Term

18-1. The device that controls the volume of air and its distribution in an HVAC system is called

a. convector

b. grille

c. register

d. duct

Definition
c. register
Term

18-2. What type of system would be best for an open office plan so the heating and cooling for each workstation could be individually controlled?

a. all-air

b. all-water

c. radiant panel

d. air-water

Definition
a. all-air
Term

18-3. What is NOT allowed in a return-air plenum?

a. fire dampers

b. electrical cable

c. water supply pipes

d. wood blocking

Definition
d. wood blocking
Term

18-4. In working with an electrical engineer on a project, what information would the desginer most likely put on the interior design power plan?

a. switch locations

b. dedicated outlets

c. conduit sizing

d. speaker locations

Definition
b. dedicated outlets
Term

18-5. What type of sprinkler head should be used for a decorative, open-grid, wood-slat ceiling suspended from the structural floor above?

a. upright

b. pendent

c. sidewall

d. recessed

Definition
a. upright
Term

18-6. What is the name of the flat part of the stair that walked on?

a. riser

b. tread

c. nosing

d. run

Definition
b. tread
Term

18-7. In specifying new window coverings and track to replace building standard window coverings, what coordination is LEAST important for the interior designer to undertake?

a. asking the electrical engineer if the new light reflectance is detrimental

b. verifying that the building owner does not care about the change in the building's exterior appearance

c. determining if the mechanical engineer objects to the replacement plans

d. checking with the architect to see that the new coverings do not adversely affect the heating of the glass

Definition
a. asking the electrical engineer if the new light reflectance is detrimental
Term

18-9. What would be the best combination of dimensions for a stair serving a sleeping loft in a condominium where space was at a premium and the floor-to floor dimension was 9'-4"?

a. 7"riser, 10" tread

b. 7"riser, 11" tread

c. 8" riser, 10" tread

d. 8" riser, 11" tread

Definition
a. 7"riser, 10" tread
Term

18-10. What would NOT be allowed in an access floor with removable panels?

a. computer cable

b. plumbing

c. HVAC

d. electrical conduit

Definition
b. plumbing
Term

18-11. In a plenum, how can a fire be prevented from spreading horizontally?

a. install sprinkler systems

b. use fire-rated dividers

c. use fiberglass material

d. install fire dampers

Definition
b. use fire-rated dividers
Term

18-12.  A client has requested that special security protection be provided for critical paper files containing corporate trade secrets, but at t reasonable cost.  In designing the file room, the interior designer should suggest.

a. card readers at the doors leading to the file room

b. photoelectric beams within the room

c. magnetic contacts on all doors leading to the file room

d. electronic sheilding of the file room

Definition
a. card readers at the doors leading to the file room
Term

18-13. In a nonresidential building, how many stair risers equals a flight?

a. 1

b. 2

c. 3

d. 12

Definition
b. 2
Term

18-14. What term is used to denote the member supporting the treads in a wood stairway?

a. carriage

b. header

c. saddle

d. stringer

Definition
a. carriage
Term

18-15. In designing a new space, the interior designer can influence life safety the most by coordinating with consultants concerning

a. compartmentation

b. fire detection

c. smoke control

d. sprinklers

 

Definition
d. sprinklers
Term

18-16. If all of the following are present, what must be modified to achieve acoustic separation in a perimeter office?

a. acoustical tiles

b. gypsum wallboard

c. convector

d. batt insulation

Definition
c. convector