Shared Flashcard Set

Details

6 - Subpart O
Testing Freq, Leakage Allowances & Recordkeeping (135-151)
18
Other
Professional
09/16/2017

Additional Other Flashcards

 


 

Cards

Term
Surface Safety Valve (SSV)
Definition

- ZERO Leakage Allowed

-Tested Monthly, Not to Exceed 6 Weeks

Term
Boarding Shutdown Valve (BSDV)
Definition

-ZERO Leakage Allowed

-Tested Monthly, Not to Exceed 6 Weeks

Term
Flow Safety Valve (FSV)
Definition
No More Than: 15 scf of Gas or 400cc of Liquid Per Minute & tested Monthly, Not to Exceed 6 Weeks
Term
Pneumatic ESD
Definition

-Testing by alternating ESD stations monthly not to exceed     6 weeks (42 days).

Term
Fusible Plug (TSE)
Definition
Recommend that ____ removed quarterly
Term
Electronic ESD
Definition

- Tested Every 3 Months (not to exceed 120 days)

Term
Underwater Safety Valve (USV)
Definition

- Testing is every 3 Months, not to exceed 120 days   

Term
1. SCSSV
2. SCSSV (Not in a Landing Nipple)
3. Tubing Plugs & Injection Valves
Definition
Semi-Annually (Every 6 Months) Testing
Term
1. SSCSV (In a Landing Nipple)
2. TSH (In the Process)
Definition
Annual Testing
Term
Flame, Spark, and Detonation Arrestors
Definition
Visually Inspected Annually,
Term
Firewater Pumps must be run and tested _____________.
Definition
Term
5 & 200
Definition
SDV or BDV must not leak more than _______ feet³ per minute of gas or _______ cm³ per minute of liquid?
Term

Platform Pollution Check

 

Definition
Observe every day and document results.
Term
1. SSCSV (In a Landing Nipple)
2. TSH (In the Process)
Definition
Annual Testing
Term
Flame, Spark, and Detonation Arrestors
Definition
Visually Inspected Annually
Term
All records of Subsurface and Surface Safety Devices testing and results shall be maintained for period of ________ years.
Definition
Term
All records (except Cranes) are required for a period of _______ years.
Definition
Term
Cranes Inspections
Definition
Supporting users have an ad free experience!