Shared Flashcard Set

Details

LEED-CI - Reqs & Ref Stds - V1
Referenced Standards and Requirements for each LEED-CI Credit
129
Architecture
Graduate
11/09/2008

Additional Architecture Flashcards

 


 

Cards

Term
Req For:
EQ Credit 8.1 & 8.2
Definition
do the following for min 75% reg occ'd areas:
1. min daylight factor 2%
OR
1. daylight reducation & glare control devices
2. min 25 foot candles from computer simulation model
3.
Term
Req for:
EQ credit 8.3
Definition
1. direct line of sight thru vision glazing (2-6 to 7-6)
2. plan view - area in sight lines from perimeter vision glazing
3. section view - 42 in aff to perimeter vision glazing
Term
Req for:
EQ Prereq 1
Definition
1. ASHRAE 62.1-2004
2. natrually vent meet section 5.1
3. min outdoor air ventilation rate in 62.1-2004
4. if 62.1 can't be met, document what makes it impossible with min 10 cfm/person
Term
Req for:
EQ prereq 2 - Option A
Definition
1 building prohibits smoking
2. exterior designated smoking areas min 25 ft from 1. entries, 2. outdoor air intakes, 3. operable windows
Term
Req for:
EQ prereq 2 - Option B
Definition
1. no migration of ETS
2. designated smoking rooms that:
a. remove ETS from bldg
b. directly exhausted to outdoors
c. deck-to-deck partitions
d. negative pressure compared to other spaces
e. average 5 PA
f. min 1 PA with doors closed
Term
Req for:
EQ Credit 5
Definition
1. trap dirt at entries
2. deck to deck partitions
3. separate outside exhausting - min 0.5 cu.ft./minute/sq.ft
4. no air recirculation
5. negaive pressure compared to other areas
6. containment drainse plumbed for hazardous liquid waste
7. new air filtration media before occupancy
8. min MERV 13
Term
Req For:
EQ Credit 3 - Case B
Definition
Case B = 75% area or more of total bldg
continuous metering equipment for:
1. lighting systems & controls
2. cnstant & variable motor loads
3. VFD operation
4. chiller efficiency
5. cooling load
6. air & water economizer cycles
7. heat recover cycles
8. ai distribution static pressures
9. ventilation air volumes
10. boiler efficiencies
11. building related energy systemsn & equip
12. water riser & outdoor irrigation systems
AND
develop a M&V plan that follows option B,C, or D of IPMVP
Term
Req for:
EA Credit 2
Definition
Enhanced CX:
1. CA independent of design & const firms
2. CA involved prior to DD phase
3. review energy related systems contractor submittals
4. manual with info on re-cxing energy related systems
5. contract for training for operations and maint staff - incl plan to resolve issues 8-10 mo. after final acceptance.
