Term
APU Limits
Max Altitude for Start
Max Tailwind for Start
Max Rotor speed
EGT: Start
Continuous
Starter Limits
Between three Consecutive Attempts
Between 2 series of 3 consecutive attempts |
|
Definition
APU Limits
30 000ft
30kt
108% (Shuts off at 104%)
884°C
680°C
Starter Limits
1 min off
30 mins Off |
|
|
Term
Power Plant
N1
N2
ITT: Start
Takeoff
Continuous
Oil Pressure: >88% N2
=<88% N2
Oil Temp Vibration LP: HP: |
|
Definition
Power Plant
100%
102.5%
800°C
948°C(5mins Max)
901°C
34PSI -> 95 - 110psi (can be exceeded if oil temp>21°C engine must idle to get >95psi)
50psi ->95 - 110psi 21 - 126°C
1.8IPS 1.1IPS |
|
|
Term
|
Definition
After start, the engines must run at idle or taxi thrust for at least 4 minutes for cold engines or 2 minutes for warm engines. Before takeoff, to increase N2 above 83% the engine oil temperature must be at 40°C minimum. In lieu of this limit, it is acceptable to either: - - run the engine for at least 8 minutes in idle or taxi thrust and check if the temperature is at least 21°C |
|
|
Term
Max and Min temp for Icing |
|
Definition
|
|
Term
|
Definition
Maximum load on main generator 400 A Maximum Load on APU Generator: Up to 30000 ft 400 A Above 30000 ft 300 A Maximum battery temperature 70°C |
|
|
Term
|
Definition
Maximum differential pressure 7.8 psi Maximum differential overpressure 8.1 psi Maximum differential negative pressure -0.3 psi |
|
|
Term
Weight
135
MZFW
MTOW
MLW
145
MZFW
MTOW
MLW |
|
Definition
135
MZFW - 16 000kg
MTOW - 20 000kg
MLW - 18 500kg
145
MZFW - 17 100kg
MTOW - 21 100kg
MLW - 18 700kg |
|
|
Term
Flap extension
Vfe
9°
18°
22°
45° |
|
Definition
9° - 250kts (240kts)
18° - 200kts (190kts)
22° - 200kts (190kts)
45° - 145kts (140kts) |
|
|
Term
|
Definition
|
|
Term
|
Definition
|
|
Term
Fuel
Total
Per wing
All Pumps working
No pumps working
Temps |
|
Definition
Fuel
5188
2954
18kg Unusable
165kg Unusable
-40°C -> 52°C |
|
|
Term
Power Plant Starter Limits
ON GROUND
Starting or Dry motoring - up to 5Mins ON, 5mins OFF
OR
1st to 4th cycles - 1min ON, 1min OFF
Following cycles
1Min ON, 5Mins OFF
IN FLIGHT
Max continuous Operation Time
5mins (No Cool Down period needed) |
|
Definition
Power Plant Starter Limits |
|
|
Term
|
Definition
|
|
Term
|
Definition
|
|