |
|
|
Term
Req For: EQ Credit 3.2 - Option B |
|
Definition
Construction IAQ Man Plan - Before Occupancy - IAQ Test Procedure: 1. Baseline IAQ Testing according to EPA Compendium 2. if max concentration limits are exceeded, flush out and retest 3. retest same locations each time |
|
|
Term
|
Definition
Thermal Comfort, Compliance: ASHRAE 55-2004 |
|
|
Term
|
Definition
Thermal Comfort, Monitoring: permanent monitoring system to verify meeting ASHRAE 55-2004 conditions |
|
|
Term
|
Definition
Controllability of Systems, Temp/Vent: 1.min 50% have indiv adjustmnt control 2. shared multi-occupant spaces must share controls |
|
|
Term
|
Definition
Controllability of Systems, Lighting: 1. lighting controls for 90% of occupants 2. shared occupant spaces must share controls |
|
|
Term
|
Definition
Low-Emit Mat'ls, Comp Wood/Lam Adhesives: 1. contain NO ADDED UREA-FORMALEHYDE 2. excludes EQ 4.5 products (sys furn/seating) |
|
|
Term
|
Definition
Low-Emit Mat'ls, Carpet Systems: 1. carpet meets CRI Green Label Plus Testing 2. pad meets same standard 3. adhesive meet EQ 4.1 |
|
|
Term
Req For: EQ Credit 2 - for Naturally Ventilated Spaces |
|
Definition
Increased Ventilation: 1. Good Practice Guide 237-1998 2. Follow diagraming in CIBSE Application Manual 10-2005 AND ONE OF THESE: 3. MEET CIBSE Applications Manual 10-2005 recommendations OR 4. analytic model to show nat vent for 90% of occupied spaces |
|
|
Term
Req For: EQ Prereq 2 - Option C |
|
Definition
ETS Control for Muli-Unit Residential: 1. minimize uncontrolled pathways for ETS Xfer 2. seal wall, ceiling, floor penetratins 3. seal vertical chases 4. weather strip doors leading to common hallways |
|
|
Term
Req For: EQ Credit 3.2 - Option A |
|
Definition
Construction IAQ Man Plan, Before Occupancy - Flush Out Procedure: After construction and int finishes installed: 1. install new filtration media 2. flush out bldg 3. total air volume 14,000 cu.ft. outdoor air per s/f floor area 4. min 60 deg F 5. max rel hum 60 6. occupy after min 3500 cu ft outdoor air/sf floor area to space 7. vent min .30 cfm/sf ouside air OR design min outside air rate (the greater of the two) 8. min 3 hours prior to occ 9. do this till 14,000 cuft/sf is met |
|
|
Term
|
Definition
Low-Emit Mat'ls, Sys Furn/Seating: option A - Greengaurd IAQ Certified option B - EPA ETV Test Protocol, testing in independent air quality testing lab |
|
|
Term
Exceptions to EQ Credit 8.1 & 8.2? |
|
Definition
yes - Exceptions for areas where tasks would be hindered by the use of daylight will be considered on their merits |
|
|
Term
Req For: MR Credit 1.2 & 1.3 |
|
Definition
Building Reuse - 40% & 60% Int non-struc comp's: 1. maintain min 40% for 1 pnt 2. maintina min 60% for 2 pnts 3. measure by area of walls, flooring, ceilings |
|
|
Term
|
Definition
Tenant Space, Long Term Commitment: commit to min 10 year stay |
|
|
Term
|
Definition
Stor/Collect Recyclables: provide space to collect at min 1. paper 2. plastic 3. glass 4. metals 5. corrugated cardboard |
|
|
Term
|
Definition
optimize Energy Perfomance, Equip & Apps: use energy star rated equipment that is eligible for the rating: 1. 70% for 1 pnt 2. 90% fo4 2 pnts |
|
|
Term
|
Definition
Optimize Energy Performance, Lighting Controls: 1. daylight responsive controls in reg occ'd spaces 2. install within 15 ft of windows and under skylights |
|
|
Term
|
Definition
CFC Reduction in HVAC&R Equip: Zero use of CFC-based refrigerants in scope of work |
|
|
Term
Req For: MR Credit 2.1 & 2.2 |
|
Definition
Construction Waste Management, Divert 50% & 75% from landfill: 1. construction waste management plan 2. quantify mat'l diversion goals 3. recycle or salvage min 50% for 1 pnt 4. recycle or salvage min 75% for 2 pnts 5. calcs can be by weight or volume, but must be consistent |
|
|
Term
|
Definition
Site Selection: 1. LEED certified building - 3 pnts OR 2. blding that has 2 or more of 12 options - up to 3 points |
|
|
Term
Req For: SS Credit 1 - Option A |
|
Definition
Brownfield Redevelopment: 1. ASTM E1903-97 ESA OR 2. classified as a brownfield by gov't agency and remediation completed |
|
|
Term
Req For: SS Credit 1 - Option G |
|
Definition
Site Selection, Water Efficient Irrigation - Reduced Potable Water Consumption: 1. high-efficiency irrigation OR 2. captured/recylced site water 3. reduce potable water use by 50% |
|
|
Term