Term
Req for:
EA Credit 3 - Case A
Definition
area is less than 75% of total bldg:
1. install sub-metering equipment for energy use
2. lease with energy costs paid by tenant/not in base rent
Term
Req for:
EA Credit 1.3 - Option B
Definition
Optimize energy perf - HVAC:
1. ASHRAE 90.1-2004
2. reduc design energy cost compared to cost budget in 90.1
3. 15% better perf = 1 point
4. 30% better perf = 2 pnts
Term
Req for:
EA Credit 1.3 - Option A
Definition
Optimize Energy Performance, HVAC:
(one or both of following:)
1. "equip efficiency" - meet E-Benchmark in HVAC system efficiecy requirements
2. "Zoning & control":
a. all solar exposure has sepaate control zone
b. separately zone interior spaces
c. private off & special occs have sensory controls for HVAC response on demand
Term
Req for:
EA Credit 1.1
Definition
Optimize Energy Performance, Lighting Power:
1. ASHRAE 90.1-2004
2. reduce light power density under 90.1
3. space by space method
4. whole bldg allowance applied to entire tenant space
5. 15% reduction = 1 pnt
6. 35% reducation = 2 pnts
Term
Req For:
SS Credit 1 - Option F
Definition
Light Pollution Reduction:
1. lower light levels and rations than in IESNA Recommended Practice Manual
2. shield exterior lights with 1000 lumens+
3. lights with 3500 lumens+ meet FULL CUTOFF IESA CLASSIFICATION
4. max candela of interior lighting falls in property
5. anylight with distance of 2.5 x mounting ht from property boundary shielded so that light doesn't cross boundary
Term
Req For:
SS Credit 1 - Option D
Definition
Heat Island Effect, Non-Roof:
1. bldg provides shad (or will in 5 years)
2. use light-colored/high albedo materials
3. min SRI 30 or 30% open grid pavement for site's non-roof imperv surfaces
OR
min 50% parking spaces underground or covered
OR
open-grid pavement systems (less than 50% impervious) for 50% of parking area
Term
Req For:
SS Credit 1 - Option C
Definition
Stormwater Management, Treatment:
1. remove 80% TSS
2. remove 40% TP
Term
Req For:
SS Credit 1 - Option B
Definition
Stormwater Management, Rate & Quantity:
1. "blding with less or eq 50% imperviousness" - implement stormwater management plan eq or less to 1.5/24 hr rate & quantity discharge
OR
2. "greater than 50% imperviousness" - implement stormwater management plan reducing 1.5/24 hr rate and quantity discharge by 25% annual stormwater load falling on site
Term
Req For:
MR Credit 7
Definition
Certified Wood:
1. Min 50% new wood certified with FSC principles and criteria
2. applies to Furniture (div 12)
Term
Req For
MR Credit 6
Definition
Rapidly Renewable Materials:
5% of total value of all blding materials from plants that are harvested within 10 year or shorter cycle
Term
Ref Standard For:
SS Credit 1 - Option C
Definition
Site Selection - Stormwater Management, Treatment:
Sources of Non-Point Pollution in Coastal Waters - Jan 93
Term
ASHRAE 55-2004 is referenced by what?
Definition
EQ 7.1
Thermal Comfort, Compliance
Term
ASHRAE 90.1-2004 is referenced by what?
Definition
EA Prereq 2
Minimum Energy Performance
AND
EA 1.3
Optimize Energy Performance, HVAC
Term
E-Benchmark is referenced by what?
Definition
EA 1.3
Optimize Energy Performance, HVAC
Term
ASHRAE 90.1-1999 (Energy Standard for Bldgs Except Low-Rise Res) is referenced by what?
Definition
SS 1
Site Selection, Option K - On-site Renewable Energy
Term
HERS Testing, Cal Low Rise Res is referenced by what?
Definition
EQ Prereq 2
ETS Control
Term
Ref Standard For:
SS Credit 1 - Option K
Definition
Site Selection, On-Site Renewable Energy:
ASHRAE 90.1-1999 (Energy Standard except low-rise res)
Term
ASHRAE 52.2-1999 is referenced by what?
Definition
EQ 3.1
Construction IAQ Man Plan, During Construction
AND
EQ 5
Indoor Chemical & Pollutant Source Control
Term
Ref Standard For:
EQ Credit 6.2
Definition
Controllability of Systems, Temperature & Ventilation:
ASHRAE 62.1-2004
Term
Ref Standard For:
EQ Credit 5
Definition
Indoor Chemical & Pollutant Source Control:
ASHRAE 52.2-1999 (Methods for Testing Clean Air by Particle Size)
Term
Ref Standard For:
Eq Credit 3.1
Definition
Construction IAQ Man Plan, During Construction:
1. SMACNA Quidelines for Occuipied Bldgs
2. ANSRAE 52.2-1999
3. EPA Compendium (5 design approaches)
Term
Ref Standard For:
EQ Credit 2
Definition
1. ASHRAE 62.1-2004
2. Good Practice Guide
3. CIBSE Applications Manual 10-2005
Term
Ref Standard For:
EA Prereq 2
Definition
Minimum Energy Performance:
ASHRAE 90.1-2004
Term
CIBSE Applications Manual 10, 2005 is referenced by what?
