Term
SSc1A Site Selection: Brownfield Redevelopment |
|
Definition
1/2pt A/ID rehabilitate damaged sites & reduce pressure on undeveloped land ASTM E1903-97 PhaseII environment site assessment EPA Sustainable Redevelopement of Brownsfield Program |
|
|
Term
SSc1B Site Selection: Stormwater Management Rate & Quantity |
|
Definition
1/2pt A/ID limit disruption & pollution of natural water flows Constructed wetland detention ponds porous pavement & permeable surfaces |
|
|
Term
SSc1C Site Selection: Stormwater management treatment |
|
Definition
1/2pt A/ID reduce disruption of natural water flows by increasing site infiltration systems to remove 80% of the avg. annual site area TSS & 40% average annual site area TP |
|
|
Term
SSc1D Site Selection: Heat Island Effect Non Roof |
|
Definition
1/2pt A/ID/AP min. impact on microclimate & habitat 1. reflective paving, shading & or open grid pavement 2. covered parking 3. open grid pavement system only |
|
|
Term
SSc1E Site Selection: Heat Island Effect Roof |
|
Definition
1/2pt A/ID/AP min. impact on microclimate & habitat 1. refelctive roofing mat'l low slope 75% of roof surface area covered w/mat'l SRI greater than 78 2. steep slope SRI greater than 29 3. green roof combo reflective roof & green roof |
|
|
Term
SSc1F Site Selection: Light pollution reduction |
|
Definition
1/2pt A/ID/AP eliminate light leaving site, improve night sky access & reduce impact on nocturnal habits meets or provides lower light levels & uniformity ratios than those rec. by IESNA RP-33-99 more than 1000 initial lamp lumens are shielded |
|
|
Term
SSc1G Site Selection: Water Efficient Irrigation reduced potable water consumption |
|
Definition
1/2pt A/ID reduce potable water use for landscape irrigation 1.high efficency irrigation tech. captured rainwater 2. recycled site water reduced by 50% over conventional means |
|
|
Term
SSc1H Site Selection: Water Efficient Irrigation no potable water use no irrigation |
|
Definition
1/2pt A/ID eliminate potable water for landscape irrigation 1.uses only captured rain or recycled site water (except intial watering to establish plants) 2. does not have permanent landscaping irrigation systems |
|
|
Term
SSc1I Site Selection: Innovative waste water technologies |
|
Definition
1/2pt A/ID reduce wastewater & potable water demand & increase local aquifer recharge Treat 100% of wastewater on site. reduce municipal provided potable water for sewage conveyance by 50% |
|
|
Term
SSc1J Site Selection: Water use Reduction 20% reduction |
|
Definition
1/2pt A/ID reduce burden on municipal water supply & waste water systems & has ongoing to require future occ. to comply EPAct of 1992 |
|
|
Term
SSc1K Site Selection: On site renewable energy |
|
Definition
up to 1pt A/ID reduce fossil fuel energy use 1. supplies at least 5% of the bldg total energy use thru the use of on-site renewable energy systems (1/2pt) 2. 10% of total energy (+1/2pt) |
|
|
Term
SSc1L Site Selection: other quantifiable environmental performance |
|
Definition
1-3pts A/ID reduce environmental impact by restricting site selection & bldg location on site occupy a bldg that has in place quantifiable environ. performance character for which the requirements may be found in other LEED rating systems |
|
|
Term
SSc2 Development, Density & Community Connectivity |
|
Definition
1pt A/AP/E channel development to urban areas w/exist infrastructure, protect greenfields & preserve habitat natural resources 1. development density walkable community 2. community connectivity: bldg w/in 1/2 mile of residential area; ped access to 10 basic services |
|
|
Term
SSc3.1 Alternative Transportation: Public Transportation Access |
|
Definition
1pt A/ID/AP reduce pollution & land development impacts from auto use 1. close to 1/2 mile of commuter rail or subway 2. 1/4 mile of at least 1 stop for at least 2 public or campus bus lines |
|
|
Term
SSc3.2 Alternative Transportation: Bike storage & changing rms |
|
Definition
