Electronic COMBUSTION Gas Analyser |
|
|
Term
|
Definition
Can measure O2 and CO Can calculate CO2 Can measure ambient temp And Flue Gas Temp |
|
|
Term
|
Definition
Check O2 level-s/b 20.9%+- 0/1% (20.8-21% OK) CO level s/b ZERO |
|
|
Term
Difference between GROSS and NET |
|
Definition
GROSS:Is based on Max c.v the gas will produce. NET: Is based on GROSS-The latent heat of condensation for natural gas |
|
|
Term
|
Definition
1.Bent probe with holes used for flueless gas fires. 2.Straight probe with holes used for testing cooker grills |
|
|
Term
R.S.A without an internal test point |
|
Definition
Position the Analyser,in the flue outlet duct outside |
|
|
Term
ECGA Open flued appliances |
|
Definition
Position the probe up through the D.D. In about 200mm |
|
|
Term
|
Definition
For commissioning of c.h boilers and servicing if A band condensing boilers |
|
|
Term
|
Definition
ECGA Moving away from electrolytic sensors to IR sensors. (Reduces maintenance and cost of calibration ) |
|
|
Term
ECGA. Testing of other fuels |
|
Definition
Change the fuel when testing combustion of other fuels Or CO2 readings will be incorrect. |
|
|
Term
Taper Plug Valve Construction |
|
Definition
Consists of a tapered brass or aluminium barrel. |
|
|
Term
Taper Plug Valve Construction 2 |
|
Definition
2.Barrel is inserted into the body of the valve.Held in place by a spring or nut. |
|
|
Term
Taper Plug Valve Operation |
|
Definition
Lubricated by graphite grease,this ensures ease of operation and remains gas tight |
|
|
Term
Taper Plug Valve operation 2 |
|
Definition
Valve is operated manually by means of handle/knob. Commonly used to isolate appliances or installations. |
|
|
Term
Open Flued Appliance COMPARTMENT Venting to OUTSIDE |
|
Definition
High Level 5cm2/kW Low Level 10cm2/kW
In Room-NIL [image] |
|
|
Term
Open Flued Appliance COMPARTMENT Venting to ROOM |
|
Definition
High Level 10cm2/kW Low Level 20cm2/kW Room Vent-Max Heat Input(net)-7kW x 5cm2[image] |
|
|
Term
|
Definition
Max Heat Input(Net)-7kW x 5cm2 |
|
|
Term
Room Sealed Appliance COMPARTMENT Venting to OUTSIDE |
|
Definition
High Level-5cm2/kW Low Level -5cm2/kW In Room-NIL[image] |
|
|
Term
Room Sealed Appliance COMPARTMENT Venting to ROOM |
|
Definition
High Level 10cm2/kW Low Level 10cm2/kW In Room-NIL[image] |
|
|
Term
Room Sealed Appliance Room |
|
Definition
|
|
Term
Ventilation NET Heat Input Value |
|
Definition
Divide the gross value by 1.1 |
|
|
Term
|
Definition
Air that can leak into buildings through windows,doors,floorboards walls etc |
|
|
Term
|
Definition
No allowance can be made for adventitious ventilation |
|
|
Term
|
Definition
Specially designed to prevent spread of fire. Normally an insert with metal framework,open latticework of heat sensitive material |
|
|
Term
Design width of Vent grill |
|
Definition
Permits entry of a ball of 5mm diameter but prevents entry of a ball of 10mm diameter |
|
|
Term
Installation of a vent in internal wall or door |
|
Definition
No greater than 450mm from floor level |
|
|
Term
Fluess appliance ventilation requirements |
|
Definition
Consult M.Is or table in BS5440-2 Any air vent required must be direct to outside |
|
|
Term
Ventilation for flueless space heater in a ROOM |
|
Definition
1.Convert kW to Watts by x the net heat input by 1000 2.Then DIVIDE by the volume of the room Answer must be 45W/m3 or less |
|
|
Term
Gas Fired Appliances Minimum Flue Diameter is |
|
Definition
|
|