Definition
EQ 2
Increased Ventilation
Term
Ref Standard For:
EQ Prereq 1
Definition
Minimum IAQ Performance:
ASHRAE 62.1-2004
Term
Ref Standard For:
EQ Prereq 2
Definition
ETS Control:
1. ASTM 779-03 (Fan Blower Test)
2. HERS Testing (Cal Low Rise Res)
Term
Ref Standard For:
EQ Credit 3.2
Definition
Construciton IAQ Man Plan, Before Occ:
EPA Compedium
Term
ASTM E408-71 is referenced by what?
Definition
SS 1, Option E
Site Selection, Heat Island Effect, Roof
Term
Sources of Non-Point Pollution in Coastal Waters, Jan-93 is referenced by what?
Definition
SS 1, option C
Site Selection, Stormwater Man, Treatment
Term
IPMVP is referenced by what?
Definition
EA 3
Energy Use, Measurement & Payment Accountability
Term
Ref Standard For:
EA Credit 1.3
Definition
Optimize Energy Performance, HVAC:
1. E-Benchmark
2. ASHRAE 90.1-2004
Term
ASHRAE 62.1-2004 references what?
Definition
1. EQ Prereq 1
Min IAQ Performance
2. EQ 6.2
Controllability fo systems, temp/vent
3. EQ 2
increased ventilation
4. EQ
outdoor air deliv monitoring
Term
Ref Standard For:
SS Credit 1 - Option J
Definition
Site Selection, Water Use Reduction 20%:
EPAct of 1992
Term
Ref Standard For:
SS Credit 1 - Option E
Definition
Site Selection, Heat Island Effect, Roof:
1. ASTM 1980-01 (Calculating Solar Reflectance)
2. ASTM E408-71 (Testing Normal Emmittance)
3. ASTM E903-96 (Solar Absorptance)
4. EPA Energy Star Roofing Guidelines
Term
Good Practice Guide is referenced by what?
Definition
EQ 2
Increased Ventilation
Term
CRS Green-e Certification Program is referenced by what?
Definition
EA 4
Green Power
Term
EPAct of 1992 is referenced by what?
Definition
SS 1 - Option J
Site Selection, Water Use Reduction 20%
AND
WE 1.1 & 1.2
Term
FSC Principles and Criteria is referenced by what?
Definition
MR 7
Certified Wood
Term
SCAQMD Rule #1168 is referenced by what?
Definition
EQ 4.1
Low-Emitting Materials - Adesives/Sealants
Term
Ref Standard For:
SS Credit 1 - Option F
Definition
Site Selection, Light Pollutio Reduction:
IESNA Recommended Practice Manual
Term
Ref Standard For:
EQ Credit 4.3
Definition
Low-Emitting Materials, Carpet Systems:
CRI Green Label Plus
Term
SMACNA IAQ Guidelines are referenced by what?
Definition
EQ 3.1
Construction IAQ Man Plan, During Construction
Term
SCAQMD Rule 1113 is referenced by what?
Definition
EQ 4.2
Low-Emitting Materials, Paints and Coatings
Term
Ref Standard For:
MR Credit 4.1 & 4.2
Definition
Recycled Content 10% & 20%:
FTC Guide for Marketing Claims
Term
ASTM E1980-01 is referenced by what?
Definition
SS 1, Option E
Site Selection, Heat Island Effect, Roof
Term
Ref Standard For:
EA Credit 4
Definition
Green Power;
CRS Green-e Program
Term
ASTM 779-03 is referenced by what?
Definition
EQ Prereq 2
ETS Control
Term
Ref Standard For:
EQ Credit 1
Definition
Outdoor Air Delivry Monitoring:
ASHRAE 62.1-2004
Term
ASTM E1903-97 Phase II ESA is referenced by what?
