Term
What is the primary goal of effective ventilation operations? |
|
Definition
The reduction or removal of smoke, heat and fire gases from a structure or enclosed area in a timely manner. |
|
|
Term
How do plans for ventilation operations begin? |
|
Definition
by the identification of the direction contaminants must travel to exit the area. (Horizontal or Vertical) |
|
|
Term
What are the 2 directions that contaminants (smoke, etc.) move? |
|
Definition
|
|
Term
What are the 2 basic methods utilized to pressurize a contaminated area? |
|
Definition
1. Natural ventilation 2. Mechanical positive pressure ventilation. |
|
|
Term
What happens to products of combustion as a fire burns within a confined building? |
|
Definition
It fills all available space within a building. |
|
|
Term
What factors is effective ventilation dependent on? |
|
Definition
1. Proximity of the ventilation opening to contaminates to be removed.
2. Ability of contaminates to travel unobstructed to the ventilation opening.
3. Number and size of ventilation openings.
*4. Direction of Wind
*5. Humidity
6. Temperature differential between the interior and exterior of a building. |
|
|
Term
What are your options when utilizing portable blowers? pg 5 LP 527 |
|
Definition
1. Exit through pre-selected and/or controlled openings. 2 Allow the use of ventilation openings that are remote from contaminates. 3. Overcome interior - exterior temperature differentials. 4. Move contaminate through areas or openings not normally utilized by natural ventilation. 5. Reduce time necessary to ventilate a building compared to natural ventilation operations. |
|
|
Term
What are the current methods that are utilized to provide pressurized ventilation with portable blowers? |
|
Definition
1. Negative pressure ventilation 2. Positive pressure ventilation |
|
|
Term
Where is the blower placed when utilizing the Negative pressure ventilation method? |
|
Definition
the building to exhaust the contaminants |
|
|
Term
What are the disadvantages of negative pressure ventilation? |
|
Definition
1. Personnel must be exposed to hazardous contaminants to position a blower.
2 Contaminants are drawn through the blower, creating additional equipment cleanup and maintenance.
3. Blowers placed in doorways or hallways can block entry or exit to the building
4. To be effectively positioned, blowers suspended in doorways or windows must utilize straps, ladders, or other accessories.
5. Interior blowers are not efficient in removing contaminants at the top of a room or building. |
|
|
Term
How will air normally travel during pressurized ventilation? |
|
Definition
In the path of least resistance, which is normally a straight line from the fresh air inlet to the blower. |
|
|
Term
Where is the blower placed for Positive Pressure Ventilation? |
|
Definition
|
|
Term
What are the advantages of positive pressure ventilation compared to negative pressure ventilation? |
|
Definition
1. Personnel not exposed to hazardous contaminants
2. Contaminants not drawn through blowers; less equip. cleanup and maint.
3. Doorways, windows and halls stairwells don't need to be blocked by blowers.
4. Exterior blowers take less time and fewer personnel to put into operation.
5. Positive pressure ventilation is about as effective at removing contaminants from a building compared to neg. pressure ventilation.
6. Exterior blowers provide a reduced noise level and remove contaminants from the whole room. |
|
|
Term
To achieve maximum ventilation what must be controlled? |
|
Definition
Air flow between openings |
|
|
Term
The size of the exhaust opening is dependent upon what? |
|
Definition
The location of the heat and smoke, and the prioritization of suppression operations. |
|
|
Term
For best efficiency, what size should the exhaust opening (heat hole, window, door, etc.) be? |
|
Definition
Between 3/4 - 1 3/4 the size of the entrance opening. |
|
|
Term
If an exhaust odor is noticeable inside the building what does this indicate? |
|
Definition
it is an indicator that the exhaust opening is not large enough. |
|
|
Term
Which one of these weather aspects have a significant effect on the operation of blowers?
a) Temperature b) Humidity c) Rain d) Wind |
|
Definition
d) Wind
It can have an adverse effect on positive pressure ventilation, but its effect is dependent on the direction and velocity. |
|
|
Term
How can maximum blower efficiency be obtained? |
|
Definition
by utilizing prevailing wind direction to an advantage (windward to leeward) |
|
|
Term
How effective is positive pressure against wind? |
|
Definition
Positive pressure has proven effective AGAINST winds of up to mph. |
|
|
Term
Personnel not involved in the ventilation operation must not do what? |
|
Definition
reposition blowers OR alter exhaust openings. |
|
|
Term
Optimum placement of blowers is dependent on what two factors? |
|
Definition
1. Size of the entrance opening 2. The CFM (Cubic Feet per Minute) of the blower. |
|
|
Term
What are the two sizes of blowers carried on Department apparatus? |
|
Definition
1. Small blowers (18 inch) 2. Larger blowers (24 inch) |
|
|
Term
What problems may be encountered when tilting blowers at angles more than the manufacturer has specified? |
|
Definition
a lack of lubrication to the crankshaft. |
|
|
Term
What are the benefits of using multiple blowers during a ventilation? |
|
Definition
It can dramatically increase CFM when used in series or provide proper coverage of the opening when used in parallel. |
|
|
Term
How is maximum effectiveness achieved for standard entrance openings? |
|
Definition
by placing two blowers in series (in-line) with each other. |
|
|
Term
Where should the two blowers be positioned? |
|
Definition
1. One is positioned 2 about two feet away from door to ensure ingress/egress of personnel while getting all air into the entrance.
2. The 2nd blower is utilized to cover the entrance opening with pressurized air and it increases the capacity of the first blower by approx. |
|
|
Term
For standard openings, which configuration is effective? |
|
Definition
Multiple blowers in parallel (side-by-side) configuration are less effective than |
|
|