Term
|
Definition
written by a group of experts with field knowledge and no reference to a particular geographical area |
|
|
Term
|
Definition
originally published in 2000, consolidation of the UBC, BOCA, SBC published by ICC (International Code Council) |
|
|
Term
|
Definition
|
|
Term
|
Definition
UL label for a tested assembly |
|
|
Term
|
Definition
sample assembly was tested and passed for certain conditions. label must describe what those conditions are |
|
|
Term
|
Definition
test for fire resistance of construction assemblies *evaluates ability to prevent the passage of fire, heat, and hot gases -2 parts of test, test heat transfer through assembly and hose stream test -given ratings in hours |
|
|
Term
|
Definition
rates door assemblies for passage of heat, flame, and gases, hose stream test similiar to UL10B, UL10C |
|
|
Term
|
Definition
window & glass block assemblies |
|
|
Term
|
Definition
-whether the material is flammable, and if so, if it burns or if it supports combustion -degree of flammability (how fast) -how much smoke and toxic gas it produces |
|
|
Term
|
Definition
steiner tunnel test - tests flame spread classifies materials by flame spread Class A (I), B (II), C (III) A is the mostfire resistant |
|
|
Term
|
Definition
measures amount of smoke given off same test as NFPA 258 smoke density of less than 450 typical req. |
|
|
Term
|
Definition
tests flooring for flame spread same test as NFPA 253 watts per sq meter, higher the number, the more resistant the material Class I - hospitals, nursing homes, detention facilities Class II - other spaces
IBC allows Class II materials in sprinklered buildings where Class I may otherwise be req |
|
|
Term
|
Definition
carpet flammability tests ignition ability methanine pill test required for all carpet sold in US |
|
|
Term
|
Definition
room corner test sometimes required as an alternate to the tunnel test to simulate real world conditions tests wall,floor, ceiling spread |
|
|
Term
|
Definition
evaluates materials other than textiles mounted to wall or ceiling, tests for their contributions to fire spread, heat, smoke |
|
|
Term
|
Definition
flammability of window treatments 2 types of tests based on weight of fabrics pass or fail |
|
|
Term
code requirements for fire protection, 2 broad categories |
|
Definition
resistance of materials and assemblies
surface burning characteristics of finish materials |
|
|
Term
|
Definition
wall assembly with rating of one hour tenant separation, corridor walls one hour rated, sometimes stops at rated ceiling |
|
|
Term
|
Definition
vertical or horizontal seperate occupancies, enclose vertical exit enclosures always continuous from floor to deck |
|
|
Term
|
Definition
continuous vertical or horizontal membrane with a minimum fires resistance rating of 1 hour passive form of smoke control |
|
|