Definition
SS 1, Option A
Site Selection Brownfield Redevelopment
Term
FTC Guides for use of Environmental Marketing Claims is referenced by what?
Definition
MR 4.1 & 4.2
Recycled Content, 10% & 20% (post + pre-consumer)
Term
Ref Standard For:
EA Credit 3
Definition
Energy Use, Measurement & Payment Accountability:
IPMVP
Term
Green Seal 36 (GC-36) is referenced by what?
Definition
EQ Credit 4.1
Low-Emitting Materials, Adhesives and Sealants
Term
EPA Brownfields Definition is referenced by what?
Definition
SS 1 - Option A
Site Selection, Brownfield Redevelopment
Term
Green Seal Standard GS-11 is referenced by what?
Definition
EQ 4.2
Low-Emit Matls - Paints and Coatings
Term
ASTM E903-96 is referenced by what?
Definition
SS Credit 1 - Option E
Site Selection - Heat Island Effect, Roof
Term
CRI Green Label Plus Testing Program is referenced by what?
Definition
EQ 4.3
Low-Emit Matls, Carpet Systems
Term
Req For:
ID Credit 1.1 thur 1.4
Definition
Innovation in Design:
identify the following:
1. intent
2. requirments
3. submittals
4. strategies (design approach)
Term
Req For:
ID Credit 2
Definition
LEED Accredited Professional:
min 1 participant of team has passed LEED AP Exam
Term
EPA Compendium is referenced by what?
Definition
EQ 3.1 & EQ 3.2
Construction IAQ Man Plan, During Construction & Before Occupancy
Term
Green Seal Standard GS-03 is referenced by what?
Definition
EQ 4.2
Low-Emit Matls - Paints/Coatings
Term
IESNA Recommended Practice Manual is referenced by what?
Definition
SS 1 - Option F
Site Selection, Light Pollution Reduction
Term
Ref Standard For:
MR Credit 7
Definition
Certified Wood:
FSC Principles and Criteria
Term
Ref Standard For:
EQ Credit 7.1
Definition
Thermal Comfort, Compliance:
ASHRAE 55-2004
Term
Ref Standard For:
EQ Credit 4.5
Definition
Low-Emit Mat'ls, Sys Furniture/Seating:
1. Greenguard Certification Program
2. EPA ETV (Test Protocol to Measure VOC Emissions)
Term
EPA ETV Testing Protocol is referenced by what?
Definition
EQ Credit 4.5
Low-Emit Mat'ls - Sys Furn/Seating
Term
EPA Energy Star Roofing Guidelines are referenced by what?
Definition
SS 1 - Option E
Site Selection, Heat Island Effect-Roof
Term
Ref Standard For:
SS Credit 1 - Option A
Definition
Site Selection - Brownfield Redevelopment:
1. ASTM E1903-97 Phase II ESA
2. EPA Brownfields Definition
Term
Ref Standard For:
EQ Credit 4.2
Definition
Low-Emit Mat'ls, Paints/Coatings:
1. GS-11
2. GS-03
3. SCAQMD Rule 1113
Term
Ref Standard For:
EQ Credit 4.1
Definition
Low-Emit Mat'ls, Adhesives/Sealants:
1. SCAQMD Rule 1168
2. GC-36
Term
Greenguard Certification Program is referenced by what?