1pt A/ID/AP reduce pollution & land development impacts from auto use 1.Provide secure bike storagew/in 200yds of bldg 2. w/convenient changing & shower facilities |
|
|
Term
SSc3.3 Alternate Transportation: Parking Availability |
|
Definition
1pt A/ID reduce pollution & land development impacts for auto use 1. Project occupy less 75% of bldg sq ft 5% space for van pools; no parking subsidized for occu. 2. Project occupy 75% 5% spaces for van pools min # of spaces per zoning |
|
|
Term
WEc1.1 Water use reduction: 20% reduction |
|
Definition
1pt E Maximize water efficiency w/in tenanats spaces to reduce the burden on muncipal water supply & wastewater systems 1. meet EPAct 1992 fixture performance req. 2. Use 20% less water than water use baseline |
|
|
Term
WEc1.2 Water use reduction: 30% |
|
Definition
1pt A/ID max. water efficiency w/in tenant spaces to reduce burden on municipal water supply & wastewater systems 1. EPAct of 1992 2. achieve 40% water savings use high efficiency fixtures & composting toilets & non water urinals |
|
|
Term
MRp1 Storage & Collection of Recyclables |
|
Definition
0pts A Facilitate the reduction of waste generated by bldg occupants that is hauled to & disposed of in landfills Provide easy accessible area dedicated to non hazardous mat'l storage & collection paper, corr. cardboard, glass, plastic & meatals |
|
|
Term
WEc1.2 Water Use Reduction: 30% Reduction |
|
Definition
1pt A/ID max water efficiency w/in tenant spaces to reduce burden on municipal water supply & wastewater system 1. EPAct of 1992 2. achieve 40% water savings use high efficiency fixtures & composting toilets & non water urinals |
|
|
Term
|
Definition
0pts E Establish min IAQ performance to enhance indoor air quality contributing to comfort & well being of occupants 1. Naturally ventilated bldgs mech. ventilated bldgs min 10 cubic ft/min/person 2.ASHRAE 62.1-2004 Ventilation for Acceptable Indoor Air Quality |
|
|
Term
EQp2 Environmental Tobacco Smoke (ETS) Control |
|
Definition
0pts prevent or min exposure of occupants indoor surface & systems to ETS 1. Non smoking bldg exterior designated smoking areas 25ft from entry & outdoor intakes 2. designated smoking rms must contain capture & remove ETS 3. Multi-residence bldgs weatherstrip residential unit doors ANSI/ASTM 779-03 |
|
|
Term
EQc1 Outdoor Air Delivery Monitoring |
|
Definition
1pt E provide capacity for ventilation system monitoring to help sustain long term comfort 1. install permanent monitoring & alarm systems 2. monitor CO2 in mech. vented densely occupied spaces. 25people/1000sq ft.locate device 3-6 ft above floor 3. ASHRAE 62.1-2004 Ventilation for acceptable IAQ |
|
|
Term
EQc2 Increased Ventilation |
|
Definition
1pt E provide additional air ventilation to improve IAQ for improve comfort, well being & productivity 1. mech. ventilated spaces increase breathing zone outdoor air ventilation rates by 30% 2. naturally ventilated space 1998 Carbon Trust Good Practice Guide 237 |
|
|
Term
EQc3.1 Construction IAQ Management Plan: During Construction |
|
Definition
1pt GC prevent & reduce IAQ problems resulting from construction process to sustain comfort 1. meet Ch3 1995 SMACNA IAQ use filtration media w/MERV of 8 at each return air grille 2. ANSI/ASHRAE 52.2-1999 method of testing Gen Vent Air cleaning Devices |
|
|
Term
EQc3.2 Construction IAQ Management Plan: Before Occupancy |
|
Definition
1pt A/E reduce indoor air quality problems resulting from construction process 1.bldg flush-out install new filltration media & flush out bldg supply total air volume. 14000 cu ft outdoor air/sq ft area 2. internal temp at least 60 deg. F 3. conduct baseline IAQ testing USEPA compendium of Method Determination of Air Pollutants |
|
|
Term
EQc4.1 Low-Emitting Mat'ls: Adhesives & sealants |
|
Definition
1pt A/ID reduce quantity of indoor air contaminats that are odorous potentially irritating & harmful 1. use only adhesives,sealants that comply SCAQMD Rule #1168 2. Aerosal adhesives: green seal standard for commerical adhesives GS-36 |
|
|
Term
EQc4.2 Low-emitting mat'l :paints & coatings |
