Term
HPCI
Describe the function of HPCI. |
|
Definition
-HPCI is designed to be at rated flow within 25 seconds of an initiation signal. -The accident analyses assume that HPCI is at rated flow within 45 seconds of an initiation signal. |
|
|
Term
HPCI
Describe the HPCI initiation signals. |
|
Definition
-Rx low low water level: -47". -High drywell pressure: 1.84psig. |
|
|
Term
HPCI
Describe what happens on HPCI auto initiation. |
|
Definition
-Aux oil pump starts. -Gland seal blower starts. -Steam isolation outboard valve (MO-2035) opens. -Steam supply to turbine valve (MO-2036) opens. -Pump supply to Rx valves (MO-2067/2068) open. -Minimum flow valve (CV-2065) opens allowing minimum flow to TORUS. -Hydraulic stop (HO-7) and governor valve (HO-8 from ramp generator) open. -Test return to CST valve (MO-2071) shuts. -Test return to CST drag valve (CV-3503) shuts. -Steam trap isolations to main condenser (CV-2046A/2046B) shut. -Condensate discharge to CRW valves (CV-2398A/2398B) shut aligning flow to suction of booster pump. |
|
|
Term
HPCI Describe the HPCI suction auto transfer. |
|
Definition
-If CSTs reach 2'8" automatically opens TORUS suction valves (MO-2061/2062) and when full open shut CST suction valve (MO-2063). -Same thing happens if TORUS level reaches +2". |
|
|
Term
HPCI
Describe the HPCI trips (group IV). |
|
Definition
-Low steam pressure: 100psig. -High steam line area temp: 187.5F. -High steam flow: 300,000lbm/hr for 4 seconds. |
|
|
Term
HPCI
Describe the HPCI trips. |
|
Definition
-On a trip it will close the turbine stop valve (HO-7). -Turbine overspeed: 5000rpm (resets after 4 to 6 seconds). -High Rx water level: +48" (resets at -47"). -Turbine high exhaust pressure: 150psig (resets at 90psig). -Pump suction low pressure: 16.5" Hg (resets at 10" Hg). -Manual push button on C-03. |
|
|
Term
HPCI
Describe the turbine minimum speed and why. |
|
Definition
-Turbine kept above 2150rpm. -Done to prevent water hammer from check valve cycling. |
|
|
Term
HPCI
Describe the test return valve (MO-2071 & CV-3503) interlocks. |
|
Definition
If either TORUS suction valve (MO-2061/2062 is open then the test return valves will shut. |
|
|
Term
HPCI
Describe the operation of the aux oil pump. |
|
Definition
-Will start on initiation (-47"/1.84#). -Will trip when oil pressure reaches 90psig. -Then gear driven pump takes over. -Will restart when oil pressure reaches 35psig. |
|
|
Term
HPCI
Describe limitations in using HPCI for level/pressure control. |
|
Definition
Cannot do pressure/level control with suction aligned to the TORUS. |
|
|
Term
HPCI
Describe the affect on HPCI valves on a loss of Div II 125Vdc. |
|
Definition
All HPCI suction valves open with a loss of Div II 125Vdc. |
|
|
Term
HPCI
Describe the power supplies to HPCI. |
|
Definition
-HPCI power: Div II 250Vdc #16 battery. -250Vdc = MCC-312. -125Vdc = D-100/21. -Only AC power is inboard steam isolation valve (MO-2034) from MCC-143A. -Instrumentation = Y-20/80. |
|
|