What percent of all fires in sprinklered buildings are extinguished with sprinkler systems? |
|
Definition
|
|
Term
The most common sprinkler system is the? |
|
Definition
|
|
Term
Where are DRY pipe systems found? |
|
Definition
In areas subject to freezing |
|
|
Term
What are DRY pipe systems normally pressurized to? |
|
Definition
|
|
Term
What kind of sprinkler system is activated by heat dector and smoke dectors and have fusible links? |
|
Definition
|
|
Term
What kind of systems are used to protect high hazard areas such as a aircraft hanger? |
|
Definition
|
|
Term
What is different about the sprinklers on a Deluge system? |
|
Definition
|
|
Term
A COMBINED System is normally found in buildings from 19___ to ______? |
|
Definition
|
|
Term
Buildings with a COMBINED system are over _________ ft. in height. |
|
Definition
|
|
Term
When the water for a given sprinkler head is delivered from two or more risers. This is a ________ system. |
|
Definition
|
|
Term
A simple inexpensive protection system for light hazard occupancies were not over 3 or 4 sprinklers are likely to operate. |
|
Definition
|
|
Term
The JUNIOR System is fed through a domestic water supply via a _____________ and electric water flow alarm. |
|
Definition
|
|
Term
A JUNIOR System will discharge __________ as much water as a standard 1/2" sprinkler head. |
|
Definition
|
|
Term
Where will you find a JUNIOR System? |
|
Definition
Buildings 3 stories or less, or uses 20 heads or less |
|
|
Term
What is the Dorothy Maw Ordinance? |
|
Definition
Requires all Pre 1943 multiple unit residential buildings, 3 or more stories in heaight, to meet certain fire saftey requirements. |
|
|
Term
Dorothy May Ordinance requires that sprinkler heads be placed no less then ________ ft. inside a door and no FURTHER than ________ feet from the door. |
|
Definition
|
|
Term
To meet the Dorothy Mae ordinance sprinklers must be residential quick response typw and be rated for the lowest operating temp availiable which is ________? |
|
Definition
|
|
Term
All buildings affected by the Dorothy Mae Ordinance will be required to be compliant with the ___________? |
|
Definition
|
|
Term
What are the 3 types of control valves? |
|
Definition
|
|
Term
Purpose is to shut down the complete system or isolate parts of the system for repairs or testing? |
|
Definition
|
|
Term
All control valves SHOULD be open at all times. To do so business owners should secure them with a ___________? |
|
Definition
|
|
Term
Post Indicator Valves are normally painted _________ and are located above ground outside of the building at a distance of about ___________ ft. |
|
Definition
|
|
Term
Where are OS&Y and Gate Valves usually located? |
|
Definition
inside the building; near the standpipe or riser |
|
|
Term
Sprinkler heads extended down from piping? |
|
Definition
|
|
Term
Spinkler heads that sit on top of piping? |
|
Definition
|
|
Term
Sprinkler heads that extend from the side, used when piping runs along a wall. |
|
Definition
|
|
Term
Sprinklers that are recessed into the ceiling? |
|
Definition
|
|
Term
Some flushed sprinklers have a ________ deg disc which covers the head, then drops away exposing the ________ deg. sprinkler head. |
|
Definition
|
|
Term
A sprinkler for a domestic water supply that are "fast response" heads. |
|
Definition
|
|
Term
Junior System Heads are identified by a ____________? |
|
Definition
"Pintle"----- What the heck is a Pintle ??? |
|
|
Term
How many different kinds of release mechanisms are there? |
|
Definition
|
|
Term
How many different kinds of spinkler heads are there? |
|
Definition
|
|
Term
What is the sprinkler head temperatures for the various sprinkler heads? |
|
Definition
(Ugly) Uncolored 165 (White) White 212 (Boys) Blue 286 (Rarely) Red 360 (Go) Green 400 (Out) Orange 500 |
|
|
Term
The effective discharge range for an effective sprinkler head is ____ ft. out and ________ ft. below the head. |
|
Definition
|
|
Term
What sprinkler informaiton is obtained from the solder links of a sprinkler head? |
|
Definition
- Temperature
- Manufacturer
- Style
- When it was manufactured
|
|
|
Term
What are the 6 components to the sprinkler heads? |
|
Definition
- Deflector
- Frame
- Orifice
- Cap
- Threads
- Inside Diameter
|
|
|
Term
What referes to the accumulation of dirt and slow operation of sprinkler heads? |
|
Definition
|
|
Term
How do you prevent "loading" on sprinkler heads? |
|
Definition
- Vacuum with a soft bristle
- compressed air
- exchange sprinkler head
|
|
|
Term
If it is obvious that a fire is in progress and a number of heads have opened, pump pressure should be increased to ______ psi? |
|
Definition
|
|
Term
What are 6 different tools that we can use to shut off an activated or damaged sprinkler head? |
|
Definition
- Shultz shut-off tool
- Petersen wedge
- Redwood plugs
- Globe Valve
- 2 1/2" hose to divert flow of water
- Sprinkler wrench
|
|
|
Term
Company inspections/pre-fire are set by Cheif Regulation 4 every _______ yrs. |
|
Definition
|
|
Term
Company inspections should make sure there are no obstructions _______ from head and that there is access to aisles with a minimum width of ________. |
|
Definition
|
|
Term
How many spare heads are required for specific systems? |
|
Definition
- 0-300 = 6 Spares
- 301-1000 = 12 Spares
- 1000+ = 24 Spares
|
|
|
Term
If no fire is showing companies should supply ________ psi to the inlet. |
|
Definition
|
|