|
Definition
1pt A/ID reduce quantity of indoor air contaminats 1. Arch paints coatings primers on walls must not exceed VOC content limits Green Seal Standard GS-11 Anti-corrosive Green Seal GS-03 2. VOC limits Flats 50g/l non-flats 150g/l 3. clear wood finishes SCAQMD Rule 1113 |
|
|
Term
EQc4.3 Low-Emitting Mat'ls : Carpet Mat'ls |
|
Definition
1pt A/ID reduce the quantity of indoor air contaminates 1. use only Green label Plus Program carpets & cushions 2. Carpet adhesive meets VOC limit 50g/L |
|
|
Term
EQc4.4 Low-emitting mat'l: composite wood & laminate adhesives |
|
Definition
1pt A/ID reduce quantity of indoor air contaminats 1. composite wood & agrifiber products laminating adhesive must not contain any added urea-formaldehyde resins 2. furn & equip not included |
|
|
Term
EQc4.5 Low-Emitting Mat'ls: systems furniture & seating |
|
Definition
1pt A/ID reduce quantity of indoor air contaminents 1.systems furn manufactured w/in 1 yr before occupancy must be Greenguard IAQ cert. 2. tested on USEPA ETV protocol for measuring emissions of VOC |
|
|
Term
EQc5 Indoor Chemical & Pollutant Source Control |
|
Definition
1pt A/AP/ID min. exposure to potentially hazardous particuler bio contaminats & chem pollutants that adversely impact air & water quality 1. Install perm. grates/grilles at high-volume entryways 2. pressure differential 5Pa. 1Pa w/closed doors. Air filtration MERV of 13 |
|
|
Term
EQc6.1 Controllability of systems:Lighting |
|
Definition
1pt A provide high level of thermal ventilation & lighting system control provide controls so 90% of occupants can adjust lighting to suit task & all shared multi occupant spaces |
|
|
Term
EQc6.2 Contollability of systems: Temperature & Ventilation |
|
Definition
1pt A provide high level of thermal ventilation & lighting system control 1.provide controls for 50% bldg occu. to adjust thermal comfort 2.operable windows instead of comfort controls in areas 20ft inside & 10 ft either side of win. 3.ASHRAE 62.1-2004(natural ventilation Para 5.1) |
|
|
Term
EQc7.1 Thermal Comfort:Compliance |
|
Definition
1pt E provide thermally comfortable environ. that supports productivity & well-being of tenant space occu. 1. HVAC & bldg envelope meet ASHRAE Standard 55-2004 thermal comfort conditions for human occup. & sec 6.1.1 2. Incase of naturally vent. spaces provide cal. methodology |
|
|
Term
EQc7.2 Thermal Comfort: Monitoring |
|
Definition
1pt E provide thermally comfortable environ. that supports productivity & well being 1. Develop monitoring system to ensure extended EQc7.1 compliance 2. 2methods for validating performance(a. survey occu. b. Analyze environment variables) |
|
|
Term
EQc8.1 Daylighting & Views: Daylight 75% of spaces |
|
Definition
1pt A/AP/ID provide connection between indoor spaces % outdoors thru intro of daylight & views into regularly occupied areas 1.at least 75% of occ. space min. daylight factor of 2% (exclude direct sunlight penetration) use computer simulation model achieve 25 fc 2. provide daylight redirection & glare control devices. exception when daylight hinders task |
|
|
Term
EQc8.2 Daylighting & Views: Daylight 90% of Spaces |
|
Definition
1pt A/AP/ID provide connection between indoor spaces % outdoors thru intro of daylight & views into regularly occupied areas 1.min 90% of occ. space min. daylight factor of 2% (exclude direct sunlight penetration) use computer simulation model achieve 25 fc 2. provide daylight redirection & glare control devices. exception when daylight hinders task |
|
|
Term
EQc8.3 Daylighting & Views: Views for 90% of Seated Spaces |
|
Definition
1pt A/AP/ID provide connection between indoor spaces % outdoors thru intro of daylight & views into regularly occupied areas 1.provide direct line of sight to outdoors thru vision glazing between 2'6&7'6 above floor 2.75% of private office w/direct line of sight outdoors w/in sight lines drawn from perimeter |
|
|
Term
MRp1 Storage & Collection of recyclables |
|
Definition
