Term
Any new appliance/installation which is not commissioned. |
|
Definition
Must be disconnected from the gas supply and sealed using an appropriate fitting |
|
|
Term
Immediately Dangerous (ID) |
|
Definition
Three main situations are. 1.Gas Escapes 2.Spillage from a flued appliance 3.Incomplete Combustion from a flueless appliance |
|
|
Term
|
Definition
Appliance/installation,which if operated or left connected to gas supply MAY IN FUTURE CREATE A DANGER |
|
|
Term
|
Definition
Cover all EXISTING installations and appliances using 1st 2nd or 3rd family of gases,both domestic and non domestic premises |
|
|
Term
Visual Risk assessment NO Interruption to supply |
|
Definition
1.Location (suitable for appliances) 2.Stabilty and Security (Examine appliance) 3.Ventillation(check if there is adequate ventilation for appliance to operate safely 4.Flueing-examine any open flued or room sealed appliance to ensure the flue system is intact 5.Signs of distress-Check for signs of heat damage ,spillage |
|
|