Definition
EQ 4.5
Low-Emit Mat'ls, Sys Furn/Seating
Term
Req For:
EA Credit 4
Definition
Green Power:
1. 50% electricity from renewable sources
2. min 2 year contract
3. Source defined by:
1. Green-e certified power marketer
2. Green-e accredited utility program
3. Green-e Tradable renewable certificates
4. supply meeting Green-e renewable power def
Term
Req For:
EQ Credit 4.2
Definition
Low-Emit Mat'ls - Paints/Coatings:
1. GS-11
2. GS-03
3.SCAQMD Rule 1113
Term
Req For:
EQ Credit 4.1
Definition
Low-Emit Mat'ls - Adhesives/Sealants:
1. SCAQMD Rule 1168
2. GC-36
Term
Req For:
EQ Credit 2 - for Mechanically Ventilated Spaces
Definition
Increased Ventilation:
1. min 30% increase of outdoor air vent over ASHRAE 62.1-2004
AND
1. meet CIBSE Applications Manual 10-2005 recommendations
OR
2. analytic model to show that 90% of occupied spaces naturally ventilate
Term
Req For:
EQ Credit 1
Definition
Outdoor Air Delivery Monitoring:
1. permanent monitoring systems for vent system
2. mech vent for densely occupied spaces (25 people/1000 s.f. or more) - CO2 Sensor in each densely occupie space
3. other mech vented spaces - measure outdoor airflow and get within 15% of design min outdoor air rate
4. for nat vent spaces - CO2 sensor within each nat vented space
Term
To meet EQ Prereq 2 Option B, how must the smoking room perform?
Definition
1. test differential air pressure
2. measure 15 minutes total -1 measurement every 10 seconds
3. test configured for worst case conditions of transport air to adjacent spaces
Term
Req For:
EQ Credit 3.1
Definition
Construction IAQ Man Plan, During Construction:
1. IAQ Man Plan for Construction and Pre-Occ Phases
2. SMACNA IAQ Guidelines
3. Protect absorptive materials from moisture
4. MERV 8 minimum
5. Replace filtration prior to occupance
6. Coordinate with EQ 3.2 & 5 (single set of final filtration media)
Term
Req For:
EQ Credit 3.2 - Option B
Definition
Construction IAQ Man Plan - Before Occupancy - IAQ Test Procedure:
1. Baseline IAQ Testing according to EPA Compendium
2. if max concentration limits are exceeded, flush out and retest
3. retest same locations each time
Term
Req For:
EQ Credit 7.1
Definition
Thermal Comfort, Compliance:
ASHRAE 55-2004
Term
Req For:
EQ Credit 7.2
Definition
Thermal Comfort, Monitoring:
permanent monitoring system to verify meeting ASHRAE 55-2004 conditions
Term
Req for:
EQ Credit 6.2
Definition
Controllability of Systems, Temp/Vent:
1.min 50% have indiv adjustmnt control
2. shared multi-occupant spaces must share controls
Term
Req For:
EQ Credit 6.1
Definition
Controllability of Systems, Lighting:
1. lighting controls for 90% of occupants
2. shared occupant spaces must share controls
Term
Req For:
EQ Credit 4.4
Definition
Low-Emit Mat'ls, Comp Wood/Lam Adhesives:
1. contain NO ADDED UREA-FORMALEHYDE
2. excludes EQ 4.5 products (sys furn/seating)
Term
Req For:
EQ Credit 4.3
Definition
Low-Emit Mat'ls, Carpet Systems:
1. carpet meets CRI Green Label Plus Testing
2. pad meets same standard
3. adhesive meet EQ 4.1
Term
Req For:
EQ Credit 2 - for Naturally Ventilated Spaces
Definition
Increased Ventilation:
1. Good Practice Guide 237-1998
2. Follow diagraming in CIBSE Application Manual 10-2005
AND ONE OF THESE:
3. MEET CIBSE Applications Manual 10-2005 recommendations
OR
4. analytic model to show nat vent for 90% of occupied spaces
Term
Req For:
EQ Prereq 2 - Option C
Definition
ETS Control for Muli-Unit Residential:
1. minimize uncontrolled pathways for ETS Xfer
2. seal wall, ceiling, floor penetratins
3. seal vertical chases
4. weather strip doors leading to common hallways
Term
Req For:
EQ Credit 3.2 - Option A
Definition
Construction IAQ Man Plan, Before Occupancy - Flush Out Procedure:
After construction and int finishes installed:
1. install new filtration media
2. flush out bldg
3. total air volume 14,000 cu.ft. outdoor air per s/f floor area
4. min 60 deg F
5. max rel hum 60
6. occupy after min 3500 cu ft outdoor air/sf floor area to space
7. vent min .30 cfm/sf ouside air OR design min outside air rate (the greater of the two)
8. min 3 hours prior to occ
9. do this till 14,000 cuft/sf is met
Term
Req For:
EQ Credit 4.5
Definition
Low-Emit Mat'ls, Sys Furn/Seating:
option A - Greengaurd IAQ Certified
option B - EPA ETV Test Protocol, testing in independent air quality testing lab
Term
Exceptions to EQ Credit 8.1 & 8.2?