0pts A facilitate the reduction of waste generated by bldg occcu. that is hauled to & disposed of in landfills 1. provide easily accessible area dedicated to non hazardous mat'l storage & collection includ. paper corrugated cardboard, glass,plastics & metals 2. provide plan showing ded. area |
|
|
Term
MRc1.1 Tenant Space: Long-term commitment |
|
Definition
1pt Conserve resources, reduce waste extend bldg life reduce waste & reduce environ. impacts as they relate to mat'l manufacturing & transport occupant commits to a location for at least 10 yrs |
|
|
Term
MRc1.2 Building Reuse: Maintain 40% of the Interior nonstructural components |
|
Definition
1pt A/ID Conserve resources, reduce waste extend bldg life retain cultural resources & reduce environ. impacts of tenancy related to mat'l manufacturing & transport maintain 40% exist nonshell non struc components wall, floors, clng |
|
|
Term
MRc1.3 Building Reuse:Maintain 60% of the Interior Nonstructural components |
|
Definition
1pt A/ID Conserve resources, reduce waste extend bldg life retain cultural resources & reduce environ. impacts of tenancy related to mat'l manufacturing & transport maintain at leat 60% nonshell nonstruct |
|
|
Term
MRc2.1 Construction Waste Management:Divert 50% from landfill |
|
Definition
1pt A/ID divert construction, demo & land clearing debris from landfill disposal redirect recyclable recovered resources back to the manufacturing process & redirect reusable mat'l to appropriate sites 1.recycle 50% of nonhazardous debris |
|
|
Term
MRc2.2 Construction Waste Management: Divert 75% from landfill |
|
Definition
1pt A/ID divert construction, demo & land clearing debris from landfill disposal redirect recyclable recovered resources back to the manufacturing process & redirect reusable mat'l to appropriate sites recycle salvage 75% nonhazardous construc. & demo debris |
|
|
Term
|
Definition
1pt A/ID reuse bldg mat'l & products in order to reduce impacts associated w/extraction & processing virgin resources salvage, refurb, reuse 5% all mat'l based on cost exclude furniture & furnishings |
|
|
Term
|
Definition
1pt A/ID reuse bldg mat'l & products in order to reduce demand for virgin mat'l & reduce waste 1. reduce impacts associated w/extraction & processing virgin resources 2.salvage, refurb, reuse 10% all mat'l based on cost exclude furniture & furnishings appliances & equip |
|
|
Term
MRc3.3 Resources Reuse: 30% Furniture & Furnishings |
|
Definition
1pt A/ID reuse bldg mat'l & products in order to reduce demand for virgin mat'l & reduce waste 1. reduce impacts associated w/extraction & processing virgin resources 2.salvage, refurb, reuse 30% all systems furn&furnishings, case pieces, seating filing cabs decorative lght based on cost |
|
|
Term
MRc4.1 Recycled Content: 10% (post-consumer & 1/2 pre-consumer |
|
Definition
1pt A increase demand for bldg products that incorporate recycled content mat'l reducing impacts resulting from extraction & processing virgin mat'l 1. 10% total mat'l cost include furnishings MEP not included 2. FTC Guide for use of Environmental Marketing claims 16 CFR260.7 |
|
|
Term
MRc4.2 Recycled Content: 20% (post-consumer & 1/2 pre-consumer) |
|
Definition
1pt A increase demand for bldg products that incorporate recycled content mat'l reducing impacts resulting from extraction & processing virgin mat'l 1. 20% total mat'l cost include furnishings MEP not included 2. FTC Guide for use of Environmental Marketing claims 16 CFR260.7 |
|
|
Term
MRc5.1 Regional Mat'ls: 20% Manufactured regionally |
|
Definition
1pt A/ID increase demand for bldg mat'ls & products that are extracted & manufact. w/in region there by supporting the regional economy & reducing the environ. impact from transportation 20% all construction and furniture mat'l w/in 500miles of project site |
|
|
Term
MRc5.2 Regional Material: 10% Extracted & Manufactured Regionally |
|
Definition
1pt A/ID increase demand for bldg mat'ls & products that are extracted & manufact. w/in region there by supporting the regional economy & reducing the environ. impact from transportation 10% all construction and furniture mat'l extracted harvested or recovered w/in 500miles of project site |