Req For: SS Credit 1 - Option H |
|
Definition
Site Selection, Water Efficient Irrigation - No Potable Use/No Irrigation: 1. nopotable use - only use of recycled rain or site water 2. excluding watering to establish plants OR 3. no irrigation that is permanent on site |
|
|
Term
Req For: SS Credit 1 - Option I |
|
Definition
Site Selection, Innovative Wastewater Technologies: 1. Reduce Potable Water for Sewage by 50% 2. treat 100% onsite water to tertiary standards |
|
|
Term
Req For: SS Credit 1 - Option J |
|
Definition
Site Selection, Water Use Reduction 20%: 1. meets 20% reduction 2. ongoing plan to require compliance in future |
|
|
Term
Req For: SS Credit 1 - Option K |
|
Definition
Site Selection, On-Site Renewable Energy: 1. % total bldg energy use supplied by on-site renewable energy systems: 5% for 1/2 pnt, 10% for 1 point |
|
|
Term
Req For: SS Credit 1 - Option L |
|
Definition
Other Qunatifiable Env Performance: 1. in place at time of submittal 2. reference requirements from other LEED rating systems 3. up to 3 points total |
|
|
Term
|
Definition
Alt Transit - Public Trans Access: 1. 1/2 mile from railway 2. 1/4 mile from 2 or more bus lines |
|
|
Term
|
Definition
Alt Transit - Public Transit Access: 1. 1/2 mile from rail 2. 1/4 mile from 2 bus lines |
|
|
Term
|
Definition
DD & CC: bldg in walkable community with: 1. min density 60,000 sf/acre net (2 story dwntwn dev) OR 2. bldg is 1/2 mile from res zone/neighborhood with average density of 10/acre net AND 3. 1/2 mile pedestrian access to minimum of 10 basic services |
|
|
Term
|
Definition
Alt Transit - bike tor and hanging rooms: bike stor and change rooms within 200 yds for 5% tenant occs |
|
|
Term
Req For: SS Credit 3.3 - Case A for less than 75% gross blding square footage |
|
Definition
Alt Transit - parking availability: 1. do not exceed zoning regulations for min no of parking spaces AND 2. priority parking for car-pools for 5% tenant occs OR 3. no parking provided for tenant occs |
|
|
Term
Req For: SS Credit 3.3 - Case B for 75% or over gross bldg s/f |
|
Definition
Alt trnsit - parking availability: 1. do not exceed min parking zoning reqs AND 2. priority parking for car-ools for 5% BLDG occs OR 1. no new parking AND 2. priority parking for car-pools for 5% BLDG occs |
|
|
Term
|
Definition
Water Use Reduction, 20%: 1. us 20% less water than baseline calc 2. meet EPAct of 1992 |
|
|
Term
|
Definition
Water Use Reduction, 30%: 1. meet EPAct of 1992 for fixture performance 2. comined, use 30% less water than baseline calc |
|
|
Term
|
Definition
fundamental cx: following items are completed by cx team: 1. cx leads process - not directly resp for design or construction 2. document owner's project reqs & basis of design for energy systems 3. incorporate cx reqs into CD's 4. develop CX plan 5. verify that systems meet owners project requirements and intent 6. CX Report |
|
|
Term
|
Definition
min energy perf: ASHRAE 990.1-2004 or local energy code (most stringent) |
|
|
Term
Req For: SS Credit 1 - Option E |
|
Definition
Site Selection - Heat Island Effect, Roof: 1. roofing meets or exceeds SRI in table for min 75% total roof surface OR 2. installed green roof for 50% of roof area OR 3. bldg has combo of green roof and SRI greater than or eq to table referenced [SEE REFERENCED TABLE & REFERENCED EQUATION] |
|
|
Term
|
Definition
Regional Mat's - 10% extract/manuf Regionally: 1. in addition to 5.1 2. 10% of mat'ls/furn for project manufactured AND extracted within 500 miles of project |
|
|
Term
|
Definition
Regional Mat'ls - 20% manuf Regionally: 1. minimum 20% combined value of construction/furn manufactured within 500 mile radius |
|
|
Term
Req For: MR Credit 4.1 & 4.2 |
|
Definition
Recycled Content, 10% & 20% (post = 1/2 pre): 1. incl furniture 2. percentages of total value of mat'ls i project 3. 10% = 1 point 4. 20% = 2 pnts |
|
|
Term
|
Definition
Resource Reuse, 30% (furniture): 1. salvaged 2. refurbished 3. used furniture 4. 30% of total furniture budget |
|
|
Term
Req For: MR Credit 3.1 & 3.2 |
|
Definition
Resource Reuse, 5% or 10%: 1. salvaged 2. refurbished 3. reused mat'ls 4. 5% - 1 pnt 5 10% - 2 pnts 6 NOT INCL FURNITURE! |
|
|
Term
What systems must be Commissioned? |
|
Definition
min of: 1. HVAC&R systems and controls 2. lighting controls (also daylight) 3. domestic hot water sys's 4. renewable energy systems |
|
|