Definition
yes - Exceptions for areas where tasks would be hindered by the use of daylight will be considered on their merits
Term
Req For:
MR Credit 1.2 & 1.3
Definition
Building Reuse - 40% & 60% Int non-struc comp's:
1. maintain min 40% for 1 pnt
2. maintina min 60% for 2 pnts
3. measure by area of walls, flooring, ceilings
Term
Req For:
MR Credit 1.1
Definition
Tenant Space, Long Term Commitment:
commit to min 10 year stay
Term
Req For:
MR Prereq 1
Definition
Stor/Collect Recyclables:
provide space to collect at min
1. paper
2. plastic
3. glass
4. metals
5. corrugated cardboard
Term
Req For:
EQ Credit 1.4
Definition
optimize Energy Perfomance, Equip & Apps:
use energy star rated equipment that is eligible for the rating:
1. 70% for 1 pnt
2. 90% fo4 2 pnts
Term
Req For:
EA Credit 1.2
Definition
Optimize Energy Performance, Lighting Controls:
1. daylight responsive controls in reg occ'd spaces
2. install within 15 ft of windows and under skylights
Term
Req For:
EA Prereq 3
Definition
CFC Reduction in HVAC&R Equip:
Zero use of CFC-based refrigerants in scope of work
Term
Req For:
MR Credit 2.1 & 2.2
Definition
Construction Waste Management, Divert 50% & 75% from landfill:
1. construction waste management plan
2. quantify mat'l diversion goals
3. recycle or salvage min 50% for 1 pnt
4. recycle or salvage min 75% for 2 pnts
5. calcs can be by weight or volume, but must be consistent
Term
Req For:
SS Credit 1
Definition
Site Selection:
1. LEED certified building - 3 pnts
OR
2. blding that has 2 or more of 12 options - up to 3 points
Term
Req For:
SS Credit 1 - Option A
Definition
Brownfield Redevelopment:
1. ASTM E1903-97 ESA
OR
2. classified as a brownfield by gov't agency and remediation completed
Term
Req For:
SS Credit 1 - Option G
Definition
Site Selection, Water Efficient Irrigation - Reduced Potable Water Consumption:
1. high-efficiency irrigation
OR
2. captured/recylced site water
3. reduce potable water use by 50%
Term
Req For:
SS Credit 1 - Option H
Definition
Site Selection, Water Efficient Irrigation - No Potable Use/No Irrigation:
1. nopotable use - only use of recycled rain or site water
2. excluding watering to establish plants
OR
3. no irrigation that is permanent on site
Term
Req For:
SS Credit 1 - Option I
Definition
Site Selection, Innovative Wastewater Technologies:
1. Reduce Potable Water for Sewage by 50%
2. treat 100% onsite water to tertiary standards
Term
Req For:
SS Credit 1 - Option J
Definition
Site Selection, Water Use Reduction 20%:
1. meets 20% reduction
2. ongoing plan to require compliance in future
Term
Req For:
SS Credit 1 - Option K
Definition
Site Selection, On-Site Renewable Energy:
1. % total bldg energy use supplied by on-site renewable energy systems:
5% for 1/2 pnt, 10% for 1 point
Term
Req For:
SS Credit 1 - Option L
Definition
Other Qunatifiable Env Performance:
1. in place at time of submittal
2. reference requirements from other LEED rating systems
3. up to 3 points total
Term
Req For:
SS Credit 3.1
Definition
Alt Transit - Public Trans Access:
1. 1/2 mile from railway
2. 1/4 mile from 2 or more bus lines
Term
Req For:
SS Credit 3.1
Definition
Alt Transit - Public Transit Access:
1. 1/2 mile from rail
2. 1/4 mile from 2 bus lines
