ABR: ANSD and Retrocochlear Pathology
Physiologic Measures 2
10
Audiology
Graduate
10/24/2018

Additional Audiology Flashcards

 


 

Cards

Term
When was ANSD first published about?
Definition
1996
Term
What are three methods for obtaining an ABR for screening for retrocochlear pathology?
Definition
-stacked ABR
-Standard using click
-Tone pip ABR
Term
Stacked ABR:
-Who invented this?
-Very ___ intensity
-How often is it used clinically?
[image]
Definition
-Manny Don
-high
-rarely used
Term
Stacked ABR:
-___ available in most clinical equipment
-Based on measurement of wave V amplitudes which have ___ variability and ___ repeatability
Definition
Not; high; low
Term
Which one has the acoustic tumor on this standard ABR with click?
[image]
Definition
The top one
Term
ABR Tone Pip:
-Developed by ___ et al
-Tone pip with ___ rise/fall times (twice that of standard rise fall 2-0-2 Blackman ramping)
-Longer rise/fall times allows improved ___ specificity
-___-shaped
-Frequencies ____, ___, and ____ Hz
Definition
Kochanek; long; frequency; Gaussian; 1000, 2000, and 4000
Term

Standard ABR and ABR TP:

-Both Standard ABR and ABR TP have ___ sensitivity (higher for TP)

-___ specificity (higher for ABR STD)

-Relative high positive ___ value

-___ of instrumentation

-___ test time (__ minutes)

-Must be visually interpreted by ___ 

 

 

Definition
high; Good; predictive; Availability; Short; 10; audiologist
Term
Subject Characteristics for Retrocochlear Pathology:
-No ___ hearing loss
-Sensorineural hearing loss less than ___ dB HL
-No ___ sloping audiograms
-No interaural audiometric differences greater than ___ dB from
500-8000 Hz
Definition
conductive; 50; steeply; 10
Term
When was ANSD first published about?
Definition
1996
Term
Stacked ABR:
-Very ___ sensitivity
-___ specificity
-___ test time (__-__ minutes)
Definition
high; Low; Long; 40-60