Accuracy
Definition
The number of correct test results divided by the total number of testes defines:
Term
Negative test results divided by the total number of negative tests
Definition
Specificity is defined as the number of correct:
Term
Hydrophone
Definition
Which testing device measures acoustic output?
Term
Routine evaluation of the transducer and ultrasound system
Definition
What most accurately describes quality assurance?
Term
Transducer characteristics
Definition
The beam profiler is a testing device that measures:
Term
Biannually
Definition
Preventive maintenance service is generally completed:
Term
Registration accuracy
Definition
The ability to place reflections in proper positions no matter the imaging orientation describes:
Term
A quality assurance program
Definition
Routine periodic evaluation of t the ultrasound system illustrates:
Term
Phantom
Definition
A testing device with characteristics of specific soft tissue is termed a:
Term
After each patient
Definition
Cleaning of the transducer should be performed:
Term
Compression
Definition
The American Institute o Ultrasound in Medicine (AIUM) 100 test objects cannot evaluate:
Term
Hospital and output clinic accreditation
Definition
Record keeping of each ultrasound unit is necessary for:
Term
90%
Definition
What is the test accuracy if 10 of 100 examinations are misdiagnosed?
Term
Positive test results divided by the total number of tests
Definition
The positive value is determined byt the number of correct:
Term
System sensitivity
Definition
The AIUM 100 test object evaluates?
Term
Hydrophone
Definition
Which testing device employs a small transducer element?
Term
Image quality
Definition
Quality assurance programs provide assessment of:
Term
Tissue-equivalent phantom
Definition
Which testing device will a quality assurance program most likely use?
Term
The power of the sound beam
Definition
A force-balance system measures
Term
Pulse repetition period (PRP)
Definition
The hydrophone measures:
Term
Sensitivity
Definition
The number of correct positive test results divided by the total number of positive test yields the:
Term
Beam profiler
Definition
Which testing device plots reflection amplitudes received by the transducer?
Term
Preventive maintenance services
Definition
Which of the following evaluates the operations of the ultrasound system?
Term
Acoustic output testing
Definition
Which of the following evaluates the safety and biological effects of ultrasound imaging?
Term
Predict normal findings
Definition
Negative predictive value is the ability of a diagnostic test to:
Term
Pressure of the sound beam
Definition
The output of the hydrophone indicates the:
Term
Preventive maintenance service
Definition
Periodic internal cleaning and overall evaluation of th ultrasound system describes:
Term
Hydrophone
Definition
Testing device that measures the pulse repetition period.
Term
Integrity of the transducers and connections
Definition
Each sonographer should routinely evaluate the:
Term
Direction of flow
Definition
Tissue-mimicking phantoms are unable to evaluate:
Term
Pulser and transducer
Definition
Acoustic output testing considers only the:
Term
Lateral resolution
Definition
The width of the sound beam determines the:
Term
Image consistency
Definition
Developed of a quality assurance program ensures:
Term
20%
Definition
100 abdominal aorta exams were performed over a 6-month period correctly diagnosed 20 of 25 positive examinations and all negative examinations..

The positive predictive value of this study is:
Term
80%
Definition
100 abdominal aorta exams were performed over a 6-month period correctly diagnosed 20 of 25 positive examinations and all negative examinations..

The sensitivity of this study is:
Term
95%
Definition
100 abdominal aorta exams were performed over a 6-month period correctly diagnosed 20 of 25 positive examinations and all negative examinations..

The overall accuracy of this study is:
Term
75%
Definition
100 abdominal aorta exams were performed over a 6-month period correctly diagnosed 20 of 25 positive examinations and all negative examinations..

The negative predictive value of this study is:
Term
Weekly
Definition
Fan filters on the ultrasound system should be cleaned:
Term
Near the transducer face
Definition
The dead zone is located:
Term
Sensitivity
Definition
The ability of a diagnostic technique to identify the presence of genuine disease is termed:
Term
Hydrphone
Definition
Use of a piezoeletric membrane is found in a:
Term
Doppler phantom
Definition
testing device that simulates clinical conditions:
Term
Specificity
Definition
The ability to identify correctly the absence of disease is termed:
Term
Biomedical engineer
Definition
Preventative maintenance service is usually performed by a:
Term
Quality of being near the true value
Definition
Accuracy of a diagnostic test is most accurately defined as the:
Term
Blood flow
Definition
Tissue-mimicking phantoms cannot evaluate:
Term
Transducer characteristics
Definition
A device that plots three-dimensional reflection amplitudes received by the transducer evaluates
Term
Moving string phantom
Definition
Testing device that can simulate pulsatile or retrograde flow:
Term
Hydrophone
Definition
The relationship between the amount of acoustic pressure and the voltage produced is evaluated by the:
Term
90%
Definition
What is the accuracy of a diagnostic test if 2 examinations of 20 are misdiagnosed?