Term
Req For:
SS Credit 2
Definition
DD & CC:
bldg in walkable community with:
1. min density 60,000 sf/acre net (2 story dwntwn dev)
OR
2. bldg is 1/2 mile from res zone/neighborhood with average density of 10/acre net
AND
3. 1/2 mile pedestrian access to minimum of 10 basic services
Term
Req For:
SS Credit 3.2
Definition
Alt Transit - bike tor and hanging rooms:
bike stor and change rooms within 200 yds for 5% tenant occs
Term
Req For:
SS Credit 3.3 - Case A for less than 75% gross blding square footage
Definition
Alt Transit - parking availability:
1. do not exceed zoning regulations for min no of parking spaces
AND
2. priority parking for car-pools for 5% tenant occs
OR
3. no parking provided for tenant occs
Term
Req For: SS Credit 3.3 - Case B for 75% or over gross bldg s/f
Definition
Alt trnsit - parking availability: 1. do not exceed min parking zoning reqs AND 2. priority parking for car-ools for 5% BLDG occs OR 1. no new parking AND 2. priority parking for car-pools for 5% BLDG occs
Term
Req For:
WE Credit 1.1
Definition
Water Use Reduction, 20%:
1. us 20% less water than baseline calc
2. meet EPAct of 1992
Term
Req For:
WE Credit 1.2
Definition
Water Use Reduction, 30%:
1. meet EPAct of 1992 for fixture performance
2. comined, use 30% less water than baseline calc
Term
Req For:
EA Prereq 1
Definition
fundamental cx:
following items are completed by cx team:
1. cx leads process - not directly resp for design or construction
2. document owner's project reqs & basis of design for energy systems
3. incorporate cx reqs into CD's
4. develop CX plan
5. verify that systems meet owners project requirements and intent
6. CX Report
Term
Req For:
EA Prereq 2
Definition
min energy perf:
ASHRAE 990.1-2004 or local energy code (most stringent)
Term
Req For:
SS Credit 1 - Option E
Definition
Site Selection - Heat Island Effect, Roof:
1. roofing meets or exceeds SRI in table for min 75% total roof surface
OR
2. installed green roof for 50% of roof area
OR
3. bldg has combo of green roof and SRI greater than or eq to table referenced
[SEE REFERENCED TABLE & REFERENCED EQUATION]
Term
Req For:
MR Credit 5.2
Definition
Regional Mat's - 10% extract/manuf Regionally:
1. in addition to 5.1
2. 10% of mat'ls/furn for project manufactured AND extracted within 500 miles of project
Term
Req For:
MR Credit 5.1
Definition
Regional Mat'ls - 20% manuf Regionally:
1. minimum 20% combined value of construction/furn manufactured within 500 mile radius
Term
Req For:
MR Credit 4.1 & 4.2
Definition
Recycled Content, 10% & 20% (post = 1/2 pre):
1. incl furniture
2. percentages of total value of mat'ls i project
3. 10% = 1 point
4. 20% = 2 pnts
Term
Req For:
MR Credit 3.3
Definition
Resource Reuse, 30% (furniture):
1. salvaged
2. refurbished
3. used furniture
4. 30% of total furniture budget
Term
Req For:
MR Credit 3.1 & 3.2
Definition
Resource Reuse, 5% or 10%:
1. salvaged
2. refurbished
3. reused mat'ls
4. 5% - 1 pnt
5 10% - 2 pnts
6 NOT INCL FURNITURE!
Term
What systems must be Commissioned?
Definition
min of:
1. HVAC&R systems and controls
2. lighting controls (also daylight)
3. domestic hot water sys's
4. renewable energy systems
Supporting users have an ad free experience!