|
|
Term
MRc6 Rapidly Renewable Materials |
|
Definition
1pt A/ID reduce use & depletion of finite raw mat'l & long-cycle renewable mat'l by replacing them w/rapidly renewable mat'l 1. 5% total cost from plants that are typically harvested w/in 10 yrs or shorter cycle 2. Bamboo, wool cpt, strawboard, cotton batt insul |
|
|
Term
|
Definition
1pt A/ID encourage environ. responsible forest management 1. new wood based products & mat'ls use min 50% certified by Forest Stewardship Councils Principles & Criteria 2. COC (chain of custody) document |
|
|
Term
EAp1 Fundamental Commissioning |
|
Definition
0pts CxA verify projects energy related systems are installed callibrated & performs as intended 1.Designate commissioning authority to lead review oversee commissioning process 2. HVAC systems & controls lighting & daylight systems domestic hot water system renewable energy systems |
|
|
Term
EAp2 Minimum Energy Performance |
|
Definition
0pts A/E establish min level of energy efficiency 1.comply w/ANSI ASHRAE IESNA Standard 90.1-2004 or local energy code 2. Design systems to max performance |
|
|
Term
EAp3 CFC Reduction in HVAC & R Equipment |
|
Definition
0pts E reduce ozone depletion No use CFC based refrigerants |
|
|
Term
EAc1.1 Optimize Energy Performance: Lighting Power |
|
Definition
1-3pts E conserve energy beyond the prerequisite standard to reduce environmental impacts associate w/excess use 1. Reduce lighting power density 15%below 1pt. 25% below 2pts. 35% below 3pts. 2. ANSI/ASHRAE/IESNA standard 90.1-2004 |
|
|
Term
EAc1.2 Optimize Energy Performance: Lighting Controls |
|
Definition
1pts E conserve energy beyond the prerequisite standard to reduce environmental impacts associate w/excess use 1.Install daylight responsive controls w/in 15ft of windows & under skylights 2.Design lighting controls to max energy performance |
|
|
Term
EAc1.3 Optimize Energy Performance:HVAC |
|
Definition
1-2pts A/E conserve energy beyond the prerequisite standard to reduce environmental impacts associate w/excess use 1. Equip efficiency & appropriate zoning HVAC energy performance 15-30% savings 2. seperate zone & control measures |
|
|
Term
EAc1.4 Optimize Energy Performance: Equipment & Appliances |
|
Definition
1-2pts A/E conserve energy beyond the prerequisite standard to reduce environmental impacts associate w/excess use 1. 70%eligible equip & appliance Energy Star(1pt) 90% Energy Star (2pts) 2. Excludes HVAC, lighting & bldg envelope products |
|
|
Term
EAc2 Ehanced Commissioning |
|
Definition
1pt verify & ensure that space is designated constructed & calibrated to operate as intended Designate independent Commissioning Authority review energy related systems submital |
|
|
Term
EAc3 Energy Use: Measurement & Payment Accountability |
|
Definition
1-2pts E provide ongoing accountability & optimization of energy & water consumption performance over time 1. area less than 75% of total bldg area install sub-metering equip (1pt) 2.negotiate lease where tenant pays energy costs(1pt) 3. area more than 75% install continuous metering equip (2pts) |
|
|
Term
|
Definition
1pt encourage development & use grid source renewable energy technologies on a net zero pollution basis 1.50% elec. from renewable sources 2yr energy contract procured from Green-e certified power marketer 2.default 16k wh/sq ft min |
|
|
Term
IDc1.1-1.4 Innovation in Design |
|
Definition
1-4pts AP provide design team & projects the opportunity to be awarded pts for exceptional performance above requirements set by LEED Green Bldg Rating System & Innovative Performance in green bldg categories not specifically addressed by LEED 1.ID credit title, intent, requirements approach & appropriate proj dwgs |
|
|
Term
IDc2 LEED Accredited Professional |
|
Definition
1pt AP support & encourage the design integration required by a LEED Green Bldg project & streamline the application & certification process |
|
|